2

 DISCONNECT 

ELECTRIC 

POWER SUPPLY 

AND LOCK OUT 

SERVICE PANEL 

BEFORE 

SERVICING UNIT

  W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.

  For general ventilating use only. Do not use for ventilat-

ing hazardous or explosive materials.

2.  

To avoid motor bearing damage and noisy/unbalanced 
impellers, keep drywall spray, construction dust, etc. 
off power unit.

3.

  DO NOT install this product in a wall. This product is 

designed for installation in ceilings up to a 12/12 pitch 
(45 degrees). Ductwork must point upward.

4.

  Please read specification label on product for further 

information and requirements.

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE:

 Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel 

wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY:

 Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor 

plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a 
screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
 

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 
noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

 

C a U T i O n

  W a r n i n g

1.

  Use this unit only in a manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the phone 
number or address listed in the warranty.

2.

  Before installing, servicing, or cleaning the unit,  

disconnect the power by turning off the circuit breakers to 
the outlet box and associated wall switch location. If you 
cannot lock the circuit breakers in the off position, securely 
attach a prominent warning device, such as a tag, to the 
service panel.

 

3.

  Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.

  Sufficient air is needed for proper combustion and exhaust-

ing of gasses through the flue (chimney) of fuel burning 
equipment to prevent backdrafting. Follow the heating  
equipment manufacturer’s guideline and safety standards, 

   such as those published by the National Fire Prevention 

Association (NFPA), and the American Society for Heating, 
Refrigeration and Air-Conditioning Engineers (ASHRAE), and 
the local code authorities.

  5.

  When cutting or drilling into wall(s) or ceiling, do not  

damage electrical wiring or other hidden utilities.

  6.

  Ducted fans must always be vented to the outdoors. Keep 

ducting as short and as straight as possible.

  7.

  Acceptable for use over a bathtub or shower when  

connected to a GFCI protected branch circuit.

  8.

 Install fan at least 5 feet (1.52 m) above the floor.

  9.

  Never place a switch where it can be reached from a tub  

or shower.

10.

 This unit must be grounded.

 

41947-01   3/29/2006

 

41947-01   3/29/2006 

05-HF-016-EngS_3.29.06.indd   2

3/29/06   6:40:43 PM

Содержание Orleans 82006

Страница 1: ...l l a t i o n G u i d e 82006 Orleans Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 41947 01 3 29 2006 ENGLISH See page 2 Espa ol Vea la p gina 15 05 HF 016 EngS_3 29 06 indd 1 3 29 06 6...

Страница 2: ...e motor You should replace the impeller at the same time C A U T I O N W a r n i n g 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer at the...

Страница 3: ...0 01 444 Extra Screws x2 D K 74933 01 000 L 75882 01 000 3 8 Cable Connector 3 1 Turn off the power source Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installation Check...

Страница 4: ...emove the pre loaded screw tip covers Remove the wiring cover screw 6 Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover Remove packing material 41947...

Страница 5: ...th mark at the bottom edge of the joist based on the thickness of your sheetrock New Construction 5 10 B C A11 E 5 8 1 2 5 8 1 2 A12 Screw pre loaded screws into joist or framing 41947 01 3 29 2006 Ch...

Страница 6: ...Route wires through the strain relief Connect wires as shown 0 0 A16 Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased 6 A15 E F G...

Страница 7: ...0 0 0 0 A17 Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing 0 0 0 0 0 0 0 0 H A18 ON OFF A21 Test the motor...

Страница 8: ...arge enough to accommodate the new motor hous ing 7 1 4 x 7 3 4 Move the housing into position above the ceiling Attach existing ducting to duct connector Tape joints If ducting does not fit securely...

Страница 9: ...own Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Connect wiring harness DO NOT ALLOW THE MOTOR TO HANG F...

Страница 10: ...ESS ON OFF B22 B23 C1 Go to step on page 10 to attach grille B21 Test the motor If the motor does not run check the plug connection Turn on the power source Attaching the Grille Remove the thumbscrews...

