Husky Air Compressor warranted by DAPC

DeVilbiss Air Power Company warrants to the original purchaser who uses the product in a consumer
application (personal, residential or household usage) that all products covered under this warranty
are free from defects in material and workmanship for one year from the date of purchase. All
products covered by this limited warranty which are used in commercial applications (i.e., income
producing) are warranted to be free of defects in material and workmanship for 90 days from the date
of original purchase. Products covered under this warranty include air compressors, air tools, service
parts, pressure washers, and generators.
DeVilbiss Air Power Company will repair or replace, at DeVilbiss' option, products or components
which have failed within the warranty period.  Service will be scheduled according to the normal work
flow and business hours at the service center location, and the availability of replacement parts. All
decisions of DeVilbiss Air Power Company with regard to this limited warranty shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state
to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (initial User):

• To process a warranty claim on this product, DO NOT return it to the retailer. The product must be

evaluated by an Authorized Warranty Service Center. For the location of the nearest Authorized
Warranty Service Center call 1-800-888-2468, 24 hours a day, 7 days a week or visit our web site
at devap.com.

• Retain original cash register sales receipt as proof of purchase for warranty work.
• Use reasonable care in the operation and maintenance of the product as described in the Owners

Manual(s).

• Deliver or ship the product to the nearest Authorized Warranty Service Center. Freight costs, if any,

must be paid by the purchaser.

• Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation. Contact

the nearest Authorized Warranty Service Center that provides on-site service calls for service call
arrangements.

• If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center,

the purchaser should contact DeVilbiss Air Power Company.

THIS WARRANTY DOES NOT COVER:

• Merchandise sold as reconditioned, used as rental equipment, or floor or display models.
• Merchandise that has become damaged or inoperative because of ordinary wear, misuse*, cold,

heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident,
failure to operate the product in accordance with the instructions provided in the Owners Manual(s)
supplied with the product, improper maintenance, the use of accessories or attachments not
recommended by DeVilbiss Air Power Company, or unauthorized repair or alterations. 
* An air compressor that pumps air more than the recommended duty cycle during a one hour
period may be considered misuse. 

• Repair and transportation costs of merchandise determined not to be defective.
• Costs associated with assembly, required oil, adjustments or other installation and start-up costs.
• Expendable parts or accessories supplied with the product which are expected to become

inoperative or unuseable after a reasonable period of use, including but not limited to sanding
disks or pads, saw and shear blades, grinding stones, springs, chisels, nozzles, o-rings, air jets,
washers and similar accessories.

• Merchandise sold by DeVilbiss Air Power Company which has been manufactured by and identified

as the product of another company, such as gasoline engines. The product manufacturer's
warranty, if any, will apply.  

• ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT

MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT
COVERED BY THIS WARRANTY
. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you.

• IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL
PURCHASE. 
Some states do not allow limitations on how long an implied warranty lasts, so the
above limitations may not apply to you.

DeVilbiss Air Power Company

213 Industrial Drive • Jackson, TN 38301-9615 

Telephone:  1-800-888-2468

FAX:  1-800-888-9036

Содержание A05051

Страница 1: ...Part No A05051 Rev 0 07 26 04 READ AND SAVE THESE INSTRUCTIONS Air Compressor Operator s Manual Model No Y1010 ESPA OL 21 39 FRAN AIS 40 60 Questions 1 800 888 2468...

Страница 2: ...Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive ha...

Страница 3: ...r property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent...

Страница 4: ...lace the entire compressor Failure to properly drain condensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a fire extingu...

Страница 8: ...r is off air tank pressure drops as you continue to use your accessory average duty cycle be maintained that is the air compressor pump should not run more than 30 45 minutes in any given hour When th...

Страница 9: ...ry Kit To Assemble Female Tire Chuck 1 Assemble female tire chuck a to hose b and tighten securely with wrenches To Assemble Accessories 1 Attach the blow gun c to hose b Risk of unsafe operation If a...

Страница 10: ...NSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly groun...

Страница 11: ...essors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other elect...

Страница 12: ...ff the power Pressure Switch not shown The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pr...

Страница 13: ...with inflator deflator nozzles to prevent air from leaking out of inflatables with very large air inlets Drain Valve not shown The drain valve is located at the base of the air tank and is used to dra...

Страница 14: ...utlet pressure must never exceed the maximum pressure rating How to Use Telescopic Handle and Wheels for Easy Mobility 1 Press the release button and slide handle out until it locks into place 2 Pull...

