ERT7 and ERT8 Ebbert Rivet Tools (HK1061)

    

Limited Warranties

Limited Lifetime Warranty on BobTail® Tools: 

Huck International, Inc. warrants to the original purchaser 

that its BobTail® installation tools manufactured after 

12/1/2016 shall be free from defects in materials and 

workmanship for its 

useful lifetime

.  This warranty does 

not cover special order / non-standard products, or part 

failure due to normal wear, tool abuse or misapplication, 

or user non-compliance with the service requirements and 

conditions detailed in the product literature. 

Two Year Limited Warranty on Installation Tools: 

Huck International, Inc. warrants that its installation tools 

and Powerig

®

 hydraulic power sources manufactured after 

December 1, 2016 shall be free from defects in materials 

and workmanship for a period of two years from date of 

purchase by the end user.  This warranty does not cover 

special order / non-standard products, or part failure due 

to normal wear, tool abuse or misapplication, or user non-

compliance with the service requirements and conditions 

detailed in the product literature. 

90 Day Limited Warranty on Nose Assemblies and 

Accessories:

 

Huck International, Inc. warrants that its nose assemblies 

and accessories shall be free from defects in materials 

and workmanship for a period of 90 days from date of 

purchase by the end user.  This warranty does not cover 

special clearance noses, or special order / non-standard 

product, or part failure due to normal wear, abuse or 

misapplication, or user non-compliance with the service 

requirements and conditions detailed in the product 

literature. 

Useful lifetime

 is defined as the period over which the 

product is expected to last physically, up to the point when 

replacement is required due to either normal in-service 

wear, or as part of a complete overhaul. Determination is 

made on a case-by case basis upon return of parts to Huck 

International, Inc. for evaluation.

Tooling, Part(s) and Other Items not manufactured by 

Huck:

 

HUCK makes no warranty with respect to the tooling, 

part(s), or other items manufactured by third parties. HUCK 

expressly disclaims any warranty expressed or implied, as 

to the condition, design, operation, merchantability, or 

fitness for use of any tool, part(s), or other items thereof 

not manufactured by HUCK. HUCK shall not be liable for 

any loss or damage, directly or indirectly, arising from the 

use of such tooling, part(s), or other items or breach of 

warranty or for any claim for incidental or consequential 

damages.

Huck shall not be liable for any loss or damage resulting 

from delays or non-fulfillment of orders owing to strikes, 

fires, accidents, transportation companies or for any reason 

or reasons beyond the control of the Huck or its suppliers.

Huck Installation Equipment:

Huck International, Inc. reserves the right to make changes 

in specifications and design and to discontinue models 

without notice.

Huck Installation Equipment should be serviced by trained 

service technicians only.

Always give the serial number of the equipment when 

corresponding or ordering service parts.

Complete repair facilities are maintained by Huck 

International, Inc. Please contact one of the offices listed 

below.

Eastern

One Corporate Drive Kingston, New York 12401-0250 

Telephone (845) 331-7300 FAX (845) 334-7333

Outside USA and Canada

Contact your nearest Huck International location (see 

reverse).

In addition to the above repair facilities, there are 

Authorized Tool Service Centers (ATSC’s) located 

throughout the United States. These service centers offer 

repair services, spare parts, Service Parts Kits, Service 

Tool Kits and Nose Assemblies. Please contact your Huck 

Representative or the nearest Huck International location 

(see reverse) for the ATSC in your area.

Содержание ERT7

Страница 1: ... ERT7 and ERT8 Ebbert Rivet Tools Safety Instructions 3 Specifications 4 Warning Stickers 4 Principle of Operation 5 Preparation for Use 5 Attaching Nose Assembly to Tool 6 Kits and Accessories 6 Troubleshooting 6 Maintenance 7 Disassembly Instructions 8 Assembly Instructions 8 Components Drawings 9 10 ...

Страница 2: ...2 ERT7 and ERT8 Ebbert Rivet Tools HK1061 ...

Страница 3: ...suitable postures as it is likely for these not to allow counteracting of normal or unexpected tool movement 8 If the assembly power tool is fixed to a suspension device make sure that fixation is secure 9 Beware of the risk of crushing or pinching if nose equipment is not fitted IV REPETITIVE MOTION HAZARDS 1 When using assembly power tool the operator can experience discomfort in the hands arms ...

