Hunter EC Скачать руководство пользователя страница 7

5. 

Indoor model:

 route transformer cable through the left side of the 

controller and connect the wires to the two screws marked AC. 

WATER DAYS

SEASONAL ADJUSTMENT

WATER DAYS

SEASONAL ADJUSTMENT

Valve Common Wire

Connect the Two

Transformer Wires to

the Two AC Terminals

Valve 1

Valve 2

Valve 3

Valve 4

Valve

Wires

6

5

4

3

2

1

P

C

SEN

RST

AC

9 V Battery

Wire Clip

WATER DAYS

SEASONAL ADJUSTMENT

WATER DAYS

SEASONAL ADJUSTMENT

6

5

4

3

2

1

P

C

SEN

RST

AC

9 V Battery

Battery Compartment

Valve Common Wire

Valve 1

Valve 2

Valve 3

Valve 4

Valve

Wires

Master Valve

Master Valve Wire

WATER DAYS

SEASONAL ADJUSTMENT

WATER DAYS

SEASONAL ADJUSTMENT

6

5

4

3

2

1

P

C

SEN

RST

AC

9 V Battery

ENG

CONNECTING THE BATTERY

Connect a 9-volt alkaline battery (not 

included) to the battery wire clip located in 

the lower left-hand side of the controller. 

The battery will allow you to program the 

controller without AC power. However, the 

battery will not be able to activate any of 

the station valves. AC power must resume 

before watering will continue.

CONNECTING A MASTER VALVE

NOTE: Complete this section only if you have a master valve 

installed. A master valve is a “normally closed” valve 

installed at the supply point of the main line that opens only 

when the controller initiates a watering program.

1.  At the Master Valve, attach the common wire to either solenoid 

wire of the valve. Attach a separate control wire to the remaining 

solenoid wire.

2.  The common wire will still go to the screw slot marked C. The ad-

ditional wire coming from the master valve will go in the screw slot 

marked P.

 

Outdoor model:

 transformer wires are already connected to the 

AC slots so all that is required is to connect primary power to the 

junction box from a power source.

E – High Voltage Wiring Compartment (Outdoor Model only)

NOTE: Outdoor model is water and weather resistant. 

Connecting the outdoor EC to the primary power should 

only be done by a licensed electrician following all  

local codes. Improper installation could result in shock 

or fire hazard.

Route AC power cable and conduit through the ½" (13 mm) conduit 

opening on the the left side of the bottom of the cabinet and connect 

one wire to each of the two wires 

inside the junction box

. Do not 

connect high voltage wires to the AC terminals inside the controller. 

Wire nuts are provided to make these wire connections. Note: For -E 

models, connect the wires to the AC terminal strip located inside the 

junction box.

Do not plug transformer into power source until the con-

troller is mounted and all valves have been connected.

4

Содержание EC

Страница 1: ...er s Manual and Programming Instructions Programador de Riego Residencial Manual de Operación e Instrucciones de Programación Programmateurs EC pour Sites Résidentiels Manuel de l utilisateur et instructions de programmation du programmateur Programmatori EC Manuale dell utente ed istruzioni per la programmazione Bewässerungssteuerung Bedienungs und Montageanleitung ENG ESP FR IT DEU ...

Страница 2: ......

Страница 3: ...er Continued Setting Station Run Times Length of Watering for Each Area 8 Setting Days To Water 8 Selecting Specific Days of the Week to Water 8 Selecting Interval Watering 8 Automatic 8 System Off 8 Programmable Rain Off 9 Bypass Weather Sensor 9 Seasonal Adjustment 9 1 Manually Run a Single Station 9 ALL Manually Run All Stations 9 10 One Touch Manual Start and Advance 10 Hidden Features 10 Prog...

Страница 4: ... ALL STATIONS ALL AUTOMATIC SYSTEM OFF RUN TIMES EC START TIMES CURRENT TIME DAY WATER DAYS SEASONAL ADJUSTMENT MANUAL ONE STATION 1 MANUAL ALL STATIONS ALL 6 5 4 3 2 1 P C SEN RST AC 14 13 16 15 B E A C Outdoor Model Internal Transformer Included Indoor Model EC COMPONENTS Note Plug may look different from Illustration 1 ...

