Hubbell GAI-TRONICS 10959-001 Скачать руководство пользователя страница 32

P

AGE 

30 of 30

M

ODEL 

10959-00

W

ALL

-M

OUNT 

A

UDIO 

M

ESSENGER 

I

NTERFACE

42004-344i

d:\standard ioms - current release\42004 instr. manuals\42004-344i.doc

01/06

User Instructions (USA)

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA.  On this
equipment is a label that contains, among other information, a product identifier in the format
US:AAAEQ##TXXXX.  If requested, this number must be provided to the telephone company.

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the
applicable FCC Part 68 rules and requirements adopted by the ACTA.  A compliant telephone cord and modular
plug is provided with this product.  It is designed to be connected to a compatible modular jack that is also
compliant.  See installation instructions for details.

The REN is used to determine the number of devices that may be connected to a telephone line.  Excessive RENs on
the telephone line may result in the devices not ringing in response to an incoming call.  In most but not all areas, the
sum of the RENs should not exceed five (5.0).  To be certain of the number of devices that may be connected to a
line, as determined by the total RENs, contact the local telephone company.  For products approved after July 23,
2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX.  The
digits represented by ## are the REN without a decimal point (e.g., 03 is an REN of 0.3).  For earlier products, the
REN is separately shown on the label.

If this equipment [GAI-Tronics telephone] causes harm to the telephone network, the telephone company will notify
you in advance that temporary discontinuance of service may be required.  But if advance notice isn’t practical, the
telephone company will notify the customer as soon as possible.  Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect
the operation of the equipment.  If this happens the telephone company will provide advance notice in order for you
to make necessary modifications to maintain uninterrupted service.

If trouble is experienced with this equipment [GAI-Tronics telephone], for repair or warranty information, please
contact GAI-Tronics Corporation at 800-492-1212 or www.gai-tronics.com.  If the equipment is causing harm to the
telephone network, the telephone company may request that you disconnect the equipment until the problem is
resolved.

Connection to party line service is subject to state tariffs.  Contact the state public utility commission, public service
commission or corporation commission for information.

This equipment uses a telephone handset and it is hearing aid compatible.

User Instructions (Canada) CP-01, Issue 8, Part I:  Section 14.1

NOTICE:  

The Industry Canada label identifies certified equipment.  This certification means that the equipment

meets certain telecommunications network protective, operational and safety requirements as prescribed in the
appropriate Terminal Equipment Technical Requirements document (s).  The Department does not guarantee the
equipment will operate to the user's satisfaction.  Before installing this equipment, users should ensure that it is
permissible to be connected to the facilities of the local telecommunications company.  The equipment must also be
installed using an acceptable method of connection.  The customer should be aware that compliance with the above
conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be
coordinated by a representative designated by the supplier.  Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to
disconnect the equipment.  Users should ensure for their own protection that the electrical ground connections of the
power utility, telephone lines and internal metallic water pipe system, if present, are connected together.  This
precaution may be particularly important in rural areas.

CAUTION

Users should not attempt to make such connections themselves, but should contact the appropriate electric
inspection authority, or electrician, as appropriate.

CP-01, Issue 8, Part I:  Section 14.2

NOTICE:

  The 

Ringer Equivalence Number

 (REN) assigned to each terminal device provides an indication of the

maximum number of terminals allowed to be connected to a telephone interface.  The termination on an interface
may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence
Numbers of all the devices does not exceed 5.

Содержание GAI-TRONICS 10959-001

Страница 1: ...l Output Connections 9 TB2 Digital Input Connections 10 TB3 Audio Output and Data Connections 11 TB4 Reboot and Fault Output 12 TB5 Auxiliary Audio 13 TB6 Power Connections 14 Telephone Line Connection 14 Page Party System Connections 15 Setup 17 Preparation 17 Setting the Date and Time 18 Initiating a Page 18 Verifying Telephone to Page Party Operation 19 Operation 20 LCD Display and Push button ...

Страница 2: ... WALL MOUNT AUDIO MESSENGER INTERFACE d standard ioms current release 42004 instr manuals 42004 344i doc 01 06 Internal Cable Connections 28 External Components 29 SmartMedia Card Slot 29 LCD Display 29 Replacement Parts 29 Confidentiality Notice 29 ...

Страница 3: ... messages for many applications The following is a sample of the included and optional features AMI Configuration Tool Software complete with Pre recorded alarm tones Pre recorded speech messages 8 inputs outputs plus expansion option Real time clock Option to route audio to 8 individually controlled zones Scheduled events Live speech messages Telephone access with built in feedback eliminator Sec...

