Safety Precautions 

To ensure the maximum reliability of the HTA-810/820/830/840, please follow the guidelines listed 

below:  

 

DO’s 

z

 

Always read the safety precautions carefully. Keep this user manual for future reference.   

z

 

When product has been damaged during transit, kindly inform your courier.   

z

 

Install the device in a dry, well-ventilated, chemical-free area.     

z

 

Use only the power supply specified for your device and in compliance with IEC 60950.   

Power supply of other electronic devices may look similar, but they may affect your device’s 

performance or damage it. 

z

 

Installation of this product must be done by authorized, qualified technicians. 

z

 

If any of the following situations arises, get the product checked by a service personnel:   

-

 

The power cord or plug is damaged.   

-

 

Liquid has penetrated into the equipment.   

-

 

The equipment has been exposed to moisture.   

-

 

The equipment does not work well or you cannot get it work accordingly to the User 

Manual.  

-

 

The equipment has been dropped and damaged.   

-

 

The equipment has obvious signs of breakage.   

z

 

When replacement parts are required, be sure that the service technician has used 

replacement parts specified by the manufacturer or with same characteristics as original part. 

Unauthorized substitutions may result in fire, electric shock, or other hazards. 

z

 

Use only the metal housing specified / supplied by the manufacturer to ensure compliance 

with EN55024 safety requirement.   

z

 

Unplug this product from wall outlet and refer service to qualified service personnel if the 

product does not operate normally after following the user manual.   

z

 

After turning off the power, kindly wait 3 sec and above before turning the power on to ensure 

that all electric charges are fully discharged.   

z

 

Use only the power cord designated by our dealer to ensure safety and EMC. When used with 

other power supply voltage, the power cable will be damaged. Use the standard power plug 

and cord set of specified country. Consult your product dealer.   

z

 

Kindly use IEC60950/EN60950/UL60950 compliant Uninterrupted Power Supply only.   

Alternative products might damage the device or cause fire and electric shock. 

DON’Ts 

z

 

Do not expose the device to extreme temperature, directly under the sun, humid environment, 

near chemicals or places with high electromagnetic interferences.   

z

 

Installation of this device near flammable materials is extremely prohibited. 

z

 

Do not alter the device for it will 

VOID 

your warranty.   

z

 

Do not place the device in an area with an excessive amount of dirt.    Use only clean, dry cloth 

to clean the controller. 

 

10

Содержание HTA-810

Страница 1: ...Auto Manual Clock in and Clock out for HTA 820 830 840 Daylight Saving Control TCP IP Communication for HTA 830 840 Perfect for wall mount or desktop use Excellent for Payroll Management PoE Power ov...

Страница 2: ...in order to improve reliability design or function The manufacturer will not be held responsible for technical or editorial omissions made herein nor for the incidental or consequential damages result...

Страница 3: ...ecautions 10 Pictorial Introduction 12 Wiring Connections 15 RS 485 Wiring Connection 15 RS 232 Wiring Connection 15 TCP IP RJ 45 Connection for HTA 830 16 TCP IP RJ 45 Connection for HTA 840 16 Alarm...

Страница 4: ...Barcode Cards x 3 Screws x 4 Quick Start Guide x 1 Additional items for HTA 810 820 DC Jack Converter x 1 If adaptor is not included Adaptor x 1 Optional Cable x 1 Additional items for HTA 830 DC Jack...

Страница 5: ...0M HTA 820M HTA 830M HTA 840M Proximity Type HTA 810PE HTA 820PE HTA 830PE HTA 840PE HID Type HTA 810PH HTA 820PH HTA 830PH HTA 840PH Mifare Type HTA 810PM HTA 820PM HTA 830 PM HTA 840 PM To better se...

Страница 6: ...HTA 810 820 HTA 830 840 uses TCP IP communication interface Visual LED for distant display of time card number last 4 digits and for communication mode swiped card indication Preset 16 time schedule f...

Страница 7: ...s Keypad Backlight N A YES YES YES Re swiped card auto examine 0 255 sec 0 255 sec 0 255 sec 0 255 sec Clock in and Clock out N A YES YES YES Daylight Saving Control YES YES YES YES Preset 16 time sch...

Страница 8: ...der Ports ABA Track 2 Wiegand26 x 1 Operating Voltage DC 12V 500mA DC 48V 57V Max 500 mA Power Consumption 3W max 5W 24W max Baud Rate 1200 2400 4800 9600 19200 bps N 8 1 default 9600 10Mbps Comm Inte...

Страница 9: ...Physical Dimensions Front View Side View Back Base 9...

Страница 10: ...th same characteristics as original part Unauthorized substitutions may result in fire electric shock or other hazards z Use only the metal housing specified supplied by the manufacturer to ensure com...

Страница 11: ...k short circuit or it might burn the controller z Do not distort pull nor bend the power cable z Do not switch the power on off within a short period of time z Do not overload wall outlets extension c...

Страница 12: ...840 3 Communication LED Red LED blinks upon receipt of data from PC Green LED blinks upon trasmission of data to PC 4 Swipe Card Indication LED Green LED blinks upon swipe of valid card Red LED blink...

Страница 13: ...Backview With Base HTA 810 820 HTA 810 820 without Base 13...

Страница 14: ...HTA 830 HTA 830 without Base HTA 840 HTA 840 without Base 14...

Страница 15: ...s RS 485 Wiring Connection Note Assign different IDs for each HTA 810 820 830 840 recorder when there are more than one recorder in the network Default ID is 1 Set your ID with our software RS 232 Wir...

Страница 16: ...TCP IP RJ 45 Connection for HTA 830 TCP IP RJ 45 Connection for HTA 840 16...

Страница 17: ...Alarm Output Connection HTA 810 820 830 HTA 840 17...

Страница 18: ...Communication Connection RS232 RS485 Communication Port for HTA 810 820 Communication Port for HTA 830 18...

Страница 19: ...Communication Port for HTA 840 Note POE stands for transmitting DC power 19...

Страница 20: ...Power Supply Connection Note Power Supply Connection is for HTA 810 820 830 This is not applicable for HTA 840 as it uses PoE Power over Ethernet for its power supply 20...

Страница 21: ...ount it onto the wall using the screws not required for desktop use Step 3 4 Align the extrusion part of the base to HTA 810 820 recorder s slots on the edges for base installation Step 5 6 Fasten the...

Страница 22: ...840 make sure the IP port is correctly set Q I swiped the card but the device has no response A 1 Please check if the card format matches model purchased 2 Please make sure card registry process is c...

Страница 23: ...Err2 Card number contains non numeric character under compression mode Err3 Cannot overwrite memory full Err4 Memory buffer 100 full Bad0 Flash configuration area damage Bad1 Flash valid card area da...

Страница 24: ...ct This warranty does not cover damage due to improper operation or maintenance connection to improper equipment or attempted repair by anyone other than HUNDURE In no event shall HUNDURE s liability...

Отзывы: