![Hunter Pro-C Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/hunter/pro-c/pro-c_product-information_2184770009.webp)
7
Pro-C Controller
Heavy-Duty Cabinet…
Built to overcome the elements -
for a long time
The Pro-C is built using a robust heavy-
duty plastic UL listed and NEMA 3R rated
cabinet, which is not subject to UV degra-
dation or color changes. For faster installa-
tion, the cabinet door hinge pin is remov-
able when the door is unlocked and open.
In addition, the cabinet uses the same pro-
fessional key lock on the outdoor model
as the Hunter ICC commercial controller.
The Pro-C cabinet is also designed with
a 3⁄4"-11⁄2" knockout option on the back of
the cabinet, and a 11⁄2" opening for
low voltage and
a 1⁄2" opening for
high voltage in
the bottom of
the cabinet to
accommodate
the wiring needs
of any job.
Programmable 0-7 Day Rain Delay…
No need to return to the controller
to turn it back on
The Pro-C allows you to turn off the con-
troller for a predetermined period of time
(1-7 days) during rainy weather. All pro-
grams are affected, as this delay is global.
After the specified period has elapsed, the
controller will return to automatic mode
and water as scheduled. This delay feature
is very convenient because when the con-
troller is turned off for an event such as
rain or a social activity, the operator will
not have to make a trip to the site to reacti-
vate the controller. In residential systems,
when the operator uses the watering delay
feature there’s no need to worry about
remembering that the controller has been
turned off.
Note: If the controller is programmed
with a 3-day or higher interval-watering
schedule in a program, the controller will
operate at the next watering start time,
regardless of the interval period, effec-
tively resetting the start of the interval
period.
Programmable Delay Between Stations…
Slow closing valves and well recovery will
never be an issue
A programmable delay between stations
solves the problem of slow closing valves
because of a hydraulic overload condition.
The delay also solves the problem of a
system operating off of a slow filling
well, allowing the well to recover between
zones. The Pro-C’s programming will
allow it to fit into any situation where a
delay is necessary, as the delay is program-
mable up to four hours. Delays from 0 to
60 seconds are allocated in 5-second incre-
ments and then up to 4 hours in 1-minute
increments. Note: If the MV circuit is pro-
grammed to operate on the zone, it will
stay hot for the first minute of any pro-
grammed delay.
Содержание Pro-C
Страница 35: ......