9.2. Connecting & configuring relay out
9.2.1. Specifications
In order to run relay output of HVR DS1600 series normally, the following conditions are required.
#Output Ch.
4Ch. Rrelay differential outputs
Output type
Dry Contact
Spec.
Connecting type
Connect the trimmed wire to terminal block
24V DC, 1.25A, 30W
DC
125V DC, 0.24A, 30W
125V AC, 0.5A, 62.5VA
Rating
AC
250V AC, 0.25A, 62.5VA
9.2.2. Connecting relay out
Connect R1 ~ R4 with referring to the followings. It shows to connect a warning light. Please refer to
“<Note> Wire Handling”