Chapter 2---System Description
+80 V
+ 80 V supply for use by the switching supply of horizontal deflection
amplifier
Interlocks and protection:
Input
None
Outputs
and H_LOCK-: Used to shut down the switching power
supply of the horizontal deflection amplifier in the event of a loose
yoke or loose scan reverse connector. This prevents the power
supply section of the Horizontal/Vertical Deflection Board from
operating when 1 or more yoke connectors are disconnected.
/SWEEP_OK: Shuts down the video amplifiers in the event of
deflection failure (if DEFL_OK or /H_ENABLE are not present).
2-50
Model 200 Service Manual
Содержание 200
Страница 1: ...SERVICE MANUAL Model 200 Projector ...
Страница 10: ...Safety Information Model 200 Service Manual x ...
Страница 14: ...Chapter 1 Introduction 1 4 Model 200 Service Manual ...
Страница 20: ...Chapter 2 System Description Figure 2 1 Optical System Block Diagram 2 6 Model 200 Service Manual ...
Страница 79: ...Chapter 2 System Description Model 200 Service Manual 2 65 ...
Страница 121: ...Chapter 4 Maintenance Removal Replacement 4 24 Model 200 Service Manual ...
Страница 131: ...Chapter 5 Troubleshooting 5 10 Model 200 Service Manual ...
Страница 140: ...Glossary Model 200 Service Manual B 5 ...