o
net syslog facility set to 14
o
net syslog severity set to 5
To use the links within TMA to manage phone settings (if required), the phone web external
server enable parameter (on the Remote Configuration Access page) must also be enabled
with phone web server port set to 80.
12.
Restore to Factory defaults
With the exception of Auteldac 6, if the IP address is not known, it can be discovered by
making a USB connection as described in section 7.4 above.
The telephone can be restored to its factory defaults (ie to the configuration it had when first
delivered) as follows:
•
Auteldac 6:
o
Power off the phone
o
Press & hold the
M3
&
buttons
o
Power on the phone whilst keeping both buttons pressed
o
After 15 seconds, release the buttons
o
The phone will now load the factory default configuration and then boot up.
•
All other models:
by using the FACTORY button on the main PCB, as described in
section 7.2 above.
13.
Copyright Notices
© Hubbell Ltd., 2018-2020. All rights reserved.
The software within the product includes parts subject to other copyright as follows:
Cryptographic software copyright © 1995-1998 Eric Young ([email protected])
All rights reserved.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. All advertising materials mentioning features or use of this software
must display the following acknowledgement:
"This product includes cryptographic software written by
Eric Young ([email protected])"
The word 'cryptographic' can be left out if the rouines from the library
being used are not cryptographic related :-).
4. If you include any Windows specific code (or a derivative thereof) from
the apps directory (application code) you must include an acknowledgement:
"This product includes software written by Tim Hudson ([email protected])"
THIS SOFTWARE IS PROVIDED BY ERIC YOUNG ``AS IS'' AND ANY EXPRESS OR
IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
The licence and distribution terms for any publically available version or
derivative of this code cannot be changed. i.e. this code cannot simply be
copied and put under another distribution licence