Hunter XC Скачать руководство пользователя страница 5

ENG

A – LCD Display

1.  

 

Run Times

 – Allows user to set each valve station run time 

from 1 minute to 4 hours. 

2.  

 

Start Times

 – Allows 1 to 4 start times to be set in each  

program.

3.   Station Number

 – Indicates currently selected station number.

4.   Program Designator

 – Identifies program (A, B, or C) in use.

5.    Day of the Week

 – Identifies day of the week 

6.  

Interval Watering

 – Identifies month when programming current date.

7.   Odd/Even Watering

 – Identifies if Odd or Even watering has been 

selected.

8.   Flashing Sprinkler

 – Indicates that watering is taking place.

9.  

 

System Off

 – Allows user to discontinue all programs and 

watering. Also allows the user to set the programmable “rain off” 

which stops watering for a period from 1 to 7 days.

10. 

 

Umbrella

 – Indicates that the rain sensor is active.

11. 

 

Seasonal Adjustment

 – Allows the user to make run time 

changes according to the seasons without reprogramming the 

controller. Bars on the left allow quick visual reference to the 

seasonal adjustment percentage.

12. 

 

Rain Drop

 – Indicates watering will occur on the selected day.

13. 

 Crossed Rain Drop

 – Indicates the watering will NOT occur on

 

the selected day.

14. 

Calendar

 – Indicates interval watering schedule has been  

programmed. Icon also appears when programming the current day.

B – Wiring Compartment

15. Lithium Battery

 – The replaceable lithium battery (included) allows 

the controller to be programmed in the absence of AC power. In 

addition, the battery will provide power for backup timekeeping in 

the event of a power outage.

16. Internal Junction Box

 – Junction box in outdoor models for  

making AC power connections.

17. Terminal Strip

 – Use to attach transformer, sensor, and valve wires from 

their source to the controller.

18. Reset Button

 – Use to reset the controller.

C – Control Buttons

  Button – Increases the selected item flashing in the display. 
  Button – Decreases the selected item flashing in the display.

  Button – Returns selected flashing display to previous item.
  Button – Advances the selected flashing display to the next item.
  Button – Selects program A, B or C for different watering zone 

requirements.

19. Sensor Bypass Switch.

 

Dial Settings

Run

 – Normal dial position for all controller automatic and manual 

operation.

 

Current Time/Day

 – Allows current day and clock time to be set.

 

Start Times

 – Allows 1 to 4 start times to be set in each program.

 

Run Times

 – Allows user to set each valve station run time from 1 

minute to 4 hours. 

 

Water Days

 – Allows the user to select interval days to water.

 

Seasonal Adjustment

 – Allows user to make run time changes ac-

cording to the seasons without reprogramming the controller. Bars 

on the left allow quick visual reference to the seasonal adjustment 

percentage.

1

 

Manual-One Station

 – Allows user to activate a one-time watering 

of a single valve.

ALL

 

Manual-All Stations

 – Allows user to activate a one-time watering 

of all valve stations or a few selected stations.

 

System Off

 – Allows user to discontinue all programs and water-

ing. Also allows the user to set the programmable rain off which 

stops watering for a period from 1 to 7 days.

D – External Transformer (Indoor Model only)

A plug in transformer is provided to supply AC power to the controller.

Содержание XC

Страница 1: ...rrigation Controller Owner s Manual and Programming Instructions RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC ...

Страница 2: ......

Страница 3: ...Station Run Times 8 Setting Days to Water 8 Selecting Specific Days of the Week to Water 8 Selecting Odd or Even Days to Water 8 Selecting Interval Watering 9 Setting Event Day s Off 9 Automatic Watering 9 System Off 9 Programmable Rain Off 9 Seasonal Adjustment 10 1 Manually Run a Single Station 10 ALL Manually Run All Stations 10 One Touch Manual Start and Advance 10 Advanced Features 11 Program...

Страница 4: ... TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION SEN C P 1 2 3 4 5 6 7 8 RST 24VAC BAT ACTIVE SENSOR BYPASS MO TU WE TH FR SA SU ODD EVEN AM PM 24HR 2 4 30 1 3 29 A C B D 17 18 13 2 3 9 11 4 6 10 5 12 1 7 8 14 15 Outdoor Model Internal Transformer Included Indoor Model XC COMPONENTS Note Plug may look different from Illu...

