TANK 

PRESSURE

GAUGE

n

  Insert thread end of hose into open end of air outlet fit-

ting. Use open-end wrench to tighten securely.

 

NOTE:

  Be careful not to allow threads to become 

cross-threaded.

n

  Attach quick coupler to open end of hose and tighten 

securely. 

WARNING:

Do not attach air chuck or other tool to the open end of 
the hose until start-up has been completed.

n

  Firmly grasp the open end of the hose; hold facing 

away from yourself and others.

BREAKING IN THE PUMP

See Figures 6 - 7.

n

  Check and tighten all bolts, fittings, etc.

n

  Turn the pressure regulator knob fully clockwise to 

open the air flow. Turn the locking nut clockwise to 
lock.

n

  Place the switch in the 

OFF 

position and plug in the 

power cord.

n

  Open the drain valve completely.

n

  Turn the air compress 

ON ( l ) 

and run the air compres-

sor for 10 minutes to break in pump parts.

n

  Place the switch in the 

OFF 

position.

n

  Close the drain valve.

Fig. 6

Fig. 7

60

40

80

4

6

2

10

12

bar

psi

100

120

14

0

60

40

80

4

6

2

10

12

bar

psi

100

120

14

0

ON/OFF 

SWITCH

SAFETY 

VALVE

PRESSURE

REGULATOR KNOB

REGULATOR 

PRESSURE GAUGE

AIR 

OUTLET

DRAIN 

VALVE

ASSEMBLY

AIR OUTLET FITTING

HOSE

Fig. 4

Fig. 5

COUPLER

HOSE

LOCKING

NUT

Содержание H1506F

Страница 1: ...y ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the op...

Страница 2: ...or pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D...

Страница 3: ...l safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any...

Страница 4: ...ust be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress t...

Страница 5: ...this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rul...

Страница 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Страница 7: ...beginning power tool operation always wear safety goggles safety glasses with side shields or a full face shield when needed We recommend Wide Vision Safety Mask for use over eyeglasses or standard sa...

Страница 8: ...cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension co...

Страница 9: ...within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed a...

Страница 10: ...Input 120 V 60 Hz AC only 12 Amps Net Weight 40 8 lbs COIL HOSE INFLATION NOZZLE INFLATION NOZZLE INFLATION ADAPTER INFLATION NEEDLE AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER MANUAL O...

Страница 11: ...been shipped completely assembled n Carefully remove the tool and any accessories from the box Make sure that all items listed in the packing list are included n Inspect the tool carefully to make sur...

Страница 12: ...Check and tighten all bolts fittings etc n Turn the pressure regulator knob fully clockwise to open the air flow Turn the locking nut clockwise to lock n Place the switch in the OFF position and plug...

Страница 13: ...o before chang ing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury n Rotate regulator knob fully clockwise to open air flow Tu...

Страница 14: ...s personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand...

Страница 15: ...in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WA...

Страница 16: ...isconnect other electri cal appliances from circuit or operate compressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload prote...

Страница 17: ...cified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc pr...

Страница 18: ...inent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the a...

Отзывы: