Hunter XC Скачать руководство пользователя страница 13

MANUAL-ONE STATION

1

MANUAL-ALL STATIONS

ALL

SEASONAL ADJUSTMENT

ENG

0

Seasonal Adjustment 

Seasonal Adjust is used to make global run time changes without 

re-programming the entire controller. To use the seasonal adjustment 

feature:
1.  Turn the dial to the 

SEASONAL  

ADJUSTMENT

 position.

2.  The display will now show a flashing number 

followed by a %, as well as the bar graph which 

always remains on the display. Press the   or   

button to adjust the percentage of the seasonal adjustment. Each 

bar on the graph represents 10%. This feature can adjust the con-

troller from 10% to 150% of the original program.

To view the adjusted run times, simply turn the dial to the 

RUN TIMES

 

position, the displayed run time will be updated accordingly as the 

seasonal adjustment is made.

NOTE: The controller should always be initially  

programmed in the 100% position.

Manually Run a Single Station 

1

1.  Turn dial to 

MANUAL – ONE STATION

 

position.

2.  Station run time will flash in the display. Use the   button to 

move to the desired station. You may use the   or   button to 

select the amount of time for a station to water.

3.  Turn the dial clockwise to the 

RUN

 position to run the station (only 

the designated station will water, then the controller will return to 

automatic mode with no change to the previously set program). 

Also see 

One Touch Start and Advance

.

Manually Run All Stations 

ALL

1.  Turn dial to 

MANUAL – ALL STATIONS

 

position.

2.  Select program A, B, or C by pressing the   button.
3.  Station run time will flash in the display. Use the   or   button 

to select the amount of time for a station to water if different from 

the run time displayed.

4.  Use the   button to move to the next station.
5.  Repeat steps 3 and 4 to customize each station.
6.  Press the   button until you reach the station at which you would 

like watering to begin. 

Turn the dial clockwise to the 

RUN

 position (the controller will water 

the entire program beginning with the station number last left in the 

display, then return to the automatic mode with no change in the 

previously set program).

One Touch Manual Start and Advance

You can also activate all stations to water without using the dial.
1.  Hold down the   button for 2 seconds.
2.  This feature automatically defaults to program A. You can select 

program B or C by pressing the   button.

3.  The station number will be flashing. Press the   button to scroll 

through the stations and use the   or   button to adjust station 

run times. (If no buttons are pressed for a few seconds during 

step 2 or 3, the controller will automatically begin watering).

4.  Press the   button scroll to the station you wish to begin with. 

After a 2 second pause, the program will begin. At any time during 

the manual cycle, you can use the 

 

or   buttons to navigate 

from station to station manually.

Содержание XC

Страница 1: ...rrigation Controller Owner s Manual and Programming Instructions RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC ...

Страница 2: ......

Страница 3: ...Station Run Times 8 Setting Days to Water 8 Selecting Specific Days of the Week to Water 8 Selecting Odd or Even Days to Water 8 Selecting Interval Watering 9 Setting Event Day s Off 9 Automatic Watering 9 System Off 9 Programmable Rain Off 9 Seasonal Adjustment 10 1 Manually Run a Single Station 10 ALL Manually Run All Stations 10 One Touch Manual Start and Advance 10 Advanced Features 11 Program...

Страница 4: ... TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION SEN C P 1 2 3 4 5 6 7 8 RST 24VAC BAT ACTIVE SENSOR BYPASS MO TU WE TH FR SA SU ODD EVEN AM PM 24HR 2 4 30 1 3 29 A C B D 17 18 13 2 3 9 11 4 6 10 5 12 1 7 8 14 15 Outdoor Model Internal Transformer Included Indoor Model XC COMPONENTS Note Plug may look different from Illu...

Страница 5: ...nt of a power outage 16 Internal Junction Box Junction box in outdoor models for making AC power connections 17 Terminal Strip Use to attach transformer sensor and valve wires from their source to the controller 18 Reset Button Use to reset the controller C Control Buttons Button Increases the selected item flashing in the display Button Decreases the selected item flashing in the display Button R...

