Chapter 3---Service Adjustments
Model 100 Service Manual
3-13
Figure 3-9
ILA
®
Assembly top view.
5.
If the overlap is at the top or bottom, make sure the projector is level. If
there is still excessive ILA
®
overlap replace the CRT/ILA
®
, there is no
adjustment for top and bottom overlap.
6.
Retighten the slotted nuts.
7.
Reset the ILA
®
biases to their previous levels from Step 1.
3.6 Front/Rear or Inverted Projection Jumper Settings
NOTE:
In the procedures below each of the jumpers mentioned have a specific
purpose: CN702 and CN701 are for the horizontal scanning jumper, CN713 and
CN714 are for the vertical scanning jumper, and CN708 and CN707 are for the
convergence jumper.
Front / Rear Jumper Setting (Horizontal Scan Reverse)
The Horizontal Scan Reversal Jumper reverses the image projection for front or
rear projection. Figure 3-13 illustrates the jumpers’ location on the Vertical
Convergence Deflection PCB.
NOTE:
When the Horizontal Scan Reversal Jumper is changed, the Front/Rear
Convergence Jumper must also be changed.
The Model 100 Projector is shipped with the Horizontal Front / Rear jumper plug
is in CN702 for front/upright projection. The Front / Rear Convergence jumper
plug is in CN708. For other orientations refer to Table 3-1.
To change the Horizontal Scan Jumper:
1.
Turn power off at the projector and wait 10 minutes for the arc lamp to
cool.
Slotted screws
Содержание 100
Страница 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Страница 62: ...Chapter 2 System Description 2 50 Model 100 Service Manual Figure 2 20 Backplane Board Interface Block Diagram ...
Страница 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Страница 67: ......
Страница 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Страница 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...