Contents

 

Overview  

 

     

04

 

Utilisation  

 

     

05

 

Contents of box  

 

     

06

 

Utilisation (cont.)  

 

     

07

 

Explanation of symbols  

 

    

08

 

Introduction  

 

     

09

 

Layout  

 

      

10

 

Scope of delivery  

 

     

10

  

Intended use  

 

     

11

 

Safety information  

     

11

 

Technical data  

 

     

16

 

Before starting the equipment 

 

   

17

 

Assembling and operation  

 

    

17

 

Electrical connection  

 

    

19

 

Maintenance  

 

     

20

 

Storage  

 

      

22

 

Disposal and recycling  

 

    

22

 

Troubleshooting  

 

     

23

Original operating manual

Vers.No. 161205

MODEL:

HC520 04/2017

AFTER SALES SUPPORT

 

55946

 

 

1300 855 831

  

[email protected]

ALDI guarantees that our exclusive brand products are developed to our 

stringent quality specifications. If you are not entirely satisfied with this

 

product, please return it to the nearest ALDI store within 60 days from the 

date of purchase, for a full refund or replacement, or take advantage of our 

after sales support by calling the supplier’s Customer Service Hotline.

Made in China

WORKZONE TITANIUM®

 is a registered trademark of ALDI Stores

DISTRIBUTED BY:

ALDI STORES

 

1 SARGENTS ROAD

 

MINCHINBURY NSW 2770

 

www.aldi.com.au

5

YEARS

WARRANTY

Содержание PREMIUM HC520

Страница 1: ...5 MODEL HC520 04 2017 AFTER SALES SUPPORT 55946 1300 855 831 support scheppach com au ALDI guarantees that our exclusive brand products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to the nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales supp...

Страница 2: ...7 Utilisation C D F D1 D2 20 12 13 ...

Страница 3: ...ngs in themselves do not remove the risks and cannot replace correct actions for preventing accidents Read operator manual Before any use refer to the corresponding section in this user manual Important Hot parts Keep your distance Wear hearing protection Beware of electrical voltage Warning The equipment is remote controlled and may start up without warning Caution Before using for the first time...

Страница 4: ... you to get familiar with your compressor and fully utilise all of its functions The operating instructions contain important notes on how to work safely properly and economically with your machine and how to avoid dangers save repair costs reduce downtime and increase the reliability and working life of the machine In addition to the safety regulations contained herein you must in any case comply...

Страница 5: ...l drain plug 13 Compressor pump 14 Compressed air hose not included not scope of delivery 15 Air filter 16 Oil sealing plug 17 ON OFF switch 18 Oil level window 19 Safety valve 20 Overload switch 21 Oil filler opening 22 Screw 23 Washer 24 Spring washer 25 Nut 3 Scope of delivery Open the packaging and remove the compressor carefully Remove the packaging material as well as the packaging and trans...

Страница 6: ...perator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this Please note that our equipment has not been designed for use in commercial trade or industrial applications Our warranty will be voided if the equipment is used in commercial trade or industrial applications or for equivalent purposes 5 Safety information These operating instructions p...

Страница 7: ...hould always be followed to reduce the risk of fire electric shock and personal injury including the following Read all these instructions before attempting to operate this product and save these instructions Safe work 1 Keep the work area orderly Disorder in the work area can lead to accidents 2 Take environmental influences into account Do not expose electric tools to rain Do not use electric to...

Страница 8: ... connection cable of the electric tool regularly and have it replaced by a recognised specialist when damaged Check extension cables regularly and replace them when damaged 10 Pull the plug out of the outlet During non use of the electric tool or prior to maintenance and when replacing tools such as saw blades bits milling heads 11 Avoid inadvertent starting Make sure that the switch is switched o...

Страница 9: ...s and additional units listed in the operating instructions or recommended or specified by the manufacturer The use of mounted tools or accessories other than those recommended in the operating instructions or catalogue may place your personal safety at risk 17 Noise Wear ear muffs when you use the compressor 18 Replacing the power cable To prevent hazards leave the replacement of damaged power ca...

