background image

INSTALLATION OF EXTENDED AISLE SHIELD

STEP 1: ATTACH ANGLE BRACKET AND FLAT BAR

STEP 1: ATTACH ANGLE BRACKET AND FLAT BAR

STEP 1: ATTACH ANGLE BRACKET AND FLAT BAR

STEP 1: ATTACH ANGLE BRACKET AND FLAT BAR

ANGLE 
BRACKET

FLAT BAR

ATTACH ANGLE BRACKETS TO THE AISLE SHIELD 
PANEL AT THE TOP REINFORCING FLUTES ON EACH 
SIDE USING ¼” BOLT AND NUT AS SHOWN IN THE 
ABOVE PICTURE. DO THIS FOR BOTH SIDES OF THE 
PANEL.

ATTACH FLAT BARS TO THE ANGLE BRACKETS ON 
EACH SIDE USING 3/8” BOLT AND NUT AS SHOWN 
IN THE PICTURE ABOVE.

6

Содержание AISLE SHIELD

Страница 1: ...AISLE SHIELD INSTALLATION INSTRUCTIONS 6146 DENVER INDUSTRIAL PARK RD DENVER NC 28037 1 800 438 5629 www huskyrackandwire com 1 ...

Страница 2: ...NEL TAKE ONE OF EACH EYE BOLT 3 8 REGULAR NUT 3 8 PLAIN WASHER 3 8 LOCK TAKE ONE OF EACH EYE BOLT 3 8 REGULAR NUT 3 8 PLAIN WASHER 3 8 LOCK WASHER AND 3 8 NYLOK NUT INSERT REGULAR NUT PLAIN WASHER LOCK WASHER AND NYLOCK NUT RESPECTIVLEY IN THAT ORDER AS SHOWN IN THE EYEBOLT PICTURE TO THE LEFT MEASURE DESIRED OFFSET DISTANCE USING TAPE MEASURE MEASURE FROM BOTTOM OF THE LOCK WASHER TO CENTER OF TH...

Страница 3: ...UST SIT UNDERNEATH THE HORIZONTAL WIRE AND THE GAP IN THE EYE BOLT MUST FACE OUTWARD FROM THE PANEL WITH ONE PERSON ON EACH END OF THE PANEL LIFT THE PANEL TO ATTACH TO THE RACK POST PANEL LIFT THE PANEL TO ATTACH TO THE RACK POST INSERT THE TOP EYE BOLTS IN THE DESIRED HOLES ON THE RACK POST KEEPING THE LOCK WASHER AND NYLOCK NUT INSIDE OF THE RACK POST HAND TIGHTEN THE REGULAR NUT FROM THE OUTSI...

Страница 4: ... OF HARDWARE IS REQUIRED PER PANEL FOR 3 TALL PANELS FOUR 4 SETS OF HARDWARE IS REQUIRED PER PANEL FLAT BRACKET 1 WIDE X 5 LONG WITH TWO HOLES SLOTTED BACK UP PLATE FLAT BRACKET SLOTTED BACK UP PLATE X HEX HEAD BOLT NUT 3 8 X 2 CARRAIGE BOLT 3 8 NUT 1 SPACER AS SHOWN IN THE PICTURE ATTACH THE FLAT BRACKET TO THE PANEL USING BACK UP PLATE AND BOLT AND NUT ATTACH ALL PROVIDED FLAT BRACKETS TO THE PA...

Страница 5: ...RRIAGE BOLT TO THE OTHER END OF THE FLAT BRACKET USE 1 PLASTIC SPACER BETWEEN THE BRACKET AND RACK POST ATTACH 3 8 BOLTS TO ALL OF THE FLAT BRACKETS PROVIDED WITH ONE PERSON ON EACH END OF THE PANEL LIFT THE PANEL TO ATTACH TO THE RACK 1 SPACER PANEL LIFT THE PANEL TO ATTACH TO THE RACK POST INSERT THE HEAD OF THE BOLT THROUGH THE UPRIGHT POST HOLE TIGHTEN THE 3 8 NUT USING A WRENCH 5 ...

Страница 6: ...LAT BAR STEP 1 ATTACH ANGLE BRACKET AND FLAT BAR ANGLE BRACKET FLAT BAR ATTACH ANGLE BRACKETS TO THE AISLE SHIELD PANEL AT THE TOP REINFORCING FLUTES ON EACH SIDE USING BOLT AND NUT AS SHOWN IN THE ABOVE PICTURE DO THIS FOR BOTH SIDES OF THE PANEL ATTACH FLAT BARS TO THE ANGLE BRACKETS ON EACH SIDE USING 3 8 BOLT AND NUT AS SHOWN IN THE PICTURE ABOVE 6 ...

Страница 7: ... THE RACK POST STEP 2 ATTACH FLAT BAR TO THE RACK POST ATTACH THE OTHER END OF THE FLAT BAR TO THE RACK POST USING 3 8 BOLT AND NUT NOTE FOR FLUSH MOUNT RACK GUARD THE FLAT BAR IS ATTACHED TO THE POST THAT IS AWAY FROM THE AISLE SHIELD PANEL FOR OFFSET MOUNT AISLE SHIELD THE FLAT BAR IS ATTACHED TO THE NEAREST POST TO THE AISLE SHIELD PANEL 7 ...

Страница 8: ...B13 8 ...