Hunter XC Скачать руководство пользователя страница 12

SYSTEM OFF

RUN

RUN

SYSTEM OFF

PROGRAMMInG THE COnTROLLER (cont.)

Selecting Interval Watering

 

With this option you can select interval water-

ing from 1 to 31 days.
1.  With the cursor on 

EVEN

, press the

 

button once and the

 

 icon will appear and a 1 flashing in the 

display. Interval watering schedule appears on the display.

2.  Press the   or   button to select the number of days between 

watering days (from 1 to 31 days). This is called the interval.

The controller will water the selected program at the next start time 

and will then water at the interval programmed.

Setting Event Day(s) Off

The XC allows you to program a No Water Day(s). This feature is use-

ful to inhibit watering on specific day(s). For example, if you always 

mow the lawn on Saturdays, you would designate Saturday as a 

No 

Water Day

 so that you are not mowing wet grass. 

1.  Turn the dial to the 

WATER DAYS

 position.

2.  Enter an interval watering schedule as described on page 8.
3.  Press the  button to scroll to the 

No Water Days

 at the bottom of 

the display. 

MO

 will be flashing.

4.  Use the  button until the cursor is at the day of the week you 

wish to set as a No Water Day.

5.  Press the   button to set this day as a no water day. The   will 

illuminate over this day.

6.  Repeat steps 4 and 5 until all desired event day(s) are off.

NOTE: You also have the option in the interval watering 

schedule to program Odd or Even days off.

Automatic Watering 

After programming the XC, set the dial to the 

RUN

 position 

to enable automatic execution of all selected watering 

programs and start times.

System Off 

Valves currently watering will be shut off after the 

dial is turned to the 

SYSTEM OFF

 position for two 

seconds. All active programs are discontinued and 

watering is stopped. To return the controller to normal 

automatic operation, simply return the dial to the 

RUN

 position.

Programmable Rain Off

This feature permits the user to stop all programmed waterings for 

a designated period from 1 to 7 days. At the end of the programmed 

rain off period, the controller will resume normal 

automatic operation.
1.  Turn the dial to the 

SYSTEM OFF

 position.  

Wait for 

OFF

 to be displayed.

2.  Press the   button as many times as needed to 

set the number of days off (up to 7 days).

3.  Turn the dial back to the 

RUN

 position at which 

OFF

number

, the 

 and

icons will be displayed.

The days off remaining will decrease at midnight 

each day. When it goes to zero, the display will show 

normal time of day and normal irrigation will resume 

at the next scheduled start time.

Содержание XC

Страница 1: ...rrigation Controller Owner s Manual and Programming Instructions RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC ...

Страница 2: ......

Страница 3: ...Station Run Times 8 Setting Days to Water 8 Selecting Specific Days of the Week to Water 8 Selecting Odd or Even Days to Water 8 Selecting Interval Watering 9 Setting Event Day s Off 9 Automatic Watering 9 System Off 9 Programmable Rain Off 9 Seasonal Adjustment 10 1 Manually Run a Single Station 10 ALL Manually Run All Stations 10 One Touch Manual Start and Advance 10 Advanced Features 11 Program...

Страница 4: ... TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION SEN C P 1 2 3 4 5 6 7 8 RST 24VAC BAT ACTIVE SENSOR BYPASS MO TU WE TH FR SA SU ODD EVEN AM PM 24HR 2 4 30 1 3 29 A C B D 17 18 13 2 3 9 11 4 6 10 5 12 1 7 8 14 15 Outdoor Model Internal Transformer Included Indoor Model XC COMPONENTS Note Plug may look different from Illu...

Страница 5: ...nt of a power outage 16 Internal Junction Box Junction box in outdoor models for making AC power connections 17 Terminal Strip Use to attach transformer sensor and valve wires from their source to the controller 18 Reset Button Use to reset the controller C Control Buttons Button Increases the selected item flashing in the display Button Decreases the selected item flashing in the display Button R...

Страница 6: ...wires to the appropriate station terminals and tighten their screws 5 Indoor Models route the transformer cable through the hole on the left side of the controller and connect the wires to the two screws marked 24VAC Outdoor Models transformer wires are already connected to the AC terminals so all that is required is to connect primary power to the junction box see below E High Voltage Wiring Outd...