Страница 6: ...wires to the appropriate station terminals and tighten their screws 5 Indoor Models route the transformer cable through the hole on the left side of the controller and connect the wires to the two screws marked 24VAC Outdoor Models transformer wires are already connected to the AC terminals so all that is required is to connect primary power to the junction box see below E High Voltage Wiring Outd...

Страница 7: ...ch the common wire to either solenoid wire of the valve Attach a separate control wire to the remaining solenoid wire PSR Series Pump Start Relay 4 5 Meters Minimum 15 ToPump RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC CONNECTING A PUMP START RELAY NOTE Complete this section only if you ha...

Страница 8: ... manually test proper operation of the rain sensor by running a manual all stations cycle or by activating the system using the One Touch Manual Start see page 10 During the Manual cycle pressing the test button on the Mini Clik will interrupt watering Manually Bypassing the Weather Sensor If the rain sensor is interrupting irrigation you can bypass it by using the bypass switch on the front of th...

Страница 9: ...OGRAM B PROGRAM C LOCATION 1 2 3 4 5 6 STATION STATION RUN TIME STATION RUN TIME STATION RUN TIME 1 2 3 4 PROGRAM START TIMES HUNTER XC NOTES DAY OF THE WEEK ODD EVEN OR INTERVAL MO TU WE TH FR SU SA WATERING SCHEDULE ...

Страница 10: ... be in the display The month will be flashing and the icon will be displayed Use the or buttons to change the month Press the button to proceed to setting the day 4 The day will be flashing and the icon will be displayed Use the or buttons to change the day Press the button to proceed to setting the time 5 The time will be displayed Use the and buttons to select AM PM or 24 hour Press the button t...

Страница 11: ...u can move back and forth from ODD to EVEN by pressing the and buttons NOTE The 31st of any month and February 29th are always off days if Odd watering is selected Eliminating a Program Start Time With the dial set to START TIMES position push the or button until you reach 12 00 AM Midnight From here push the button once to reach the OFF position Setting Station Run Times 1 Turn the dial to RUN TI...

Страница 12: ...ton to set this day as a no water day The will illuminate over this day 6 Repeat steps 4 and 5 until all desired event day s are off NOTE You also have the option in the interval watering schedule to program Odd or Even days off Automatic Watering After programming the XC set the dial to the RUN position to enable automatic execution of all selected watering programs and start times System Off Val...

Страница 13: ...reviously set program Also see One Touch Start and Advance Manually Run All Stations ALL 1 Turn dial to MANUAL ALL STATIONS position 2 Select program A B or C by pressing the button 3 Station run time will flash in the display Use the or button to select the amount of time for a station to water if different from the run time displayed 4 Use the button to move to the next station 5 Repeat steps 3 ...

Страница 14: ...at is running in the sensor override mode will flash the and icons alternately Test Program of All Stations The XC allows the user a simplified method for running a test pro gram This feature will operate each station in numerical sequence from the lowest to the highest 1 With the dial in the RUN position press and hold the button The station number will be displayed and the time will be flashing ...

Страница 15: ...ay Between Stations This feature allows the user to insert a delay between stations between when one station turns off and the next one turns on 1 Start with the dial in the RUN position 2 Press and hold the button down while turning the dial to the RUN TIMES position 3 Release the button At this point the display will show a delay time for all stations in seconds which will be flashing 4 Press th...

Страница 16: ...rammed to override the sensor Verify operation of rain sensor and proper wiring Remove jumper from the sensor terminals Reprogram the sensor override to enable the sensor see page 10 Frozen display or showing incorrect information Power surge Reset the controller per page 11 Clearing Controller Memory Resetting the Controller Display shows ERR with a number 1 8 Short in valve wiring circuit or fau...

Страница 17: ... included used for re mote programming and backup timekeep ing Use CR2032 3 volt Electronic short circuit protection Non volatile memory for program data UL Listed Model XC x00 has an IP24 Rating for Pollution Degree 4 Clean only with a cloth dampened with mild soap and water PROBLEM CAUSES SOLUTIONS Display shows a station is running but the and icons are flashing The sensor is interrupting irrig...

Страница 18: ...5 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a part...