Chapter 3---Service Adjustments
Model 100 Service Manual
3-17
3.8 Software
Updating
The Model 100 software resides in Flash Memory and is updated via the projector's
serial Port A. To perform an update, a disk containing the updated Boot Software
(boot.hex) and/or System Software (zsys.hex) and a PC with Windows 3.1
(Windows 95/98 with Procomm Plus fax/modem software) is required to perform
update.
Boot Manager Software and System Software are separate files. Each may be
updated independently. The System Software will depend on a specific version of
the Boot Manager. Refer to the System Software release bulletin for Boot Manager
version dependencies.
To setup the PC terminal (Windows 3.1):
1.
Verify that the projector circuit breaker is off. Use a Null Modem cable to
connect a PC to the projector’s Serial Port A.
2.
Start Windows 3.1.
3.
Click on the terminal icon from the Accessories Directory.
4.
From the Terminal menu, select Settings-Terminal Emulation, click on
DEC-VT-100(ANSI) and select OK.
5.
Under Settings choose Terminal Preferences.
6.
Under Terminal Preferences the following selections are appropriate;
!
Terminal Modes=Sound, CR->CR/LF=Both off
!
Columns=80, Cursor=Block & Blink
!
Terminal Font=Fixedsys 15, Translation=None, Show Scroll
Bars=On, Buffer Lines=100
!
Use Function Arrow & Control Keys for Windows=Off.
7.
Select OK.
8.
Under Settings, select Text Transfer=Standard Flow Control. Select OK.
9.
Under Settings select Communications and choose:
!
Connector=select the PC port being used
!
Baud Rate=9600 or 19200 (depending on the System Controller
Switch block Pos 4-see note below this step)
!
Data Bits=8, Stop Bits=1, Parity=None, Parity Check=Off, Carrier
Detect=Off, Flow Control=XON/XOFF
10.
Select OK.
To setup the Model 100 Projector:
1.
Remove the System Controller/Raster Timing Generator and verify that all
the DIPswitches are in the up position. The switch in position 4 on the
switch block (see Figure 3-12) controls the baud rate for Serial Port A for
the Boot Manager and System Software. Up=9600, Down=19200. The
switch in position 4 should be in the up position.
Содержание 100
Страница 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Страница 62: ...Chapter 2 System Description 2 50 Model 100 Service Manual Figure 2 20 Backplane Board Interface Block Diagram ...
Страница 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Страница 67: ......
Страница 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Страница 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...