Hunter Pro-C Скачать руководство пользователя страница 25

23

Pro-C Controller

PROBLEM                                                  CAUSES                                                   SOLUTIONS

There is no display.

                                 Check AC power wiring.                          Correct any errors.

The display reads "ERR".

                         Electrical noise is entering the                 Check the SmartPort

®

 wiring 

                                                                  system.                                                    harness. If the wires were extended 

                                                                                                                                  then they will need to be replaced 

                                                                                                                                  with shielded cable. Contact your 

                                                                                                                                  local distributor for information on 

                                                                                                                                  shielded cable.

The display reads "P ERR".

                      There is a ground fault in the wire           Check the master valve or pump 

                                                                   to the pump start or master valve.          start wire for continuity. Replace or 

                                                                                                                                  repair the broken wire. Check that

                                                                                                                                  all wire connections are good and 

                                                                                                                                  water tight.

The display reads a station number

        There has been a ground fault with         Check the station wire for continuity.

and ERR, such as "2 ERR".

                       the wire leading to that station.              Replace or repair broken wire.

                                                                                                                                  Check that all wire connections are 

                                                                                                                                  good and water tight.

The display reads "NO AC".

                     There is no AC power present.                Check to see if the transformer is

                                                                                                                                  properly installed.

                                                                  

The display reads "SENSOR OFF".

          The rain sensor is interrupting                Slide the Rain Sensor switch on 

                                                                  irrigation or not installed.                        front panel to the 

BYPASS

 position 

                                                                                                                                  to bypass rain sensor circuit.

Rain sensor will not shut off system.

                                                                      Make sure sensor is micro-switch 

                                                                                                                                  type such as Mini-Clik

®

. Rain Bird

®

 

                                                                                                                                  Rain Check

TM

 is not this type 

                                                                                                                                  and will not work. Check that 

                                                                                                                                  the the jumper has been removed 

                                                                                                                                  from the SEN terminals.

The controller recognizes 12 stations

                                                                     Make sure AC power is connected. 

all the time.

                                                                                                             Reset controller using method 

                                                                                                                                  described on page 24.

The controller does not respond to

          Controller does not recognize                  Turn off the power to the controller 

all stations. Example, the controller 

      modules.

                                                 

and remove the battery. Check all 

has 12 stations but the display will

                                                                         module connections to the    

only go to 6 stations.

                                                                                               controller. Power the controller 

                                                                                                                                  back up. The microprocessor  

                                                                                                                                  will recognize all modules.

The controller is only recognizing

                                                                           Be sure the dial is in correct 

three stations.

                                                                                                          position. Total number of stations 

                                                                                                                                  can be easily checked by placing

                                                                                                                                  dial in 

SET STATION RUN TIMES

 

                                                                                                                                  position and pressing the back 

TROUBLESHOOTING GUIDE

Содержание Pro-C

Страница 1: ... P R O D U C T I N F O R M A T I O N Pro C Controller A Complete Family of Full Featured Residential and Light Commercial Controllers P R O C C O N T R O L L E R ...

Страница 2: ...Product Explanation 12 Installation 13 Programming 17 Troubleshooting Guide 23 SRR Remote Control Product Overview 24 Product Features and Benefits 24 Installation and Programming 26 Technical Information 30 SRP Programmer Product Overview 31 Product Features and Benefits 31 Technical Information 32 TABLE OF CONTENTS ...

Страница 3: ...12 stations simply by adding plug in modules So there s no need to bring along a variety of different sized controllers to see which one is best for the job With its ability to customize to the particular size you need the Pro C will always be the right choice Being a mod ular system the new Pro C also makes inventory a breeze for contractors there are only three different units to stock indoor ca...

Страница 4: ...ty of all residential and light commercial jobs No longer does the installer have to spend extra money on a controller with extra zones that aren t necessary Easy Inventory Management Now only one controller need be stocked for all projects With its modularity the Pro C can be called out as a 3 6 9 or 12 sta tion controller on most irrigation designs making it the only controller necessary to keep...

Страница 5: ...e to water right on schedule The controller will also recharge its circuits to allow another 4 weeks of time keeping Self Diagnostic Electronic Short Circuit Protection No fuses to worry about only faulty sta tions stop watering The Pro C automatically skips shorted stations allowing the rest of the system to operate as normal The self diagnostic electronic short circuit protection system is very ...

Страница 6: ...fferent watering requirements are met with independent programming The Pro C allows for many different irri gation applications using three completely independent programs This is ideal for various types of plants that have separate watering day requirements Each program has the ability to water up to four start times per day The user has complete flex ibility with watering schedules for new seed ...

Страница 7: ... s grounding circuit The Pro C uses these MOV s to protect the controller from minor power surges coming in through the primary 110 230VAC imput side and also the secondary output side 24VAC Note For proper results the ground cir cuit must mea sure 10 ohms or less Global Water Budget Seasonal Adjustment Changing run times could not be easier from 10 to 150 The water budget seasonal adjustment set ...

