background image

Version July 2014

EN

 5

HST 300 aquatherm  2.0 User’s Manual

a q u a t h e r m   G m b H

Biggen 5

57439 Attendorn, Germany

Introduction

Dear Customer:

Thank you very much for purchasing our product. We are confident 
that it will meet your expectations.

The HST 300 aquatherm  2.0 Welding Unit is designed exclusively for 
welding plastic pipe fittings according to the electrofusion process. It 
represents the next generation of the tried and tested HST 300 series, 
featuring a broader range of functions.

The  product  was  manufactured  and  checked  according  to  state-of-
the-art  technology  and  widely  recognized  safety  regulations  and  is 
equipped with the appropriate safety features.

Before shipment, it was checked for operation reliability and safety. 
In the event of errors of handling or misuse, however, the following 
may be exposed to hazards:

 •  the operator’s health,
 •  the product and other hardware of the operator,
 •  the efficient work of the product.

All persons involved in the installation, operation, maintenance, and 
service of the product have to

 •  be properly qualified,
 •  operate the product only when observed,
 •  read carefully and conform to the User’s Manual before working 

with the product.

Thank you.

Safety Messages

2.1  Using the Correct Connection Terminal

Use the appropriate connection terminal that is compatible with the 
fitting type used. Be sure the contact is firmly established and do not 
use connection terminals or terminal adapters that are burnt or not 
designed for the intended use.

2.2   Improper Use of the Welding and Power Supply Cables

Do not carry the product by its cables and do not pull the power cord 
to unplug the unit from the socket. Protect the cables against heat, 
oil, and cutting edges.

2.3  Securing the Fitting and the Joint

Use  positioner  clamps  or  a  vice  to  secure  the  fitting  and  the  joint 
to  be  made  before  welding.  The  fitting  manufacturer’s  installation 
instructions,  local  and  national  regulations  have  to  be  respected  in 
all cases.

A welding process must never be repeated with the same fitting, since 
this may cause parts under power to be accessible to the touch.

2.4  Cleaning the Product

The product must not be sprayed with or immersed in water.

Содержание HST 300 aquatherm 2.0

Страница 1: ...ersion Juli 2014 Nieder Ohmener Str 26 35325 M cke Atzenhain 49 0 6401 91 27 0 49 0 6401 91 27 39 info huerner de http www huerner de H RNER SCHWEISSTECHNIK GmbH Biggen 5 57439 Attendorn 49 0 2722 950...

Страница 2: ......

Страница 3: ...8 5 2 Anschlie en des Fittings 8 5 3 Auswahl der Rohrdimension 8 5 4 Starten des Schwei vorgangs 8 5 5 Schwei prozess 8 5 6 Ende des Schwei vorgangs 9 5 7 Abbruch des Schwei vorgangs 9 5 8 Abk hlzeit...

Страница 4: ...Schwei vorgangs 11 8 2 1 Unterspannung 11 8 2 2 berspannung 11 8 2 3 Widerstandsfehler 11 8 2 4 Frequenzfehler 12 8 2 5 Spannungsfehler 12 8 2 6 Strom zu niedrig 12 8 2 7 Strom zu hoch 12 8 2 8 Not Au...

Страница 5: ...das Produkt nur unter Beaufsichtigung betreiben vor Inbetriebnahme des Produkts die Bedienungsanleitung genau beachten Vielen Dank 2 Sicherheitshinweise 2 1 Benutzung des richtigen Fitting Adapters V...

Страница 6: ...sachgem durch eine Kundendienstwerkstatt repariert oder aus gewechselt werden 2 8 Anschlussbedingungen 2 8 1 Am Netz Die Anschlussbedingungen der Energieversorger Unfallverh tungsvor schriften anwendb...

Страница 7: ...rsand Die Anlieferung des Produkts erfolgt in einer Transportkiste Das Produkt ist in dieser Kiste vor Feuchtigkeit und Umwelteinfl ssen gesch tzt auf zubewahren Der Versand des Produkts sollte nur in...

Страница 8: ...n des Fittings wird die Rohrdimension d h der Durchmesser des zu verschwei enden Werkst cks mit den Pfeiltasten und ausgew hlt Durch Bet tigen der START SET Taste wird der gew hlte Rohrdurchmesser f r...

Страница 9: ...en die Taste gedr ckt wird Es handelt sich um die Softwareversion und die Seriennummer des Ger ts Mit der STOP RESET Taste kann die Anzeige wieder geschlossen werden 6 2 Widerstandsmessung Nach Bet ti...

Страница 10: ...ersprache aufgerufen wird vgl Abschn 7 1 1 Datum Uhrzeit M bedeutet dass durch Bet tigen der MEN Taste das Untermen zum Stellen der Uhr aufgerufen wird vgl Abschn 7 1 2 Summer Lautst rke M bedeutet da...

Страница 11: ...wendet werden und muss zur Reparatur eingeschickt werden 8 1 6 Temperaturfehler Gemessene Umgebungstemperatur ist au erhalb des Arbeitsbereiches des Ger tes niedriger als 20 C 4 F oder h her als 60 C...

Страница 12: ...betr gt der obere Abschaltwert das 1 18 fache des Anfangswertes ansonsten ist die Obergrenze lastabh ngig und liegt 15 ber dem Anlaufstrom 8 2 8 Not Aus Der Schwei vorgang wurde mit der STOP RESET Ta...

