Emergency Telephone Installation
1.
Separate the back box from the front panel of the telephone.
The parts envelope inside the back box contains eight #6-32 self-tapping flat head screws, six security
screws, six washers, and a hole plug.
2.
Place the back box into the telephone opening from the front of the station.
3.
Fasten the back box using four #6-32 self-tapping flat head screws (see Figure 7).
The telephone back box has two openings, one in the top and one in the bottom.
4.
Plug the top opening with the hole plug.
N
OTE
:
The bottom of the back box is the recommended entry location for the telephone line and
strobe control wires.
Figure 7. Telephone and Back Box Installation
5.
Install a telephone line surge suppressor (sold separately) on the protection bracket in the bottom of
the wall-mounted station assembly (see Figure 3).
6.
Install a ground wire between the telephone line surge suppressor (sold separately) and the grounding
lug in the bottom of the station (see Figure 8).
7.
Connect the telephone line to the surge protection (see Figure 8).