Pub. 42004-308H
234WM-202 RED ALERT
®
Elite Wall-Mount Communication Station
Page 9 of 10
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-308H.docx
08/19
Figure 9. Interconnection Diagram with DC-Powered Strobe
Maintenance
Contact a regional service center for a return authorization number (RA#) if the equipment requires
service. Equipment must be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. Repairs or a replacement will be made in accordance with GAI-Tronics’
warranty policy if the equipment is under warranty. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 inside the USA or 610-777-1374 outside the USA for help identifying the Regional
Service Center closest to you.
Repairing Surface Damage to Powder-Coated Stations
1.
Carefully sand the damaged area to clean and score the base metal, taking care to minimize any
additional damage to the surrounding powder coating.
2.
Wipe the sanded area with a cleaning solvent, such as DuPont PrepSol
®
or equivalent. Allow the area
to dry. This type of product is normally available at auto parts stores. Denatured alcohol may also be
used.
3.
Prepare the bare metal surface for painting by treating it with a phosphoric acid solution intended for
this purpose. The phosphoric acid solution is also normally available at auto parts stores. Allow the
area to dry.
4.
Using a cotton-tipped swab or small brush, paint the prepared surface with an automotive enamel or
oil base polyurethane enamel such as Red Devil, Rustoleum, or equivalent. Do NOT use Krylon-type
paints. Carefully blend the repair enamel into the powder coat at the edges.
N
OTE
:
Exact color matches may not be attainable.