Страница 8: ...duled to water every third day but Saturdays have been designated as a mow day so no watering can occur Under the Event Day Off selec tion Saturdays can be turned off Sports fields community centers schools and parks will find this feature satisfies their requirements in this regard One Touch Manual Start and Rapid Advance Simple operation for a quick check of zones The One Touch Start and Rapid M...

Страница 9: ...se when the con troller is turned off for an event such as rain or a social activity the operator will not have to make a trip to the site to reacti vate the controller In residential systems when the operator uses the watering delay feature there s no need to worry about remembering that the controller has been turned off Note If the controller is programmed with a 3 day or higher interval wateri...

Страница 10: ... and efficient Primary Voltage Source Choices Indoors or outdoors operates off a variety of power sources Pro C models can be supplied with a 110 VAC 60 Hz transformer for domestic use or a 230 VAC 50 Hz transformer for inter national use This versatile transformer selection enables users to install the Pro C anywhere in the world AM PM or 24 Hour Clock Settings Choose your favorite method of time...

Страница 11: ...r PC using SRP software version 2 0 or greater Download your program into the Hunter SRP Programmer tool Take the SRP tool to the controller attach it to the SmartPort connector fur nished with controller and upload the pro gram into the controller It takes less than a minute The SRP Programmer will accept two independent programs for two differ ent applications Operate Three 7 2 VA Solenoids Simu...

Страница 12: ...h the Hunter Irrigation Management and Monitoring System IMMS The IMMS allows the user to program controller functions that would typically be handled directly at each con troller Scheduling days to water run times start times and more can be done from a single computer at a desk miles away from the installation A key function of the IMMS is its ability to monitor changing conditions with the aid ...

Страница 13: ...Seasonal Adjustment With Visible In Display Thermometer Weather Sensor Displays When Sensor is Active Rain Sensor Override Bypass on Front Panel Programmable Event Day Off for All Day Schedules odd even odd even odd even odd even only only only only One Touch Manual Start Rapid Advance Remote Control Ready From Factory Programmable 0 7 Day Rain Delay Programmable Delay Between Stations Pump Start ...

Страница 14: ...gram for repeat watering needs Removable front panel for field or desktop programming Panel inter changeable between indoor and out door units Up to six hours run time on all stations Automated chronological ordering of start times start time stacking 365 day calendar with leap year intel ligence Programmable event day off allows specific day s to be designated as always off Rain Sensor bypass swi...

Страница 15: ...duit through the 1 2 13mm conduit opening on the left side of the bottom of the cabinet Connect the wires to the trans former wires located inside the junction box International units are supplied with a built in terminal strip Always use a UL listed conduit 1 2 13mm male adapter when installing the AC wiring Insert the adapter male threads first into the 1 2 hole at the bottom of the controller u...

Страница 16: ...re of the valve Attach a separate control wire to the remaining solenoid wire 2 Route the wires into the controller via the field wire conduit 3 Connect either wire from Master Valve to the P MV terminal Connect remaining wire to the C Common terminal Connecting a Pump Start Relay The controller should be mounted at least 15 feet 4 5 m away from both the pump start relay and the pump When a pump i...

Страница 17: ... wiring harness allowing for fast and easy use of Hunter remote controls The remote makes it possible for contractors and end users alike to operate a system without having to walk back and forth to the controller To utilize the SRR or ICR Remote Control System you must install the SmartPort outlet 1 Install a 1 2 female threaded Tee in the field wiring conduit approximately 12 below the Pro C 2 F...

Страница 18: ... an SRR or ICR Remote Control For more information please refer to the SRP manual or contact your local Hunter distributor for information on ordering the SRP Power Failures Due to the possibility of power failures the controller has non volatile memory to preserve the clock calendar and program indefinitely There is no default program so there will be no surprise watering NOTE Any extension of th...

Страница 19: ...osition 2 The current year will be flashing in the display Use the and but tons to change the year After setting the correct year push the button to proceed to setting the month 3 The month and day will be in the dis play The month will be flashing Use the and buttons to change the month Press the button to pro ceed to setting the day 4 The day will be flashing Use the and buttons to change the da...

Страница 20: ...rs 7 You can move between programs while staying on the same station However it is recommended that one program is completed before going on to the next program Jumping between programs can be confusing and may result in program errors Setting Days to Water 1 Turn the dial to the SET DAYS TO WATER position 2 The display will show the last program selected A B or C the station number selected and t...

Страница 21: ...til the next watering After programming set dial to RUN to enable automatic execution of all selected programs and start times Selecting Odd or Even Days to Water This feature uses a numbered day of the month for watering instead of specific days of the week odd days 1st 3rd 5th etc even days 2nd 4th 6th etc 1 Using the instructions for Interval Watering set the interval to one 2 Press the button ...

