11

COM Control   

In normal working mode, the camera is able to be controlled via RS-232C/RS485 command (VISCA IN) . 
The parameter of the RS232C/RS485 COM is as following :   
Baud Rate 

˖

2400/4800/9600/115200 bit/s 

Start bit

˖

1bit ; 

Data bit:    8bit ; 
Stop bit :    1bit;   
Code:          None   
Connected to power, the camera runs to the down left, then back to middle, with the farthest zoom rate in the 
auto focus and auto iris mode. After initialization,the camera runs to the preset No.0 or 1 if it is saved.Then 
the users can control the camera via serial command. 
 

VISCA Protocol 

Part1 .    Camera Return Command   

Ack/Completion Message 

 

Command Packet 

Note 

ACK 

z0 41 FF 

Returned when the command is accepted.   

Completion 

z0 51 FF 

Returned when the command has been executed. 

z = Camera A 8 

 

Error Messages 

 

Command Packet 

Note 

Syntax Error 

z0 60 02 FF 

Returned  when  the  command  format  is  different  or  when  a 
command with illegal command parameters is accepted 

Command Not Executable 

z0 61 41 FF   

Returned  when  a  command  cannot  be  executed  due  to  current 
conditions.  For  example,  when  commands  controlling  the  focus 
manually are received during auto focus. 

 

Part 2      Camera Control Command   

Command 

Function 

Commad Packet 

Note 

AddressSet 

Broadcast 

88 30 01 FF 

Address setting 

IF_Clear 

Broadcast 

88 01 00 01 FF 

I/F Clear 

CommandCancel 

 

8x 21 FF 

 

On 

8x 01 04 00 02 FF 

CAM_Power 

Off 

8x 01 04 00 03 FF 

Power ON/OFF 

Stop 

8x 01 04 07 00 FF 

Tele(Standard) 

8x 01 04 07 02 FF 

Wide(Standard) 

8x 01 04 07 03 FF 

 

Tele(Variable) 

8x 01 04 07 2p FF 

Wide(Variable) 

8x 01 04 07 3p FF 

p = 0(low) - 7(high) 

CAM_Zoom 

Direct 

8x 01 04 47 0p 0q 0r 0s FF 

pqrs: Zoom Position 

Stop 

8x 01 04 08 00 FF 

Far(Standard) 

8x 01 04 08 02 FF   

Near(Standard) 

8x 01 04 08 03 FF 

 

Direct 

8x 01 04 48 0p 0q 0r 0s FF 

pqrs: Focus Position 

CAM_Focus 

One Push AF 

8x 01 04 18 01 FF 

 

CAM_ZoomFocus 

Direct 

8x 01 04 47 0p 0q 0r 0s   
0t 0u 0v 0w FF 

pqrs: Zoom Position 
tuvw: Focus Position 

Auto 

8x 01 04 35 00 FF 

Normal Auto 

Indoor   

8x 01 04 35 01 FF 

 

Outdoor   

8x 01 04 35 02 FF 

 

OnePush   

8x 01 04 35 03 FF 

 

CAM_WB 

Manual 

8x 01 04 35 05 FF 

 

Содержание HuddleCamHD 18x

Страница 1: ...USB3 0 HD Color Video Camera User Manual English...

Страница 2: ...to avoid any damage or danger Don t expose the camera to rain or moisture place Don t remove the cover to reduce the risk of electric shock Refer servicing to qualified personnel Never operate the cam...

Страница 3: ...IES 3 FAST INSTALLATION 3 CAMERA HIGHLIGHTS 5 CAMERA SPECIFICATIONS 5 CAMERA INTERFACE EXPLANATION 6 REMOTE CONTROLLER EXPLANATION 7 USAGE OF IR REMOTE CONTROLLER 8 RS 232C INTERFACE PIN SPECS 10 COM...

Страница 4: ...or solid environment to avoid the cover which is made up of organic material To make sure no obstacle in rotation range Never power on before installation is not completed Don t dispatch discretionari...

Страница 5: ...en the power supply switch is on the indicator light is open red color 5 Confirm the computer device manager has the image device Cyt FX3 device and then you can find the Cyt FX3 device in the video c...

