To Activate the Controller from the System
Off Mode
1. Press the mode button once. The display
will wake up in the System Off mode.
2. Press the mode button again and “Off”
will disappear from the display. The display
will show the current time. Your controller
is now on and will water automatically
based upon the current program.
Programmable Rain Off
This feature permits the user to stop all
programmed waterings for a designated
period from 1 to 7 days. At the end of the
programmable rain off period, the controller
will resume normal automatic operation.
1. Press the button until the System Off
icon is displayed. Wait 4 seconds and “Off”
will appear on the display.
2. Press the button and a 1 will be
displayed. The 1 will be blinking at this
point.
3. Press the button as many times as
needed to set the number of days off
desired (up to 7). The SVC will wait the
number of days selected and then reactivate
automatic watering.
Manual Watering
The SVC-400 features a simple one touch
manual start. One or more stations can be
programmed to run manually at the same time.
To Activate a Manual Watering:
1. Press the button once to display the
current time of day.
2. Press and hold the button for two
seconds to display the Manual Watering
icon. The station number will also be
displayed
3. Use the or button to adjust the
manual water run time from 1 minute to
4 hours.
4. Release the buttons and the controller will
count down 10 seconds before activating
the manual cycle.
PROGRAMMING THE SVC-400
(continued)
5. The flashing sprinkler icon will appear on
the display when watering is occurring.
6. To activate another station, use the
button to select the station you would like
to manually water, repeat steps 3 and 4.
Note: While manual watering is occurring the
display will briefly display the station number
and the remaining watering time for each station
that is operating. The manual water run time can
be increased or decreased for any time that the
station is displayed.
To Suspend Manual Watering to All
Stations Operating:
1. Press the button until the System
Off icon is displayed. Wait 4 seconds and
“OFF” will appear on the display. All
stations will turn off.
2. Press the button again and the current
time and day will be displayed. The SVC
will now water based upon the current
program.
To Suspend Manual Watering to Individual
Stations Operating:
1. Press the button and the display will
show each of the stations operating
manually.
2. When the station number appears for the
station that you would like to suspend
manual watering, press the button once.
The time remaining displayed will change
to “Off” and the station will turn off.
3. Repeat steps 1 and 2 to suspend watering
for additional stations.
The battery life status icon is a quick way
to determine the remaining life of the installed
battery without having to remove the battery
from the controller. A battery life status icon
will appear along with the time and day on the
display. A fully charged battery will show all
three segment of the battery dark . As the
battery is expended, the segments will appear
as outlines .