Страница 10: ...us liquids are processed wear protective filter units face guards Also adhere to the safety information provided by the manufacturers of such liquids The details and designations of the Ordinance on Hazardous Substances which are displayed on the outer packaging of the processed material must be observed Additional protective measures are to be undertaken if necessary particularly the wearing of s...

Страница 11: ...fore using Do not use the compressor with a damaged or rusty pressure vessel If you discover any damage then please contact the customer service workshop DO NOT LOSE THESE SAFETY INSTRUCTIONS 6 Technical data Mains connection 230 240 V 50 Hz Motor rating W 1800 Operating mode S1 Compressor speed 2850 min 1 Pressure vessel capacity in liters 50 Operating pressure approx 10 bar Theoretical intake ca...

Страница 12: ...ature from 5 C to 40 C There must be no dust acids vapors explosive gases or inflammable gases in the room The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas where work is conducted with sprayed water The oil level in the compressor pump has to be checked before putting the equipment into operation 8 Assembling and operation m Warning Prior to any ad...

Страница 13: ...tarting difficult or impossible 8 7 ON OFF switch Fig 3 Pull the ON OFF switch 17 upwards to switch on the compressor To switch off the compressor press the ON OFF switch down 8 8 Setting the pressure Fig 1 3 Use the pressure regulator 5 to set the pressure on the pressure gauge 6 The set pressure can be drawn from the quick lock coupling 7 The vessel pressure can be read off the pressure gauge 4 ...

Страница 14: ... points where connection cables are passed through windows or doors Kinks where the connection cable has been improperly fastened or routed Places where the connection cables have been cut due to being driven over Insulation damage due to being ripped out of the wall outlet Cracks due to the insulation ageing Such damaged electrical connection cables must not be used and are life threatening due t...

Страница 15: ...any spraying tools from the compressor before cleaning Do not clean the compressor with water solvents or the like 10 2 Maintenance work on the pressure vessel Fig 1 m Important To ensure a long service life of the pressure vessel 8 drain off the condensed water by opening the drain plug for condensation water 10 each time after using Release the vessel pressure first see 11 1 Open the drain screw...

Страница 16: ...e opening and collect the oil in a vessel If the oil does not drain out completely we recommend tilting the compressor slightly When the oil has drained out re fit the oil drain plug 12 Dispose of the old oil at a drop off point for old oil To fill in the correct quantity of oil make sure that the compressor stands on an even surface Fill new oil through the oil filler opening 21 until it comes up...

Страница 17: ...compressor and using the compressed air which is still left in the pressure vessel e g with a compressed air tool running in idle mode or with a blow out pistol 12 Disposal and recycling The packaging protects the compressor against damage during transport Packing materials are usually chosen depending on their environmental friendliness and disposal method and can therefore be recycled Returning ...

Страница 18: ...ut there is no pressure The non return valve 19 leaks The seals are damaged The drain plug for conden sation water 10 leaks Have a service center replace the non return valve 19 Check the seals and have any dam aged seals replaced by a service center Tighten the screw by hand Check the seal on the screw and replace if necessary The compressor starts pressure is shown on the pressure gauge but the ...

Страница 19: ...24 ...

Страница 20: ...respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired...

Страница 21: ...e recommend you save this data elsewhere prior to sending the product for repair You should also be aware that rather than repairing goods we may replace them with refurbished goods of the same type or use refurbished parts in the repair process Please be assured though refurbished parts or replacements are only used where they meet ALDI s stringent quality specifications If at any time you feel y...

Страница 22: ...2017 4 1 1 x Air Compressor 1 x Air Filter 15 2 x Supporting Foot 9 2 x Wheel 11 1 x Mounting Material 1 x Oil Drain Plug 16 1 x Transport Handle 1 1 x Instruction Manual 1 x Warranty Card 15 17 2 5 4 3 1 B 5 3 4 8 10 11 16 12 18 13 16 5 17 19 18 11 9 15 11 23 24 25 22 23 23 25 22 11 24 9 15 9d 9a 9b A 16 18 21 max min 2 4 3 5 6 7 8 9 10 11 9a 9 9d 9b 9c 9 7 6 1a 14 H I 19 ...