Страница 11: ...C7 O Screw finial into position C5 L C6 N Attach thumbscrews WARNING To reduce the risk of electrical shock all 3 thumbscrews MUST be properly installed M C4 Align posts 1 2 and 3 stamped into motor h...

Страница 12: ...ght does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure they are secure Check the wiring to make sure it...

Страница 13: ...OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BAT...

Страница 14: ...2500 Frisco Avenue Memphis Tennessee 38114 Printed in China 41947 01 3 29 2006 14 2006 Hunter Fan Company 05 HF 016 EngS_3 29 06 indd 14 3 29 06 6 41 10 PM...

Страница 15: ...DESDE G u a d e i n s t a l a c i n Ventilador para ba o Orleans 82006 con luz LEA y CONSERVE ESTAS INSTRUCCIONES 41947 02 3 29 2006 Espa ol 15 05 HF 016 Sp_3 29 06 indd 15 3 29 06 6 41 58 PM...

Страница 16: ...engrasado Si los rodamientos del motor hacen ruidos excesivos o inusuales reemplace el motor con el motor de servicio exacto Debe reemplazar el impulsor al mismo tiempo PRECAUCI N ADVERTENCIA 1 Utili...

Страница 17: ...ector de cable de 3 8 Tornillos adicionales 17 1 Apague la fuente de alimentaci n Herramientas necesarias no suministradas Tiempo estimado de ensamblaje entre 30 y 60 minutos Antes de la instalaci n 2...

Страница 18: ...o de la cubierta del cableado 6 Retire las puntas de tornillo precargadas hasta que est n a nivel con el lado del alojamiento Retire la cubierta del cableado Retire el material de embalaje Retire el m...

Страница 19: ...ueva 19 10 B C A11 E 5 8 1 2 5 8 1 2 A12 Instale los tornillos precargados en la viga o el marco Ubique la correcta marca de profundidad en el borde infe rior de la viga seg n el espesor de su plancha...

Страница 20: ...s del manguito de alivio de tension Conecte los alambres como se muestra 0 0 A16 Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede...

Страница 21: ...a instalar el motor introduciendo las pesta as y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el alojamiento 0 0 0 0 0 0 0 0 H A18 ENCENDIDO APAGADO A21 Prueb...

Страница 22: ...e grande para acomodar el alojamiento del motor nuevo 7 1 4 x 7 3 4 Mueva el alojamiento a su posici n encima del techo Conecte el ducto existente con el conector de ducto Aplique cinta a las uniones...

Страница 23: ...omo se muestra Vuelva a instalar el motor introduciendo las pesta as y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el alojamiento Conecte el mazo de cables NO...

Страница 24: ...o funciona verifique la conexi n del enchufe Encienda la fuente de alimentaci n Fijaci n de la rejilla Retire los tornillos de mano Conecte el mazo de cables NO PERMITA QUE EL ARTEFACTO DE ILUMINACI N...

Страница 25: ...mental C5 L C6 N Instale los tornillos de mano ADVERTENCIA Para reducir el riesgo de descarga el ctrica los 3 tornillos de mano DEBEN instalarse apropiadamente M C4 Alinee los postes 1 2 y 3 estampado...

Страница 26: ...l diagrama de cableado Problema La luz no funciona Soluci n Reemplace la bombilla con una nueva Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico Verifiqu...

Страница 27: ...E AIRE PARA BA O ESTA GARANT A SUSTITUYEATODAS LAS OTRAS GARANT AS EXPRESAS LA DURACI N DETODA GARANT A IMPL CITA INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GARANT A IMPL CITA DE COMERCIABILIDAD O IDON...

Страница 28: ...2500 Frisco Avenue Memphis Tennessee 38114 Impreso en China 41947 02 3 29 2006 2006 Hunter Fan Company 05 HF 016 Sp_3 29 06 indd 28 3 29 06 6 42 26 PM...

Отзывы: