08/19
Figure 3. Conduit/Surge Protection Locations
Tempered Glass Installation
(Factory Installed)
1.
Remove the keps nuts, spacer brackets, and
holding brackets.
These parts hold the glass in place.
2.
Carefully unpack the glass from the box
located in the telephone mounting area of
the Model 234WM-202 Wall-Mount
Enclosure.
3.
Center the front glass left to right and top to
bottom around the opening in the front
panel assembly.
4.
Fasten the glass in place using the spacer
brackets, holding brackets, and keps nuts
previously removed (see Figure 4).
N
OTE
:
Do not exceed 24 in∙lb of torque on
the keps nuts.
5.
Repeat the above steps for both side glass
pieces.