Страница 6: ...on mode is opened and saved preset position 0 or 1 then the pan tilt will be set to 0 or 1 preset position 10 Factory Default entry OSD menu by pressing the menu key of remote controller MENU RESET A...

Страница 7: ...2 8 Support auto manual white balance indoors out doors controller auto auto track white balance auto manual exposure iris shuttle auto manual One Push focus 9 support WDR function with performance 1...

Страница 8: ...e setting is Auto BLC OFF close black light compensation Only available in the exposure mode effective for Auto 5 Focus control key Focus focus length far from near Focus focus length near from far Au...

Страница 9: ...sequence For example F1 means press first and then press and press F1 at last 1 Pan Tilt Control Up press Down press Left press Right press Back to middle position press HOME Press and hold the up dow...

Страница 10: ...total are available 2 Preset clearing to clear a preset position the user can press the CLEAR PRESET key first and then press the number key 0 9 to clear the relative position Note press the key three...

Страница 11: ...6 DSR 7 IR OUT 7 RTS 8 RS485 B 8 CTS 9 RI Camera Mini DIN 1 DTR 1 DTR 2 DSR 2 DSR 3 TXD 3 TXD 4 GND 4 GND 5 RXD 5 RXD 6 RS485 A 6 GND 7 IR OUT 7 NC 8 RS485 B 8 NC Camera RS485 1 DTR 2 DSR 3 TXD1 4 GND...

Страница 12: ...s accepted Command Not Executable z0 61 41 FF Returned when a command cannot be executed due to current conditions For example when commands controlling the focus manually are received during auto foc...

Страница 13: ...p 8x 01 04 0C 02 FF Down 8x 01 04 0C 03 FF Gain Setting CAM_Gain Direct 8x 01 04 0C 00 00 0p 0q FF pq Gain Positon CAM_Bright Direct 8x 01 04 4D 00 00 0p 0q FF pq Bright l Positon On 8x 01 04 3E 02 FF...

Страница 14: ...FF y0 50 0p 0q 0r 0s FF pqrs Zoom Position y0 50 02 FF Auto Focus CAM_FocusModeInq 8x 09 04 38 FF y0 50 03 FF Manual Focus CAM_FocusPosInq 8x 09 04 48 FF y0 50 0p 0q 0r 0s FF pqrs Focus Position y0 5...

Страница 15: ...Address 0x00 0x14 Pan Speed Tilt Speed SUM Upleft 0xFF Address 0x00 0x0C Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF Address 0x00 0x40 0x00 0x00 SUM Focus Far...

Страница 16: ...0x00 0x03 0x00 Preset ID 0xAF XOR Clear Preset 0xA0 Address 0x00 0x05 0x00 Preset ID 0xAF XOR Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR Query Pan Position 0xA0 Address 0x00 0x51 0x00...

Страница 17: ...Reset Condition VISCA Protocol type VISCA Pelco P Pelco D ADDR Reset Condition 01 VISCA 1 7 Pelco P Pelco D 1 63 B RATE Reset Condition 9600 2400 4800 9600 115200 RS485 Reset Condition off It is ON wh...

Страница 18: ...Reset Condition Default Available 0 13 only available in Manual Iris mode BRIGHT Reset Condition 5 Available 0 9 GAIN Reset Condition Default Available 0 15 only available in Manual mode EV MODE Rese...

Страница 19: ...ing 0 9 3 3 LENS SETTING Move the pointer to the LEN SET in the Main Menu click the HOME and enter the LEN SET as follow FOCUS Auto Manual OnePush 4 PAN TILT SETTING Move the pointer to the PT SET in...

Страница 20: ...Protocol VISCA Address 1 baud rate 9600 S485 Off CAM RESET camera parameter reset PT RESET power action Off speed by zone On mount mode Up IR move speed 16 IR zoom speed 7 MIN SPEED 0 SCAN SPEED 10 A...

Страница 21: ...he power cord voltage is OK power indicator light is ON 2 Turn off the power supply to check whether the camera can auto configure 3 Check the dial switch in bottom and make sure the two dial position...

Отзывы: