HÜRNER HST 300 Pricon 2.0 User’s Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
value at start, in any other case the upper limit depends
on the load value and is calculated as the current at start
plus 15%.
11.2.8 Emergency Off
The welding process has been interrupted by pressing the
STOP/RESET key.
11.2.9 Heater Coil Error
The dynamic current value during welding differs by more
than 15% from the required value, indicating a short-circuit
in the heater coil.
11.2.10 Power Supply Failure at Last Welding
The last welding is incomplete. The welding unit was dis-
connected from the power supply voltage while it was
in progress. To go on using the unit, this error has to be
acknowledged by pressing the STOP/RESET key (see also
Sect. 9.4).
12 Technical Specifications
Nominal Voltage
230 V
Frequency
50 Hz / 60 Hz
Power
2800 VA, 80% duty cy.
Ingress Protection
IP 54
Primary Current
max. 16 A
Ambient Temperature
– 20°C to + 60 °C (– 4°F to + 140°F)
Output Voltage
5 V - 48 V
Max. Output Current
130 A
Memory for Reports
20,000 welding reports
Data Interface Port
USB v 2.0 (480 mbit/s)
(see also the information on the data ports in Sect. 8)
Tolerances:
Temperature
± 5 %
Voltage
± 2 %
Current
± 2 %
Resistance
± 5 %
Operating Range
20 through 1600 mm