Страница 5: ...nt of a power outage 16 Internal Junction Box Junction box in outdoor models for making AC power connections 17 Terminal Strip Use to attach transformer sensor and valve wires from their source to the controller 18 Reset Button Use to reset the controller C Control Buttons Button Increases the selected item flashing in the display Button Decreases the selected item flashing in the display Button R...

Страница 6: ...wires to the appropriate station terminals and tighten their screws 5 Indoor Models route the transformer cable through the hole on the left side of the controller and connect the wires to the two screws marked 24VAC Outdoor Models transformer wires are already connected to the AC terminals so all that is required is to connect primary power to the junction box see below E High Voltage Wiring Outd...

Страница 7: ...ch the common wire to either solenoid wire of the valve Attach a separate control wire to the remaining solenoid wire PSR Series Pump Start Relay 4 5 Meters Minimum 15 ToPump RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC CONNECTING A PUMP START RELAY NOTE Complete this section only if you ha...

Страница 8: ... manually test proper operation of the rain sensor by running a manual all stations cycle or by activating the system using the One Touch Manual Start see page 10 During the Manual cycle pressing the test button on the Mini Clik will interrupt watering Manually Bypassing the Weather Sensor If the rain sensor is interrupting irrigation you can bypass it by using the bypass switch on the front of th...

Страница 9: ...OGRAM B PROGRAM C LOCATION 1 2 3 4 5 6 STATION STATION RUN TIME STATION RUN TIME STATION RUN TIME 1 2 3 4 PROGRAM START TIMES HUNTER XC NOTES DAY OF THE WEEK ODD EVEN OR INTERVAL MO TU WE TH FR SU SA WATERING SCHEDULE ...

Страница 10: ... be in the display The month will be flashing and the icon will be displayed Use the or buttons to change the month Press the button to proceed to setting the day 4 The day will be flashing and the icon will be displayed Use the or buttons to change the day Press the button to proceed to setting the time 5 The time will be displayed Use the and buttons to select AM PM or 24 hour Press the button t...

Страница 11: ...u can move back and forth from ODD to EVEN by pressing the and buttons NOTE The 31st of any month and February 29th are always off days if Odd watering is selected Eliminating a Program Start Time With the dial set to START TIMES position push the or button until you reach 12 00 AM Midnight From here push the button once to reach the OFF position Setting Station Run Times 1 Turn the dial to RUN TI...

Страница 12: ...ton to set this day as a no water day The will illuminate over this day 6 Repeat steps 4 and 5 until all desired event day s are off NOTE You also have the option in the interval watering schedule to program Odd or Even days off Automatic Watering After programming the XC set the dial to the RUN position to enable automatic execution of all selected watering programs and start times System Off Val...

Страница 13: ...reviously set program Also see One Touch Start and Advance Manually Run All Stations ALL 1 Turn dial to MANUAL ALL STATIONS position 2 Select program A B or C by pressing the button 3 Station run time will flash in the display Use the or button to select the amount of time for a station to water if different from the run time displayed 4 Use the button to move to the next station 5 Repeat steps 3 ...

Страница 14: ...at is running in the sensor override mode will flash the and icons alternately Test Program of All Stations The XC allows the user a simplified method for running a test pro gram This feature will operate each station in numerical sequence from the lowest to the highest 1 With the dial in the RUN position press and hold the button The station number will be displayed and the time will be flashing ...

Страница 15: ...ay Between Stations This feature allows the user to insert a delay between stations between when one station turns off and the next one turns on 1 Start with the dial in the RUN position 2 Press and hold the button down while turning the dial to the RUN TIMES position 3 Release the button At this point the display will show a delay time for all stations in seconds which will be flashing 4 Press th...

Страница 16: ...rammed to override the sensor Verify operation of rain sensor and proper wiring Remove jumper from the sensor terminals Reprogram the sensor override to enable the sensor see page 10 Frozen display or showing incorrect information Power surge Reset the controller per page 11 Clearing Controller Memory Resetting the Controller Display shows ERR with a number 1 8 Short in valve wiring circuit or fau...

Страница 17: ... included used for re mote programming and backup timekeep ing Use CR2032 3 volt Electronic short circuit protection Non volatile memory for program data UL Listed Model XC x00 has an IP24 Rating for Pollution Degree 4 Clean only with a cloth dampened with mild soap and water PROBLEM CAUSES SOLUTIONS Display shows a station is running but the and icons are flashing The sensor is interrupting irrig...

Страница 18: ...5 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a part...

Отзывы: