SPECIFICATION SUMMARY:
Technical Specifications
(AC power supply)
AC Input Voltage, Frequency 47 - 63 Hz
AC Input Current (Maximum) 1.2A/115VAC
DC Output Voltage 15 Volts
DC Output Current 0 - 4 Amps
Rated Power 60 Watt
AC dock light power supplies are IP67 rated.
Maximum Operating Temperature 50 °C / 122 °F Typical
Technical Specifications
(DC)
DC Input Voltage 10.0 - 30 VDC
DC Input Current (Maximum) 3.2A @ 12v / 1.6A @ 24v
Wire Size Recommendations
Conductor Sizes (AWG) for 3% Voltage Drop
Length of conductor from source of current to the product and back to the source - in feet
Total
Currrent
on Circuit
10’
15’
20’
25’
30’
40’
50’
60’
5 amps
18
16
14
12
12
10
10
10
10 amps
14
12
10
10
10
8
6
6
15 amps
12
10
10
10
10
6
6
6
20 amps
10
10
8
6
6
6
4
4
All wiring must be carried out by a suitably trained/qualified electri-
cian using ABYC guidelines. With low voltage DC wiring the risk of
fire may be present if wiring is not correctly installed.
Vessel Installation Instructions:
• Select a mounting location best suited to your particular needs.
• Surface Mounting: Mark the position. It is good practice to use tape on the sur-
face to be drilled then drill the hole through the tape. This will avoid scratching/chip-
ping of the surrounding surface. Mount light at least 6” below the waterline.
• Trim Tab Mounting: Install your lights by removing the screws on the bottom of
each trim tab ram (Bennett), insert bracket and tighten screws. Brackets are uni-
versal for other planing systems. Ensure your tabs are completely in the down po-
sition when installing to allow for ample cord length.
• Fit wiring: Before proceeding to drill the above waterline wire holes, check care-
fully to ensure that it will not affect the operation of other equipment in close prox-
imity, nor compromise the integrity of the structure.
• After drilling the holes apply a marine grade sealant, 3M 5200 is recommended,
in the holes to ensure it is completely sealed against the ingress of moisture be-
tween lamination. Attach light and allow sealant to cure.
• Use either cable clams or apply a marine grade sealant to fill the holes to ensure
it is completely sealed against water intrusion.
• Use wire ties to ensure cables will not chafe or kink. Wire loom can be used for
barnacle protection.
• All wiring must be carried out by a suitably trained/qualified electrician using ABYC
guidelines. With low voltage DC wiring the risk of fire may be present if wiring is
not correctly installed.
• Ensure power supply wiring is of the correct size for the current draw.
Ensure
wire harness will not chafe.
• Use only approved marine grade water-tight
connectors and wire. All joints must be sol-
dered and sealed with a proprietary compound
filled heat shrink tube.
• Ensure electrical supply has suitably sized
fuse or other protective device to provide ade-
quate protection of wiring and connected
equipment in the event of circuit fault or short
circuit.
• Dismantling of this product voids warranty.
• Do not use as a step.
Hint:
Spraying lights with Silicone or putting
a thin layer of Petroleum Jelly on annually will
help keep algae, mussels, barnacles, etc. off.
Bennett Tabs