46 – English
SETTINGS
Max-/min current
Max./min. current indicates the current interval that controls the prop. valve. A too high minimum value means that the
valve opens rapidly. This might mean that it is not possible to employ a function gently.
A low minimum value will increase the deadband of the control lever around the central position.
A low maximum value means that the valve does not open entirely and that the function cannot be run at maximum
speed.
A high maximum value means that the valve’s maximum opening position is achieved more rapidly. This will impair
resolution of the movement.
Boom pressure
The Boom pressure can be decreased from the maximum 200 bar to 150 bar. The pressure changes with 5 bar intervals.
Machine types
Indicates which machine type the remote control is linked to. This setting must be made when updating the software or
replacing the control module etc. Press the selection key to confirm the choice.
Languages
Setting for which language should be shown in the display. Press the selection key to confirm the choice.
To return to the factory default language, english. Keep the selection key for Work mode button while turning the main
switch until you see the main menu.
Joystick setup
Settings to adjust thumb switch behavior.
•
OFF - sets thumb switch inactive.
•
Auto - if Extra 1 is active, right thumb switch will control it. Otherwise it will have the same function as the top switch.
If Extra 2 is active, left thumb switch will control it. Otherwise it will have the same function as the top button.
•
Extra 1/Extra 2 - The thumb switch will only control Extra 1/Extra 2. If extra function is deactivated, the thumb switch
will be deactivated.
•
Tool - (only valid for left joystick) - Thumb switch on left joystick will control the tool function.
Joysticks
Settings for adjusting the function of the control levers.
Deadband
Deadband indicates the position in which the joysticks start to be activated. The higher the value the farther out from
neutral position that the joysticks are activated.
Precision
Settings to adjust the precision.
•
Default precision - standard setting.
•
Enhanced precision at high speed - typically used when a high and even speed is essential through out the entire
joystick movement, e.g. when digging.
•
Enhanced precision at low speed - typically used when high precision at low speed is essential e.g. when working
with precision tools such as Grappler or Steel Shear (MG 100/200 or DSS200).
Содержание DXR-310
Страница 75: ...English 75 TECHNICAL DATA Range and transport diagram DXR250 4483 176 5 2020 79 5 4815 189 5 ...
Страница 77: ...English 77 TECHNICAL DATA DXR270 4483 176 1986 78 4849 191 1435 56 ...
Страница 79: ...English 79 TECHNICAL DATA DXR300 4868 192 2368 93 5231 206 1818 72 ...
Страница 81: ...English 81 TECHNICAL DATA DXR310 5182 204 2129 84 2678 105 5549 218 ...
Страница 84: ...1158619 27 z Z 78 z Z 78 2016 12 19 US Original instructions ...