Installation
c
LeaRanceS
to
c
ombuStibLeS
:
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing,
routine cleaning, and maintenance.
Figure 4: Minimum Clearances to Combustibles for Freestanding
Kinderhook.
8
Back wall
Side wall
Adjacent
wall
2"
2"
6"
3.087
6.087
a
DjuStabLe
P
eDeStaL
/f
LooR
P
Rotection
:
If the unit is installed on combustible material, there must be a minimum of 6” of floor protection in front of the unit.
The Kinderhook has an adjustable pedestal base which has two positions. When in the forward position as shown
below, it provides 6” of floor protection and a hearth pad is not needed. The bolts for adjusting the pedestal base
are located under the unit.
Figure 5: Adjustable Pedestal Base Positions
Rear position as shipped from the factory.
Forward position providing 6” of floor protection.