Страница 15: ...outlet How to use High Flow Inflator Deflator Adapter Body 1 Assemble the high flow inflator deflator body as described in the Assembly section 2 Choose nozzle to be used to inflate or deflate NOTE Th...

Страница 16: ...the safety valve operates freely If the valve is stuck or does not operate smoothly contact a trained service technician To Drain Tank NOTICE Allow unit to cool before draining tank drain valve becom...

Страница 17: ...ense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 2 Store accessories in the accessory storage located on back of unit 3 Wrap the electr...

Страница 18: ...M CAUSE CORRECTION Pressure switch does not shut off motor when compressor reaches cut out pressure Pressure switch cut out too high Move Off Auto On switch to the Off position if the unit does not sh...

Страница 19: ...box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit Check for proper fuse Y...

Страница 20: ...ce call arrangements If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT...

Страница 21: ...amolado perforado u otras actividades de la construcci n contienen materiales qu micos conocidos en el Estado de California como causantes de c ncer defectos de nacimiento u otros da os del aparato re...

Страница 22: ...ra reducir el riesgo de incendio no permita que el compresor opere desatendido Mant ngase siempre alerta cada vez que el producto este funcionando Siempre desconecte del suministro el ctrico colocando...

Страница 23: ...las herramientas neum ticas pistolas rociadoras accesorios activados por aire cubiertas y otros objetos inflables puede causar su explosi n o ser arrojados pudiendo ocasionar serias lesiones PELIGRO...

Страница 24: ...n requerida por este producto debe ser efectuada por personal autorizado de los servicentros de acuerdo a los c digos el ctricos nacionales y locales Aseg rese que el circuito el ctrico al cual est co...

Страница 25: ...PELIGRO ADVERTENCIA Riesgo de Ca da Un compresor port til puede caerse de la mesa el banco de trabajo o del techo da ando al compresor y pudiendo resultar en serias lesiones o la muerte del operador...

Страница 26: ...Mantenga libre la zona de operaciones de persona alguna animales dom sticos y obst culos Mantenga alejados a los ni os del compresor de aire en todo momento No opere el producto cuando se encuentre f...

Страница 27: ...a a la cual el motor arranca autom ticamente se llama presi n m nima de corte Presi n m xima de corte Cuando un compresor de aire se enciende y comienza a funcionar la presi n de aire en el tanque com...

Страница 28: ...BE instalarse la boquilla de seguridad Boquilla de seguridad ENSAMBLAJE DE ACCESORIOS La unidad se provee con un juego de accesorios y un juego inflador desinflador seleccione el accesorio que necesit...

Страница 29: ...ci n proveyendo un conductor de escape para la corriente el ctrica Este compresor de aire debe estar adecuadamente conectado a tierra El compresor port til de aire est equipado con un cable que tiene...

Страница 30: ...ircuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a trav s de los ramales del circuito sea de 15 A 2 Que el circuito no sea utilizado para alimentar ningu...

Страница 31: ...do El interruptor de presi n permite el arranque autom tico del motor cuando la presi n del tanque disminuye por debajo del valor de la presi n de conexi n regulada en f brica El motor se detendr cuan...

Страница 32: ...uillas infladoras desinfladoras para evitar que el aire se fugue de los art culos inflables con boquilla grande de entrada aire V lvula de drenaje no mostrado La v lvula de drenaje se encuentra ubicad...

Страница 33: ...accesorios La presi n de salida del regulador jam s debe exceder los valores de m xima presi n especificados needle 4 Abra completamente la v lvula de drenaje sentido antihorario a fin de permitir la...

Страница 34: ...edo pulgar Uso del adaptador inflador desinflador de gran flujo 1 Instale este adaptador en la forma descrita en la secci n Ensamblaje 2 Seleccione la boquilla a usar para inflar o desinflar NOTA El a...

Страница 35: ...e o luego de cada uso Antes de cada uso 4 Colocar la unidad sobre bloques para levantarla del piso 5 Colocar un contenedor adecuado debajo de la unidad para colectar el agua 6 Inclinar la unidad levem...

Страница 36: ...drena el agua lo corroer y debilitar causando un riesgo de ruptura del tanque de aire 2 Guarde los accesorios en el compartimiento en la parte posterior de la unidad 3 Para guardar envuelva el cord n...

Страница 37: ...a Las conexiones de los tubos no est n suficientemente ajustadas Las conexiones pierden aire Golpeteo Ajustar los acoples donde se escuchen escapes de aire Inspeccionar los acoples expuestos con una s...

Страница 38: ...autom tico del circuito disparado Verifique la caja de fusibles observando la existencia de fusibles fundidos y sustit yalos en caso de necesidad Restablezca el interruptor autom tico No use un fusib...

