Chapter
4---Maintenance
(Removal/Replacement)
Figure 4-12. ILA
®
Assembly top view. The overlap screws shown are
visible after the
ILA
®
assembly is removed.
4. Loosen the two wingnuts at the top of the appropriate
ILA
®
assembly (
Figure 4-12
).
5. Slide the spring clip at the top of the
ILA
®
assembly
backward (
Figure 4-12
). This will free the
ILA
®
assembly.
6. Grasp the
ILA
®
assembly by its housing and slide it out.
7. Replace the
ILA
®
in the reverse order from above.
8. Recheck convergence, shading,
ILA
®
bias and G2 and
readjust, if necessary (
User’s Guide, Sections 5.8, 5.10,
5.7, 5.9
).
9. Recheck the
ILA
®
Back Focus (
Section 3.4
) and the
ILA
®
Overlap adjustment (
Section 3.8
).
4.16 Relay Lens
To remove a Relay Lens (
refer to Figure 4-11
):
1. Remove the rear cover (
Section 4.2
).
2. Tilt up the Electronic Module (
Section 3.3
)
3. Remove the corresponding CRT Assembly behind the
Relay Lens that is to be removed.
4. Loosen the CRT Lens Stopper Ring (the thin collar just in
front of the CRT Holder knurled ring-Figure 4-11) and
slide it off the back of the Relay Lens.
Model 200 Service Manual
4-19
Содержание 200
Страница 1: ...SERVICE MANUAL Model 200 Projector ...
Страница 10: ...Safety Information Model 200 Service Manual x ...
Страница 14: ...Chapter 1 Introduction 1 4 Model 200 Service Manual ...
Страница 20: ...Chapter 2 System Description Figure 2 1 Optical System Block Diagram 2 6 Model 200 Service Manual ...
Страница 79: ...Chapter 2 System Description Model 200 Service Manual 2 65 ...
Страница 121: ...Chapter 4 Maintenance Removal Replacement 4 24 Model 200 Service Manual ...
Страница 131: ...Chapter 5 Troubleshooting 5 10 Model 200 Service Manual ...
Страница 140: ...Glossary Model 200 Service Manual B 5 ...