Страница 13: ...ertrieb aquatherm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Deutschland Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Hersteller H RNER Schwei technik GmbH Nieder Ohmener Str 26...

Страница 14: ......

Страница 15: ...5 2 Connecting the Fitting 8 5 3 Selecting the Pipe Dimension 8 5 4 Starting the Welding Process 8 5 5 Welding Process 8 5 6 End of Welding 8 5 7 Aborted Welding Process 9 5 8 Cooling Time 9 5 9 Retu...

Страница 16: ...g Welding 11 8 2 1 Low Voltage 11 8 2 2 Overvoltage 11 8 2 3 Resistance Error 11 8 2 4 Frequency Error 12 8 2 5 Voltage Error 12 8 2 6 Low Current 12 8 2 7 Excess Current 12 8 2 8 Emergency Off 12 8 2...

Страница 17: ...tion maintenance and service of the product have to be properly qualified operate the product only when observed read carefully and conform to the User s Manual before working with the product Thank y...

Страница 18: ...repaired or replaced by an ap proved service shop 2 8 Power Supply Specifications 2 8 1 Mains Power Supply Utility suppliers wiring requirements occupational safety rules ap plicable standards and nat...

Страница 19: ...s box protects the product from humidity and environmental agents When sending the product it should be placed into the transport box at all times 4 Principles of Operation The HST 300 aquatherm 2 0 a...

Страница 20: ...hen the fitting is connected the pipe dimension i e the diameter of the parts that are going to be welded is selected using the arrow keys and By pressing the START SET key the selected dimension is a...

Страница 21: ...P RESET key 6 2 Measuring Resistance When the START SET key was pressed to initiate a welding process the resistance value of the fitting is measured and compared to the value that matches the entered...

Страница 22: ...can access a sub menu for setting the clock see Sect 7 1 2 Buzzer Volume M means that by pressing the MENU key the user can access a sub menu for setting the volume of the status buzzer see Sect 7 1 3...

Страница 23: ...o be sent to an approved shop for check and repair 8 1 6 Temperature Error The ambient temperature measured is outside the operating range of the welding unit i e below 20 C 4 F or over 60 C 140 F 8 1...

Страница 24: ...s the value at start in any other case the upper limit depends on the load value and is calculated as the current at start plus 15 8 2 8 Emergency Off The welding process has been interrupted by press...

Страница 25: ...erm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Germany Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Manufacturer H RNER Schweisstechnik Nieder Ohmener Str 26 Tel 49 0 6401 9127...

Страница 26: ......

Страница 27: ...udage 8 5 2 Raccordement du manchon au poste de soudage 8 5 3 S lection de la dimension du tube 8 5 4 D but du soudage 8 5 5 Proc dure de soudage 8 5 6 Fin du soudage 9 5 7 Interruption du soudage 9 5...

Страница 28: ...oudage 11 8 2 1 Tension insuffisante 11 8 2 2 Surtension 11 8 2 3 Erreur r sistance 11 8 2 4 Erreur fr quence 12 8 2 5 Erreur tension 12 8 2 6 Courant bas 12 8 2 7 Courant excessif 12 8 2 8 Arr t d ur...

Страница 29: ...d ment habilit es travailler avec le produit seulement quand il est surveill respecter les consignes donn es dans le manuel utilisateur du poste de soudage Merci beaucoup 2 Consignes de s curit 2 1 C...

Страница 30: ...ls de l appareil faire appel de pr f rence un atelier agr pour faire r parer ou remplacer les pi ces en question 2 8 Alimentation 2 8 1 Alimentation secteur Les exigences de c blage des distributeurs...

Страница 31: ...e faire r viser le produit au moins une fois par an 3 2 Transport Conservation Livraison Le produit vous est livr dans une bo te de transport Le produit devrait tre conserv dans cette bo te prot g des...

Страница 32: ...sont encrass s ou d grad s Apr s que le contact a t tabli entre le poste de soudage et le raccord traiter le texte Pas de contact dispara t cf l cran 2 5 3 S lection de la dimension du tube La s lecti...

Страница 33: ...cran Contacter raccord la touche est enfonc e Il s agit de la version du logiciel et du num ro de s rie du poste Cet cran se referme suite une action sur la touche STOP RESET 6 2 V rification de la r...

Страница 34: ...ui permet de choisir la langue des textes affich s et figurant dans les rapports voir la section 7 1 1 Date Heure M l action sur la touche MENU ouvre un sous menu qui permet de r gler l horloge intern...

Страница 35: ...xp di un atelier agr pour r paration 8 1 6 Erreur temp rature ambiante La temp rature ambiante relev e par l appareil n est pas conforme aux conditions requises c est dire inf rieure 20 C 4 F ou sup r...

Страница 36: ...s la valeur du courant au d marrage sinon la valeur maximale d pend de la charge et est sup rieure de 15 au courant au d marrage 8 2 8 Arr t d urgence Le soudage a t interrompu par une action sur la t...

Страница 37: ...therm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Allemagne Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Fabricant H RNER Schweisstechnik Nieder Ohmener Str 26 Tel 49 0 6401 9127...

Страница 38: ...ette d claration sont conformes aux normes et documents de normalisation suivants CE Konformit t CE Conformity Conformit CE Richtlinie 2004 108 EG Richtlinie 2006 95 EG Andere Normen Other Standards A...