SYSTEM OFF

AUTOMATIC

SEASONAL ADJUSTMENT

MANUAL-ONE STATION

1

MANUAL-ALL STATIONS

ALL

Programmable Rain Off

This feature permits the user to stop all pro-

grammed waterings for a designated period from 

1 to 7 days. At the end of the programmable rain 

off period, the controller will resume normal 

automatic operation.
1.  Turn the dial to the 

SYSTEM OFF

 position. 

Wait for 

OFF

 to be displayed.

2.  Press   as many times as needed to set  

the number of days off desired (up to 7).

3.  Turn the dial back to the 

AUTOMATIC

 position at 

which time, 

OFF

a number

 and the 

DAYS

 icon 

all remain on.

The days off remaining will decrease at midnight 

of each day. When it goes to zero, the display will 

show the normal time of day and normal irrigation 

will resume at the next scheduled start time.

Bypass Weather Sensor

If the weather sensor is interrupting irrigation, you can bypass it by 

using the manual watering options described below. The dial positions 

MANUAL-ONE STATION

 and position 

MANUAL-ALL STATIONS

 as well 

as the One Touch Start and Advance process will successfully bypass 

the rain sensor. 

Seasonal Adjustment 

Seasonal Adjust is used to make global run time changes without 

re-programming the entire controller. To use the seasonal adjustment 

feature: 
1.  Turn the dial to the 

SEASONAL  

ADJUSTMENT

 position.

2.  The display will now show a flashing number followed by a %, as 

well as the bar graph which always remains on the display. Press 

the   or   buttons to adjust the percentage of the seasonal ad-

justment. Each bar on the graph represents 10%. This feature can 

adjust the controller from 10% to 150% of the original program.  

To view the new adjusted run times, simply turn the rotary dial to 

the 

SET STATION RUN TIMES

 position, the displayed run time will be 

updated accordingly as the seasonal adjustment is made.

NOTE: The controller should always be initially pro-

grammed in the 100% position.

Manually Run a Single Station 

1

1.  Turn dial to the 

MANUAL-ONE STATION

 position.

2.  Station run time will flash in the display. Use the   button to 

move to the desired station. You may use the   or   button to 

select the amount of time for a station to water.

3.  Turn the dial clockwise to the 

AUTOMATIC

 position to run the sta-

tion (only the designated station will water, then the controller will 

return to automatic mode with no change 

in the previously set program). Also see 

One Touch Manual Start and Advance

 on 

page 10.

Manually Run All Stations 

ALL

1.  Turn dial to 

MANUAL-ALL STATIONS

.

2.  Select program A, B, or C by pressing the   button.
3.  Press the   button until desired starting station is displayed.
4.  Station run time will flash in the display. Use the   or   button 

to select the amount of run time for the station to water if different 

from the run time displayed.

5.  Use the   button to move to the next station.
6.  Repeat steps 3 and 4 to customize 

each station if desired.

7.  Press the   button until you reach the 

station that you would like watering to begin.

9

Содержание EC

Страница 1: ...er s Manual and Programming Instructions Programador de Riego Residencial Manual de Operación e Instrucciones de Programación Programmateurs EC pour Sites Résidentiels Manuel de l utilisateur et instructions de programmation du programmateur Programmatori EC Manuale dell utente ed istruzioni per la programmazione Bewässerungssteuerung Bedienungs und Montageanleitung ENG ESP FR IT DEU ...

Страница 2: ......

Страница 3: ...er Continued Setting Station Run Times Length of Watering for Each Area 8 Setting Days To Water 8 Selecting Specific Days of the Week to Water 8 Selecting Interval Watering 8 Automatic 8 System Off 8 Programmable Rain Off 9 Bypass Weather Sensor 9 Seasonal Adjustment 9 1 Manually Run a Single Station 9 ALL Manually Run All Stations 9 10 One Touch Manual Start and Advance 10 Hidden Features 10 Prog...

Страница 4: ... ALL STATIONS ALL AUTOMATIC SYSTEM OFF RUN TIMES EC START TIMES CURRENT TIME DAY WATER DAYS SEASONAL ADJUSTMENT MANUAL ONE STATION 1 MANUAL ALL STATIONS ALL 6 5 4 3 2 1 P C SEN RST AC 14 13 16 15 B E A C Outdoor Model Internal Transformer Included Indoor Model EC COMPONENTS Note Plug may look different from Illustration 1 ...

