Basic Programming and Setup
SENSOR RESPONSE
Located on the Devices menu, Sensor Response sets which
sensors will shut off which programs, in basic operations.
The sensor responses are set up for each program, one
page at a time. If you want the same responses for multiple
programs, set up the responses for the first program, then
click the Copy soft key. You can then change the program
number and click the Paste soft key to duplicate the settings.
There are three standard Clik sensor inputs on the Power
Supply Board. If a Hunter Solar Sync sensor has been
configured, there are also settings for Solar Sync Rain and
Freeze.
Ignore:
This means the program does not respond to the
sensor.
Suspend (recommended):
This means the program suspends
watering when sensor is active (alarmed) but keeps track of
time. If the sensor returns to normal, the suspended program
will resume irrigating where it should be at that time in
the schedule. The program will end when it was originally
scheduled to end.
Pause (use caution):
This means that the program stops
where it is when the sensor is active. If the sensor returns to
normal, the program will resume watering where it left off,
causing the program to end later than originally scheduled.
It is not possible for a program to be set to both Pause and
Suspend for different sensors, because they cannot both be
active at the same time. If you change a response setting for
a sensor, and another sensor for the same program changes
automatically, this is not a bug.
Rain Delay:
In the Sensor Response menu, press the soft key
for Rain Delay. This optional setting will cause watering to stay
off for a set number of days, after the sensor activation is over.
Select the number of days for watering to stay off for each Clik
sensor input.