Страница 22: ... time for the station to water if different from the run time displayed 5 Use the button to move to the next station 6 Repeat steps 3 and 4 to customize each station if desired 7 Press the button until desired start ing station is displayed 8 Return the dial to RUN custom pro gram will water the entire program beginning with the station number last left in the display then controller will return t...

Страница 23: ... of run time from 1 to 15 minutes 3 After a 2 second pause the test pro gram will run each station for the set run time This feature is great for a quick system check or to activate valves during winter ization Advanced Features There are three advanced features avail able to customize the Pro C to more com plex watering requirements One of these features is hidden to make accidentally programming...

Страница 24: ...perat ing near maximum flow or have slow well recovery 1 Start with the dial in the RUN position 2 Press and hold the button down while turning the dial to the SET STA TION RUN TIMES position 3 Release the button At this point the display will show a delay time for all stations in seconds which will be blinking The DELAY icon shall also be lit at this time 4 Press the and buttons to increase or de...

Страница 25: ...operly installed The display reads SENSOR OFF The rain sensor is interrupting Slide the Rain Sensor switch on irrigation or not installed front panel to the BYPASS position to bypass rain sensor circuit Rain sensor will not shut off system Make sure sensor is micro switch type such as Mini Clik Rain Bird Rain CheckTM is not this type and will not work Check that the the jumper has been removed fro...

Страница 26: ...vailable One Transmitter One Receiver Does the Job Portable and reusable at every location With the SRR a contractor can visit one site attach the receiver to the SmartPort wire harness at the controller complete the irrigation operations remove the receiver and travel on to the next job Or the receiver can be left permanently mounted if desired to permit opera tion by the homeowner or building ma...

Страница 27: ...unctions that may be required The default setting is 10 minutes User Programmable Address Added user security Both the SRR transmitter and receiver have an address that they use when communicating with each other If the addresses do not match the receiver will ignore the transmission The SRR comes from the factory with both addresses set at 0 The transmitter address may be changed to any setting f...

Страница 28: ... from the har ness to the terminal block of the con troller as shown in Figure 2 Extending the Wiring Harness Any extension of the wiring on the harness may result in an error message in the controller display and possible malfunction of the remote unit due to radio interference In some situations lengthening of the harness may work fine in others it may not work at all it is site specific In eith...

Страница 29: ...ons until the word RUN TIME along with the current Run Time is displayed The display will be blinking at this point 3 While the display is blinking and showing the current Run Time Press the ON button The word ADDRESS will now illuminate and the current address will be blinking Note that if more than 5 seconds go by without a button being pressed the Transmitter will revert back to display ing the...

Страница 30: ...wered controller and wait for 2 beeps indi cating that the Receiver is ready 2 If your Transmitter is not on no dis play press any button for at least 1 second and release The Transmitter will first illuminate the entire display then display the active station 3 Use the or buttons to display the station or program you would like to start 4 Momentarily press the ON button to start the station or pr...

Страница 31: ...s of metal such as power meters water pipes and aluminum siding 2 Do not install the outlet of the wiring harness in a basement or underground location The higher the better 3 For maximum range in all directions from the Receiver the Receiver antenna should be pointed straight up vertically If the Receiver is mounted with its antenna oriented horizontally reception will be very good if the Transmi...

Страница 32: ...wiring harness Additional SRR owner s manuals can be ordered by Hunter part number LIT 217 EXAMPLE SRR KIT P R O D U C T E X P L A N A T I O N MODEL SRR FEATURES KIT Transmitter Receiver Wiring Harness and Owners Manual SCWH 25 Shielded Cable Connection Kit TR Transmitter R Receiver Models SRR KIT Transmitter receiver wiring harness and owners manual SRR SCWH Connection Kit with 25 shielded cable ...

Страница 33: ...ible with the ICC and SRC Controllers PRODUCT OVERVIEW SRP Programmer Windows Compatible Software Works with most computer systems The SRP version 2 0 software is compat ible with Windows 3 1 Windows 95 and Windows 98 and it is easy to under stand and simple to use The program leads the user through the programming process Compact Design Provides Simple and Reliable Operation Download a custom des...

Страница 34: ...oller wiring harness Model SRP KIT Simple Reliable Programmer Dimensions Width 21 2 6 cm Height 23 4 7 cm Depth 1 2 5 cm Operating Specifications Download time less than one minute Upload time less than one minute Number of schedules in a single hand held unit 2 RS232 1200 Baud communication Non volatile memory programs stay in memory until changed by the user No battery required Handheld unit can...

Страница 35: ......

Страница 36: ...tries Incorporated The Irrigation Innovators 2002 Hunter Industries Incorporated 1940 Diamond Street San Marcos California 92069 TEL 1 760 744 5240 FAX 1 760 744 7461 www HunterIndustries com P N 700757 LIT 325 3 02 ...

Отзывы: