English –
35
TANK UNIT
Replacing the tank ventilator, oil tank
1.
Pull out the ventilator's rubber fastener using a pair of
pliers.
2.
Fit a new pin, vyon-plug and valve in a new rubber fastener,
place the unit in the hole in the tank from the outside.
Replacing the pulse tube
1.
Pull out the old pulse tube using a pair of pliers.
3.
Pull in the ventilator with fitted vyon-plug and pin using a
pair of long-nosed pliers from inside the tank.
2.
Insert a new pulse tube from the carburettor side and
carefully pull it in from the engine side.
Eng 33-44
97-12-03, 16.29
35