27
Problem
Causes
Solutions
The controller is continuously watering
Too many start times have been
programmed
Only one start time is necessary to activate a program
(refer to Setting the Program Start Times on page 18)
There is no display
Check AC power wiring
Correct any errors
The display reads “No AC”
There is no AC power present (the
controller is not receiving any power)
Check to see if the transformer is properly installed
Display reads “Off,
”
The rain sensor is interrupting irrigation
or the sensor jumper has been removed
Slide the rain sensor bypass switch to the BYPASS position
to bypass the rain sensor circuit, or reinstall
the jumper
Rain sensor will not shut off the system
• Defective rain sensor
• Jumper was not removed when sensor
was installed
• Stations have been programmed to
override the sensor
• Verify operation of rain sensor and proper wiring
• Remove jumper from the sensor terminals
• Reprogram the sensor override to enable the sensor
(see page 11)
Frozen display, or showing incorrect
information
Power surge
Reset the controller per page 24 “Clearing Controller
Memory/Resetting the Controller”
Display shows “ERR” with a number
(1 to 8)
Short in valve wiring circuit, or faulty
solenoid on the station number
indicated
Check wire circuit or solenoid for the valve number
indicated. Repair short or replace solenoid. Press any
button to clear the “ERR” from the display
Display shows “P ERR”
• Faulty pump relay or master
valve wiring
• Incompatible or defective relay or
solenoid
• Under sized wire to the pump relay or
master valve
• Check wiring to relay or master valve solenoid. Press
any button to clear the “P ERR” from the display
• Check electrical specification for the pump relay.
Do not exceed controller's electrical rating. Replace
if defective
• Replace wire with larger gauge wire