Conditional Response
SOS (STATUS OUTPUT STATION)
An SOS is a dedicated station output that is only used with
Conditional Response. The purpose of the SOS is to trigger
an external light or other device when the controller is in an
alarmed state, so that field personnel can be notified of an
alarm without having to open the controller door.
An SOS requires a dedicated station number to operate
(any station number may be used). The station will turn on
whenever the Conditional Response condition is in effect.
The station output may be used to directly power a 24VAC
signal lamp installed in a conduit hole, or used to activate a
relay for other purposes.
SET UP AN SOS STATION
In the Conditional Response screen, use the “Then” soft key to
select a “Start SOS Output” Type.
At Selection, select the unused station you want to designate
as the SOS station.
•
This station must not be included in any irrigation
programs.
•
Only one SOS station should be used per controller.
•
All other SOS responses should be selected to the same
SOS station number.
•
The SOS station output will be wired directly to the
external light or other 24V powered device.
•
In Decoder Controllers, the SOS must be operated by a
decoder station. We recommend programming and placing
a single station ICD-100 in the controller cabinet for
this purpose.
START STATIONS, PROGRAMS, AND BLOCKS
When using Conditional Response to start a Station, Program,
or Block, other options appear below the selection.
MODE
If the Mode is set to
Manual
, the Station, Program, or Block
will run alone, and all other automatic irrigation is stopped
until the response is finished.
If the Mode is set to
Auto
, the response will occur without
halting other scheduled irrigation. If the system is using
Flow Manager, the response may not begin immediately.
The responding stations will be fit into the Flow Target, as
available, by the Flow Manager.
If
Stop if Condition Clears
is checked, the Station, Block, or
Program will only run while the trigger condition is present.
If the condition continues, a Station or Block will run for
the specified run time, and a program will run once for the
duration of the program.
If the box is not checked, the response will continue for the
total Run Time or duration of the program.