14 ELECTRICAL SYSTEM
76
102223-10
Main work
–
Check the battery voltage.
» Battery voltage: < 9 V
–
Do not charge the battery.
–
Replace the battery and dispose of the old battery properly.
» If the specifications have been met:
Battery voltage:
≥
9 V
–
Recharge the battery.
Guideline
The charging current, charging voltage, and charging time must not be
exceeded.
Maximum charging voltage
14.4 V
Maximum charging current
3.0 A
Charge the battery regularly when
the motorcycle is not in use
6 months
Info
Never remove cover
.
–
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (81229074000)
You can also use the battery charger to test the open-circuit voltage and start
potential of the battery, and to test the alternator. With this device, you cannot
overcharge the battery. The charging time may be longer at low temperatures.
–
Switch off the battery charger after charging and disconnect from the battery.
Finishing work
–
Install the battery.
–
Mount the seat. (
–
Install the air filter box cover. (
14.4
Changing the main fuse
Warning
Fire hazard
Incorrect fuses overload the electrical system.
–
Only use fuses with the required ampere value.
–
Do not bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle. It is located in the starter relay housing under the seat.
Preparatory work
–
Switch off all power consumers and switch off the engine.
–
Remove the air filter box cover. (
–
Remove the seat. (
F00069-10
Main work
–
Pull starter relay
from the holder.