Страница 4: ...PERATORS TO PREVENT PERSONAL INJURY 590561 590350 Where the following trade names are used in this manual note DEXRON is a registered trademark of General Motors Corporation GLYD Ring is a registered trademark of Trelleborg Sealing Solutions Germany GmbH Loctite is a registered trademark of Henkel Corporation U S A LUBRIPLATE is a registered trademark of Fiske Brothers Refining Co MERCON is a regi...

Страница 5: ...el EPS6V or EPS6VL that has been prepared for operation per applicable instruction manual Check incoming pressures and if necessary adjust to the recommended pressures in Specifications of this manual 2 Turn OFF the Ebbert Power Unit and then disconnect the power supply from the unit Connect the tool s hoses to the unit 3 Connect the cable attachment from hose assembly to cylinder base of tool 4 C...

Страница 6: ...reak a Improper tool operation See No 5 b Incorrect fastener size or type c PULL pressure too low 7 Pulling Head will not release broken pintail a Pulling Head assembly not correctly installed b Tool or Pulling Head may need cleaning 8 Excessive air leaking from trigger and tool will not function a Green and red air hoses may be switched Service Kit ERT7 and ERT8 300471 This kit is for both tools ...

Страница 7: ...regular retailer of these items See Parts List for O ring size AS568 number material durometer For kit parts lists and related information see Kits and Accessories PREVENTIVE MAINTENANCE System Inspection The operating efficiency of the tool is directly related to the performance of the complete system including the tool with pulling head assembly trigger control cord and Power Unit Therefore an e...

Страница 8: ...with mineral spirits or similar solvent Inspect for wear damage and replace as necessary Replace all seals of disassembled components Use O rings Quad rings and Back up rings in Service Parts Kit ERT5S7KIT or ERT8KIT Coat O rings seals Back up rings and mating parts with conventional O ring lubricant to ease assembly Assemble tool taking care not to damage O rings seals or Back up rings NOTE Insta...

Страница 9: ...66 Seal 2 10 500780 O ring 1 11 300063 Double Piston 1 12 500995 Retaining Ring 2 13 300071 Seal 1 14 300029 End Cap 1 15 506268 Male Connector 1 16 300107 Guard 1 17 300156 Valve Back up Ring 1 18 500779 O ring 1 19 300042 Handle 1 20 300251 Trigger 1 21 500623 Pin 1 22 507660 Bleed Screw 2 23 300064 Screw Bearing Plate 2 24 500064 Socket Head Screw 8 25 300114 Support Loop Assembly 1 26 500061 S...

Страница 10: ...Seal 1 14 300029 End Cap 1 15 506268 Male Connector 1 16 300037 Valve Body 1 17 300156 Valve Back up Ring 1 18 500779 O ring 1 19 300105 Handle 1 20 300252 Trigger 1 21 500623 Pin 1 22 507660 Bleed Screw 2 23 300064 Screw Bearing Plate 2 24 500064 Socket Head Screw 8 25 300126 Support Loop Assembly 1 26 500061 Socket Head Screw 4 27 508010 Piston Rod Wiper 1 28 501344 Dowel 1 29 300158 Valve 1 30 ...

Страница 11: ...rvice wear or as part of a complete overhaul Determination is made on a case by case basis upon return of parts to Huck International Inc for evaluation Tooling Part s and Other Items not manufactured by Huck HUCK makes no warranty with respect to the tooling part s or other items manufactured by third parties HUCK expressly disclaims any warranty expressed or implied as to the condition design op...

Страница 12: ...00 São Paulo SP Brazil Tel 55 11 3583 7061 Suzhou Operations 58 Yinsheng Road SIP Suzhou Jiangsu 215126 China Tel 86 512 62863800 8888 Telford Operations Unit C Stafford Park 7 Telford Shropshire England TF3 3BQ Tel 44 1952 290011 Fax 44 1952 207701 thisales arconic com Tokyo Operations Japan and Korea 1013 Hibiya U 1 Bldg Uchisaiwai cho 1 1 7 Chiyoda ku Tokyo 100 0011 Japan Tel 81 3 3539 6594 Fax...