60
Turning Off the System ....................................
Press
To display:
• Turns off automatic operation
for both programs, A and B.
• Press RAIN OFF again, or END/CANCEL, to restart operation.
• In Rain Off mode, you can still water manually (press ONE STATION or ALL
STATIONS). System will remain off after manual watering is complete.
• You can also press RAIN OFF to stop manual watering (any
remaining time is lost).
RAIN
Automatic Test Feature .....................................
The PSC-Z test feature allows you to quickly test the display and
station outputs.
• Press the NEXT, LAST, and RAIN OFF buttons at the same time. This
will light the entire display for a quick visual test.
• Then press the ALL STATIONS button to automatically turn each
station on for 3 seconds. Use a multimeter or solenoid to test each
station's output.
• Press the END/CANCEL button at any time during testing to stop the test.
Short Detection .................................................
The PSC-Z is designed with electronic short detection. If a valve
wire is shorted, the PSC-Z will detect the short then continue
watering all other stations. When automatic watering is complete,
the display will show the problem:
• To return to the normal
Time and Day display,
press END/CANCEL.
• To program the controller,
press the buttons you would normally use for programming. The
PSC-Z will again display the error message when the next
automatic watering program is complete.
STATION
Connecting a Rain Sensor .................................
A rain sensor can be connected to the PSC-Z to turn the
controller off when an appropriate amount of rain is measured.
The controller display then appears as shown:
• The sensor connects directly
to the controller. When the
sensor is activated, you can
easily override the sensor
and water manually simply
by pressing ONE STATION or ALL STATIONS.
SENSOR