21 TROUBLESHOOTING
144
Faults
Possible cause
Action
White smoke emission (steam
in exhaust gas)
Damaged cylinder head or
cylinder head gasket
–
Check the cylinder head and cylinder
head gasket.
Gear oil exits at the vent hose
Too much gear oil added
–
Check the gear oil level. (
Water in the gear oil
Damaged radial shaft seal ring
or water pump
–
Check the radial shaft seal ring and
the water pump.
Malfunction indicator lamp
lights up or flashes
Malfunction in the electronic
fuel injection
–
Check wiring for damage and electri-
cal plug-in connectors for corrosion
and damage.
–
Read out the fault memory using the
Husqvarna Motorcycles diagnostics
tool.
12-V battery discharged
The 12-V battery is not being
charged by the alternator
–
Check the charging voltage.
–
Check the stator winding of the alter-
nator.
Unwanted electrical power
consumer
–
Check the open-circuit current.
Values in combination
instrument deleted (time, stop
watch, lap times)
The combination instrument
battery is empty
–
Change combination instrument bat-
tery. (