5.2.25 Slave Reader Setting
Command Code 96
Allows user to change the valid card mode. For key value, please
refer to the table below:
Function Table
Input Value
Key Value
Input Value
Key Value
0
Do not need check password
0
Check Password
+1 Check
Password
1
0 Enable
Anti
0
Disable Anti
+4 Disable
Anti
4
0 T1/T2
Interface
0
+16
Wiegand 26 Interface(8 Digits)
16
+32
Wiegand 26 Interface(10 Digits)
32
Interface
+48
Wiegand 34Interface(10 Digits)
48
Example
:
Slave reader with T2 interface, request check password and enable Anti-password
function.
0+1+4=5, Input 5 and then setting completed.