![HULTDINS SuperSaw 350E Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/hultdins/supersaw-350e/supersaw-350e_installation-manual_2182647033.webp)
M A I N T E N A N C E I N S T R U C T I O N S
En011307a_ss350.FM
SuperSaw 350E
33
Lubrication
The saw unit should be lubricated every 8 to 200 hours of
operation depending on the conditions that the unit is
working under. The unit has 2 lubrication points as shown
here.
See ill. 12.
Note!
Use a mineral oil based grease thickened with,
or mixable with a lithium soap. The grease should be
classified as L-XCCIB2 according to ISO 6743-9.
Molybdendisulfid content max 3 %. Base fluid
viscosity 170 to 220 cSt at 40°C. NLGI class 1-2.
Strainer for chain lubrication
The strainer in the lubrication oil pump should be
disassembled and cleaned at least every 1000 hours of
operation or when necessary.
The first month of operation
Fasteners
Tightening of the all fastners should be made once a week
during the first month of operation.
ill. 12
Lubrication points
1.
Feed out rack, 1 pcs.
2.
Bearing, 1 pcs.
1
2