81
Depth Offset
(Advanced)
Settings: -10.0 to +10.0 ft, or -3 to 3 m [International
Models only]; Default = 0
Depth Offset
will adjust the digital depth readout to indicate depth from the
waterline or boat's keel. Enter a positive vertical measurement from the
transducer to the waterline to read the depth from the waterline. Enter a
negative vertical measurement from the transducer to keel to read the depth
from the keel.
Temp. Offset
(Advanced)
Settings: -10.0 to +10.0 degrees, Default = 0
Temp. Offset
will adjust the temperature readout by the amount entered.
Speed Calibration
(Advanced, with Temp/Speed only)
Settings: -20% to +20%, Default = 0%
Speed Calibration
will adjust the speed readout by the percentage entered,
and will appear in the menu if a Temp/Speed Accessory is connected and the
paddlewheel has moved at least once.
Local Time Zone
(Advanced)
Settings: Various, Default = EST [UTC-5] - Eastern
Standard Time
Local Time Zone
selects your time zone in reference to the time reported by the
GPS receiver when Time+Date is selected as a Digital Readout on the Sonar
View (see
Setup Menu Tab: Select Readouts
).
Setup Menu Tab
Содержание 581i Combo
Страница 1: ...531720 1_A 581i Combo Operations Manual 581i Combo Operations Manual ...
Страница 10: ......
Страница 58: ...48 Sonar Tab Normal Mode Sonar Tab Advanced Mode Main Menu ...