Страница 7: ...ch the common wire to either solenoid wire of the valve Attach a separate control wire to the remaining solenoid wire PSR Series Pump Start Relay 4 5 Meters Minimum 15 ToPump RUN TIMES CURRENT TIME DAY WATER DAYS START TIMES RUN SEASONAL ADJUSTMENT ALL MANUAL ALL STATIONS SYSTEM OFF 1 MANUAL ONE STATION ACTIVE SENSOR BYPASS XC CONNECTING A PUMP START RELAY NOTE Complete this section only if you ha...

Страница 8: ... manually test proper operation of the rain sensor by running a manual all stations cycle or by activating the system using the One Touch Manual Start see page 10 During the Manual cycle pressing the test button on the Mini Clik will interrupt watering Manually Bypassing the Weather Sensor If the rain sensor is interrupting irrigation you can bypass it by using the bypass switch on the front of th...

Страница 9: ...OGRAM B PROGRAM C LOCATION 1 2 3 4 5 6 STATION STATION RUN TIME STATION RUN TIME STATION RUN TIME 1 2 3 4 PROGRAM START TIMES HUNTER XC NOTES DAY OF THE WEEK ODD EVEN OR INTERVAL MO TU WE TH FR SU SA WATERING SCHEDULE ...

Страница 10: ... be in the display The month will be flashing and the icon will be displayed Use the or buttons to change the month Press the button to proceed to setting the day 4 The day will be flashing and the icon will be displayed Use the or buttons to change the day Press the button to proceed to setting the time 5 The time will be displayed Use the and buttons to select AM PM or 24 hour Press the button t...

Страница 11: ...u can move back and forth from ODD to EVEN by pressing the and buttons NOTE The 31st of any month and February 29th are always off days if Odd watering is selected Eliminating a Program Start Time With the dial set to START TIMES position push the or button until you reach 12 00 AM Midnight From here push the button once to reach the OFF position Setting Station Run Times 1 Turn the dial to RUN TI...

Страница 12: ...ton to set this day as a no water day The will illuminate over this day 6 Repeat steps 4 and 5 until all desired event day s are off NOTE You also have the option in the interval watering schedule to program Odd or Even days off Automatic Watering After programming the XC set the dial to the RUN position to enable automatic execution of all selected watering programs and start times System Off Val...

Страница 13: ...reviously set program Also see One Touch Start and Advance Manually Run All Stations ALL 1 Turn dial to MANUAL ALL STATIONS position 2 Select program A B or C by pressing the button 3 Station run time will flash in the display Use the or button to select the amount of time for a station to water if different from the run time displayed 4 Use the button to move to the next station 5 Repeat steps 3 ...

Страница 14: ...at is running in the sensor override mode will flash the and icons alternately Test Program of All Stations The XC allows the user a simplified method for running a test pro gram This feature will operate each station in numerical sequence from the lowest to the highest 1 With the dial in the RUN position press and hold the button The station number will be displayed and the time will be flashing ...

Страница 15: ...ay Between Stations This feature allows the user to insert a delay between stations between when one station turns off and the next one turns on 1 Start with the dial in the RUN position 2 Press and hold the button down while turning the dial to the RUN TIMES position 3 Release the button At this point the display will show a delay time for all stations in seconds which will be flashing 4 Press th...

Страница 16: ...rammed to override the sensor Verify operation of rain sensor and proper wiring Remove jumper from the sensor terminals Reprogram the sensor override to enable the sensor see page 10 Frozen display or showing incorrect information Power surge Reset the controller per page 11 Clearing Controller Memory Resetting the Controller Display shows ERR with a number 1 8 Short in valve wiring circuit or fau...

Страница 17: ... included used for re mote programming and backup timekeep ing Use CR2032 3 volt Electronic short circuit protection Non volatile memory for program data UL Listed Model XC x00 has an IP24 Rating for Pollution Degree 4 Clean only with a cloth dampened with mild soap and water PROBLEM CAUSES SOLUTIONS Display shows a station is running but the and icons are flashing The sensor is interrupting irrig...

Страница 18: ...5 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications However there is no guarantee that interference will not occur in a part...

Отзывы: