Preparing the Humidex for Installation
Measure the required Unit height. Remember that the units cannot be higher than 3”
to 6” off the ground. This is crucial for 103 and 105 models as they are not adjustable
in height like the 209 model is. (103 Models can allow for up to 12”)
From the inside, drill a pilot
hole of approximately ¼” at
the center of the proposed
6¼” hole.
Outside the building, find the
pilot hole. Using a hole-saw,
with the pilot hole as a guide,
drill a 6¼” hole.
Brick or Concrete Wall:
There are two ways of going through brick or concrete.
The first method consists of using a hammer drill. Make holes (approximately 5/8”)
with the hammer drill 1” apart through the brick in a circular shape outlining the 6
¼” hole. Finish cutting the outer edge of the hole using a chisel. If a hammer drill is
not available, a chisel can be used. As brick is brittle chiseling from the center of the
pilot hole will chip the brick easily. Continue chiseling until you reach the outer edge
of the 6 ¼” hole.
For 209 Models: Join the 2
halves (bottom section must fit
inside the top section). Overlap
the two pieces until the desired
height is obtained. Secure the 2
halves with 9/16” screws. If
necessary, Use the cover plate to
close the gap. Using aluminum
or duct tape, seal the seam in the
back where the 2 halves join
together.
Note
: If the unit has to be shorter than 86.5”, cut the top of the bottom part.