31
Control Head Setup
Control Head Setup
HELIX Series
1.
X-Press Menu:
With a MEGA Live Imaging View displayed on-screen, press the
Menu key once.
2. Select MEGA Live Mode.
3. Press the RIGHT or LEFT Cursor keys to select a mode.
When you manually change the MEGA Live mode, a message box will display
reminding you to also change the transducer's installation orientation. For
instructions on changing the installation orientation, see Step 2 of
Install the
Trolling Motor Mount, Section 5: Route the Cables and Connect Power
.
Changing the MEGA Live Mode (HELIX)
4.
Close:
Press the EXIT key.
4. Confirm the Heading Sensor Operation
It is important to confirm that the Heading Sensor is installed correctly by reviewing
the heading digital readout.
NOTE:
This procedure should be performed at slow speeds, in calm, open water, in
a large area that is far from shallow water, boats, or other obstacles.
APEX/SOLIX Series
1. Press the HOME key.
2. Select Settings > General > Units > Compass > Magnetic North.
3. With a Chart View displayed on-screen, navigate the boat in a straight line,
in calm, open water at 4.5 mph. Compare the Heading digital readout on the
screen with the Course (COG) digital readout. The readouts should be within
approximately 5° of each other.
Adjust:
To adjust the zero point of the Heading Sensor, select Settings >
Network NMEA 0183 > Data Offsets. Select Heading Adjustment. Tap the on/
off button, or press the ENTER key, to turn it on. Press and hold the slider, or
press and hold the ENTER key, to adjust the setting.
If the procedure failed:
If the Heading digital readout is significantly different
than the COG, the Heading Sensor might be installed in a location with too
much magnetic interference. Check the installation location and possible
magnetic disturbances in the area.