Страница 5: ...tery 15 Terminal Strip Area Use to attach transformer and valve wires from their source to the controller 16 Reset Button Use to reset the controller 17 Conduit Cover Covers the field wires as they exit the conduit into the bottom of the controller C Control Buttons Button Increases the selected flashing display Button Decreases the selected flashing display Button Advances the selected flashing d...

Страница 6: ...s to the bottom of the controller Make sure that there is a sufficient length of conduit so it enters the conduit cover There are two small notches on the left side of the cover to route the 24VAC wires from the external transformer or wires from the sensor and P MV if applicable 4 Secure the conduit cover to the wall with the screws and anchors provided 5 Replace the lower access panel on the EC ...

Страница 7: ...nstalled at the supply point of the main line that opens only when the controller initiates a watering program 1 At the Master Valve attach the common wire to either solenoid wire of the valve Attach a separate control wire to the remaining solenoid wire 2 The common wire will still go to the screw slot marked C The ad ditional wire coming from the master valve will go in the screw slot marked P O...

Страница 8: ... wire from the pump relay to the P screw slot Relay holding current draw must not exceed 28 amps Do not connect controller directly to pump damage to controller can result CONNECTING A WEATHER SENSOR A Hunter weather sensor or other type of micro switch weather sensor can be connected to the EC The purpose of this sensor is to stop watering when weather conditions dictate 1 Remove the jumper that ...

Страница 9: ...LOCATION 1 2 3 4 5 6 STATION STATION RUN TIME STATION RUN TIME STATION RUN TIME 1 2 3 4 PROGRAM START TIMES HUNTER EC NOTES DAY OF THE WEEK INTERVAL Choose 1 to 31 days 1 2 3 4 5 7 6 1 2 3 4 5 7 6 1 2 3 4 5 7 6 WATERING SCHEDULE FORM 6 ...

Страница 10: ...s will be flashing Use the or button to change the minutes shown on the display Press the to proceed to select AM PM or 24 hour time 4 The time will be displayed and an arrow will be flashing on AM Press the and but tons to select AM PM or 24 hour Press the to proceed to setting the day of the week 5 The number for day 1 will be flashing Press the and to select the day of the week corresponding to...

Страница 11: ...seconds All active programs are discontinued and watering is stopped To return controller to normal automatic operation simply return dial to AUTOMATIC position PROGRAMMING THE CONTROLLER cont NOTE If a program has all four start times turned off then that program is off All other program details are retained Because there are no start times there will be no watering with that program This is a co...

Страница 12: ...l as the bar graph which always remains on the display Press the or buttons to adjust the percentage of the seasonal ad justment Each bar on the graph represents 10 This feature can adjust the controller from 10 to 150 of the original program To view the new adjusted run times simply turn the rotary dial to the SET STATION RUN TIMES position the displayed run time will be updated accordingly as th...

Страница 13: ... a 2 second pause the program will begin HIDDEN FEATURES Programmable Delay Between Stations This feature allows the user to insert a delay between when one station turns off and the next station turns on 1 Start with the dial in the AUTOMATIC position 2 Press and hold the button down while turning the dial to the SET STATION RUN TIMES position 3 Release the button At this point the display will s...

Страница 14: ...r short or faulty wire connections Replace solenoid Display shows ERR with a number 1 6 Short in valve wiring circuit or a faulty solenoid on the station number indicated Check wire circuit or solenoid for the valve number indicated Repair short or replace solenoid Press any button to clear ERR display Display shows P ERR Faulty pump relay or master valve wiring Incompatible or defective pump rela...

Страница 15: ... 1 minute increments Start Times 4 per day per program for up to 12 daily starts Watering Schedule 7 day calendar or interval 1 to 31 day programming AM PM or 24 hour clock option Start time stacking Simple manual operation including 1 button manual operation Seasonal Adjustment 10 to 150 in 10 increments Electrical Specifications Transformer Input 230 240VAC 50 60Hz International Use Transformer O...

Страница 16: ...ERTIFICATE OF CONFORMITY TO EUROPEAN DIRECTIVES Hunter Industries declares that the irrigation controller Model EC complies with the standards of the European Directives of electromagnetic compatibility 87 336 EEC and low voltage 73 23 EEC __________________________________ Project Engineer 13 ...