Страница 5: ...tery 15 Terminal Strip Area Use to attach transformer and valve wires from their source to the controller 16 Reset Button Use to reset the controller 17 Conduit Cover Covers the field wires as they exit the conduit into the bottom of the controller C Control Buttons Button Increases the selected flashing display Button Decreases the selected flashing display Button Advances the selected flashing d...

Страница 6: ...s to the bottom of the controller Make sure that there is a sufficient length of conduit so it enters the conduit cover There are two small notches on the left side of the cover to route the 24VAC wires from the external transformer or wires from the sensor and P MV if applicable 4 Secure the conduit cover to the wall with the screws and anchors provided 5 Replace the lower access panel on the EC ...

Страница 7: ...nstalled at the supply point of the main line that opens only when the controller initiates a watering program 1 At the Master Valve attach the common wire to either solenoid wire of the valve Attach a separate control wire to the remaining solenoid wire 2 The common wire will still go to the screw slot marked C The ad ditional wire coming from the master valve will go in the screw slot marked P O...

Страница 8: ... wire from the pump relay to the P screw slot Relay holding current draw must not exceed 28 amps Do not connect controller directly to pump damage to controller can result CONNECTING A WEATHER SENSOR A Hunter weather sensor or other type of micro switch weather sensor can be connected to the EC The purpose of this sensor is to stop watering when weather conditions dictate 1 Remove the jumper that ...

Страница 9: ...LOCATION 1 2 3 4 5 6 STATION STATION RUN TIME STATION RUN TIME STATION RUN TIME 1 2 3 4 PROGRAM START TIMES HUNTER EC NOTES DAY OF THE WEEK INTERVAL Choose 1 to 31 days 1 2 3 4 5 7 6 1 2 3 4 5 7 6 1 2 3 4 5 7 6 WATERING SCHEDULE FORM 6 ...

Страница 10: ...s will be flashing Use the or button to change the minutes shown on the display Press the to proceed to select AM PM or 24 hour time 4 The time will be displayed and an arrow will be flashing on AM Press the and but tons to select AM PM or 24 hour Press the to proceed to setting the day of the week 5 The number for day 1 will be flashing Press the and to select the day of the week corresponding to...

Страница 11: ...seconds All active programs are discontinued and watering is stopped To return controller to normal automatic operation simply return dial to AUTOMATIC position PROGRAMMING THE CONTROLLER cont NOTE If a program has all four start times turned off then that program is off All other program details are retained Because there are no start times there will be no watering with that program This is a co...

Страница 12: ...l as the bar graph which always remains on the display Press the or buttons to adjust the percentage of the seasonal ad justment Each bar on the graph represents 10 This feature can adjust the controller from 10 to 150 of the original program To view the new adjusted run times simply turn the rotary dial to the SET STATION RUN TIMES position the displayed run time will be updated accordingly as th...

Страница 13: ... a 2 second pause the program will begin HIDDEN FEATURES Programmable Delay Between Stations This feature allows the user to insert a delay between when one station turns off and the next station turns on 1 Start with the dial in the AUTOMATIC position 2 Press and hold the button down while turning the dial to the SET STATION RUN TIMES position 3 Release the button At this point the display will s...

Страница 14: ...r short or faulty wire connections Replace solenoid Display shows ERR with a number 1 6 Short in valve wiring circuit or a faulty solenoid on the station number indicated Check wire circuit or solenoid for the valve number indicated Repair short or replace solenoid Press any button to clear ERR display Display shows P ERR Faulty pump relay or master valve wiring Incompatible or defective pump rela...

Страница 15: ... 1 minute increments Start Times 4 per day per program for up to 12 daily starts Watering Schedule 7 day calendar or interval 1 to 31 day programming AM PM or 24 hour clock option Start time stacking Simple manual operation including 1 button manual operation Seasonal Adjustment 10 to 150 in 10 increments Electrical Specifications Transformer Input 230 240VAC 50 60Hz International Use Transformer O...

Страница 16: ...ERTIFICATE OF CONFORMITY TO EUROPEAN DIRECTIVES Hunter Industries declares that the irrigation controller Model EC complies with the standards of the European Directives of electromagnetic compatibility 87 336 EEC and low voltage 73 23 EEC __________________________________ Project Engineer 13 ...