TROUBLESHOOTING

Problem

Possible Cause

Solution

Compressor will not run

Loss of power or overheating

No electrical power

Blown shop/house fuse
Shop/house breaker open

Thermal overload open
Pressure switch bad
Tank is full of air

Check for proper use of extension 
cord
Check to be sure unit is plugged in 
Check fuse/breaker or motor over-
load
Replace shop/house blown fuse
Reset shop/house breaker, determin-
ing why problem happened
Motor will restart when cool
Replace pressure switch
Compressor will turn on when tank 
pressure drops to cut-in pressure

Motor hums but cannot run or runs 
slowly

Low voltage
Wrong gauge wire or length of exten-
sion cord
Shorted or open motor winding
Defective check valve or unloader

Check with voltmeter
Check for proper gauge wire and 
cord length
Take compressor to service center
Take compressor to service center

Fuses blow/circuit breaker trips 
repeatedly

Incorrect size fuse, circuit overload

Wrong gauge wire or length of exten-
sion cord
Defective check valve or under loader

Check for proper fuse, use time-
delay fuse, disconnect other electri-
cal appliances from circuit or operate 
compressor on its own branch circuit
Check for proper gauge wire and 
cord length
Take compressor to service center

Thermal overload protector cuts out 
repeatedly

Low voltage
Lack of proper ventilation/room tem-
perature too high
Wrong gauge wire or length of exten-
sion cord

Check with voltmeter
Move compressor to well-ventilated 
area
Check for proper gauge wire and 
cord length

Air receiver pressure drops when 
compressor shuts off

Loose connections (fittings, tubing, 
etc.)
Loose drain valve
Check valve leaking

Check all connections with soap and 
water solution and tighten
Tighten drain valve
Take compressor to service center

      DANGER:

Do  not  disassemble  check  valve 
with air in tank — bleed tank.

Excessive moisture in discharge air

Excessive water in air tank
High humidity

Drain tank
Move to area of less humidity; use air 
line filter

Compressor runs continuously

Defective pressure switch
Excessive air usage

Take compressor to service center
Decrease air usage; compressor not 
large enough for tool’s requirement

Compressor vibrates

Loose mounting bolts

Tighten mounting bolts

Air output lower than normal

Broken inlet valves
Connections leaking

Take compressor to service center
Tighten connections

Содержание H1506F

Страница 1: ...y ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the op...

Страница 2: ...or pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D...

Страница 3: ...l safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any...

Страница 4: ...ust be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress t...

Страница 5: ...this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rul...

Страница 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Страница 7: ...beginning power tool operation always wear safety goggles safety glasses with side shields or a full face shield when needed We recommend Wide Vision Safety Mask for use over eyeglasses or standard sa...

Страница 8: ...cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension co...

Страница 9: ...within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed a...

Страница 10: ...Input 120 V 60 Hz AC only 12 Amps Net Weight 40 8 lbs COIL HOSE INFLATION NOZZLE INFLATION NOZZLE INFLATION ADAPTER INFLATION NEEDLE AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER MANUAL O...

Страница 11: ...been shipped completely assembled n Carefully remove the tool and any accessories from the box Make sure that all items listed in the packing list are included n Inspect the tool carefully to make sur...

Страница 12: ...Check and tighten all bolts fittings etc n Turn the pressure regulator knob fully clockwise to open the air flow Turn the locking nut clockwise to lock n Place the switch in the OFF position and plug...

Страница 13: ...o before chang ing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury n Rotate regulator knob fully clockwise to open air flow Tu...

Страница 14: ...s personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand...

Страница 15: ...in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WA...

Страница 16: ...isconnect other electri cal appliances from circuit or operate compressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload prote...

Страница 17: ...cified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc pr...

Страница 18: ...inent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the a...

Отзывы: