Hunter’s Wireless Rain-Clik™ and the Flow-Clik IMMS require 24VAC
power over their yellow wires.
POWERED SENSORS ..............................................................................................................
1. Route the receiver cable through the low-voltage conduit.
2. Strip and connect the 2 yellow power wires from the sensor receiver
to the power terminals in the interface.
3. This will double the yellow wires in each terminal, one each from the
interface transformer, and one each from the sensor power.
4. Route and connect the white sensor signal wire to the desired sensor
input, and the blue wire to the Sensor Common. The orange wire is
not used in an IMMS connection.
WIRELESS RAIN-CLIK™ .........................................................................................................