11
INSTALLATION
1.POWER REQUIREMENT
- AC 3 phase 400V, 50/60 HZ with a 30 amp circuit breaker is required. DO
NOT OPERATE THIS UNIT if the ACTUAL power source voltage is less than 340 volts AC or greater
than 460 volts AC.
•
High voltage danger from power source! Consult a qualified electrician for proper installation
of receptacle. This welder must be grounded while in use to protect the operator from
electrical shock.
•
Do not remove grounding prong or alter the plug in any way. Do not use any adapters
between the welder's power cord and the power source receptacle. Make sure the POWER
switch is OFF when connecting your welder's power cord to a properly grounded 380 VAC, 60
HZ, 3Phase, 30 Amp input power supply.
2. EXTENSION CORD
- We do not recommend an extension cord because of the voltage drop they
produce. This drop in voltage can affect the performance of the welder. If you need to use an extension
cord, we recommend you check with a qualified electrician and your local electrical codes for your
specific area. Do not use an extension cord over 25 ft. in length.
3. MMA mode connection method
Note: As difference of electrode, cable connecting method may be exchanged!
4. TIG mode connection method