Страница 39: ...n Comun quese con el servicentro de garant as autorizado m s cercano que d servicio a domicilio para hacer los arreglos Si el comprador no estuviese satisfecho con el servicio recibido del servicentr...

Страница 40: ...e facial ou respirateur homologu MSHA NIOSH bien ajust lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de s curit de base afin de r...

Страница 41: ...r le compresseur une distance d au moins 20 pieds 6 m de la zone de vaporisation Il peut s av rer n cessaire d utiliser un boyau suppl mentaire Entreposer les mati res inflammables dans un endroit s c...

Страница 42: ...ui risque de causer des dommages la propri t ou des blessures Porter toujours des lunettes de protection homologu es ANSI Z87 1 avec des crans lat raux lors de l utilisation du compresseur Ne jamais d...

Страница 43: ...de mise la terre Pr vention Risque Pr vention Risque L air obtenu directement du compresseur ne devrait jamais tre utilis comme source d air pour les tre humains Si l air produit par ce compresseur se...

Страница 44: ...apr s vente autoris Les pi ces mobiles telles que la poulie le volant moteur et la courroie peuvent entra ner des blessures graves si elles entrent en contact avec une partie du corps ou des v tements...

Страница 45: ...ndes du compresseur d air Gardez les personnes non autoris es les animaux de compagnie et les obstacles loign s de l aire de travail Gardez les enfants loign s du compresseur d air en tout temps N uti...

Страница 46: ...r d air nous vous recommandons de conserver un cycle de service moyen de 50 75 c est dire que la pompe du compresseur d air ne devrait pas fonctionner plus que 30 45 minutes dans une heure particuli r...

Страница 47: ...c b e d g f h 2 Fixez sur le pistolet vaporisateur le bec de s curit d le bec de gonflage effil g la pointe de soufflette en caoutchouc h ou l adaptateur pour le pistolet vaporisateur e REMARQUE pour...

Страница 48: ...air doit tre ad quatement mis la terre Ce compresseur d air portatif est dot d un cordon muni d un fil de mise la terre et d une fiche appropri e de mise la terre voir l illustration ci dessous La fic...

Страница 49: ...e Certains mod les de compresseur d air peuvent fonctionner sur un circuit de 15 amp res si les conditions suivantes sont satisfaites 1 la tension d alimentation au circuit de d rivation est de 15 A 2...

Страница 50: ...rtie Le manom tre de sortie indique la pression d air disponible la sortie du r gulateur Cette pression est contr l e par le r gulateur et est toujours inf rieure ou gale la pression du r servoir Desc...

Страница 51: ...nde ouverture d admission d air Robinet de vidange non illustr Le robinet de vidange est situ la base du r servoir d air et est utilis pour vidanger la condensation apr s chaque utilisation Avant le d...

Страница 52: ...air trop lev e conduit un risque dangereux d clatement V rifiez la pression nominale maximum du fabricant pour tous les outils pneumatiques et accessoires utilis s La pression de sortie du r gulateur...

Страница 53: ...1 Assemblez l adaptateur de gonflage d gonflage grand d bit tel que d crit dans la section Assemblage 2 S lectionnez la buse utiliser pour le gonflage ou le d gonflage REMARQUE L anneau d tanch it peu...

Страница 54: ...un risque de rupture du r servoir d air 8 Une fois la vidange de l eau termin e fermez le robinet de vidange tournez dans le sens des aiguilles d une montre Le compresseur d air peut maintenant tre ra...

Страница 55: ...tien du manuel Risque d clatement L eau dans le r servoir d air peut condenser Si le r servoir n est pas vidang l eau corrodera et affaiblira les parois du r servoir d air causant ainsi un risque d cl...

Страница 56: ...es ne sont pas assez serr s Resserrez les raccords l o on peut entendre l air s chapper V rifiez les raccords l aide d une solution d eau savonneuse Ne pas trop serrer Fuites d air aux raccords Fuites...

Страница 57: ...e pas Fusible saut ou coupe circuit d clench Rallonge de longueur ou de calibre inappropri Connexions lectriques desserr es Moteur d fectueux V rifiez s il y a un fusible saut dans la bo te fusibles e...

Страница 58: ...58 FR A05051 NOTES...

Страница 59: ...59 FR A05051 NOTES...

Страница 60: ...cas Tout acheteur qui n est pas satisfait de l intervention du Centre de service apr s vente agr est pri de communiquer directement avec DeVilbiss Air Power Company CETTE GARANTIE NE COUVRE PAS CE QUI...