8.
Connect the telephone cable from the surge protection and feed the cable through the bottom access
hole of the telephone back box and allow it to hang free.
9.
Bring the orange and violet strobe unit wires through the bottom access hole of the back box and
allow them to hang free.
10.
The telephone front panel is shipped from the factory with a cable and modular plug attached to
terminal block
TB1
. If desired, an optional modular telephone jack can be mounted to the inside of
the back box allowing the use of the cable and modular plug that is attached to TB1. If the telephone
line is to be hard-wired to the telephone, this cable can be removed and discarded.
11.
Attach the telephone cable from the surge protector to terminal block
TB1
on the telephone PCBA
12.
Attach the strobe’s violet and orange control wires to terminal block
TB2
on the telephone PCBA
13.
Install the telephone’s front panel using the six tamper-resistant screws and six washers provided.
N
OTE
:
Excessive tightening will cause the panel to warp. Do not over-tighten.
Station Panel Light and Strobe Power Connections
N
OTE
:
All connections must be made in accordance with the National Electrical Code (NEC) in the
United States or the Canadian Electrical Code (CEC) in Canada.
AC installations: Install the power lines per Figure 8 for ac installations or Figure 9 for dc installations.
Figure 8. Interconnection Diagram with AC-Powered Strobe