Страница 4: ...te alarm systems interface to automated processes interface to paging system equipment etc If the standard eight inputs are not sufficient for an application the AMI can support the addition of one Model 12584 001 I O Control Module The I O control module includes 32 inputs and 32 digital outputs expanding the total I O to 40 each The Real Time Clock provides the AMI the capability to broadcast an...

Страница 5: ...to gain access to the system Day and Night modes can have different security codes The Model 10959 001 and 10959 003 each includes a Page Party system Interface card This interface card provides the capability to broadcast any audio generated by the AMI on a GAI Tronics Page Party system When coupled with a telephone interface card the Page Party card provides telephone callers access to full dupl...

Страница 6: ...m output Zones can be assigned to zone groups via the ACT tool A maximum of 60 zone groups can be created Each zone group has a unique description and can consist of any combination of output zones The ACT tool provides configuration of zone groups which can then be assigned to various events and messages Via the remote control function the caller has the option of choosing the zone group destinat...

Страница 7: ...Tone Speech Generator 33 ohm Page Party Interface 10959 002 AMI Wall Mount Tone Speech Generator 600 ohm Interface 10959 003 AMI Wall Mount Tone Speech Generator Telephone Interface 33 ohm Page Party Interface 10959 004 AMI Wall Mount Tone Speech Generator Telephone Interface 600 ohm Interface 10960 001 Zone Interface Module including the Amplifier Steering Module The wall mount AMI includes a fro...

Страница 8: ... Approvals Safety of Information Technology Equipment UL 60950 CAN CSA C22 2 No 60950 00 IEC 60950 FCC Information Complies with CFR47 Part 15 Class A FCC Registration Number US ADGOT01B46055 Ringer Equivalence REN 0 1B Telephone Network Interface Telephone Central Office Line or PBX USOC RJ11 jack using 2 wire loop start bridged ringing circuit IC Information Canada IC Certification Number 822118...

Страница 9: ...impedance Party line 33 ohm nominal ac source impedance Page line output level Adjustable 1 5 VRMS nominal Inputs outputs Page line 5 party lines audio level 1 5 VRMS maximum Audio to from AGI Main and Page Party PCBA 1 0 VRMS maximum Controls POT1 audio level to party line POT2 audio level to page line Installation Power Disconnect The power cord is the main power disconnect for all units Disjont...

Страница 10: ...ize hole s in the enclosure 5 Use Myers ST 4 1 25 inches Scru Tite hubs or equivalent Reducers must be used for smaller conduit sizes to ensure proper contact with the supplied grounding plates The hub s must be connected to the conduit before being connected to the enclosure 6 Each mounting hole in the enclosure is 0 280 inch in diameter Secure the rear enclosure on the wall with screws or approp...

Страница 11: ...odel 12584 001 I O Control Module please refer to Pub 42004 359 for installation connection and specification details NOTE All outputs are programmed using AMI Configuration software Each output must be programmed before it can activate Terminal Labeled Function Type TB1 1 COMMON Ground DC power supply common TB1 2 AUX OUTPUT 1 Output 1 Idle V dc active low sink100 mA maximum TB1 3 AUX OUTPUT 2 Ou...

Страница 12: ...etails NOTE For the inputs to operate reliably the cable loop resistance connecting the relay switch contact closures cannot exceed 200 ohms For example using 24 AWG cable the maximum cable length for connection of the relay switch contact closures cannot exceed 1 500 feet Refer to the TB2 terminal block assignment chart and Figure 3 below Terminal Labeled Function Type of Source TB2 1 COMMON Grou...

Страница 13: ...vided to drive a power amplifier Refer to the TB3 terminal block assignment chart and Figure 4 below Terminal Labeled Description Function TB3 1 LINE Page L1 TB3 2 LINE Page L2 Audio output line level to public address amplifier Refer to Figure 4 TB3 3 L1 Audio 2 L1 TB3 4 L2 Audio 2 L2 No customer connections used for internal connections to Telephone Interface PCBA TB3 5 L1 Audio 1 L1 TB3 6 L2 Au...

Страница 14: ...is operating the fault output is on TB4 4 active low and can be used to energize external relays or indicating devices When a fault is detected that prevents the AMI processor from functioning the output is turned off pulled high Refer to Figure 6 and TB4 SYSTEM terminal block assignments below which provide the following external control functions NOTE For the inputs to operate reliably the cable...

Страница 15: ...Figure 6 for typical connection TB4 5 REBOOT System reboot When AMI is operating this pin is 5 V dc To reboot the AMI momentarily connect this pin to TB4 6 Refer to Figure 5 for typical connection TB4 6 GND Power ground Power supply common TB4 7 Relay N O TB4 8 Relay com Solid state relay closure On resistance 30 ohms When AMI is playing a message this contact is closed TB5 AuxiliaryAudio The TB5 ...

Страница 16: ...on TB6 1 Power 12 to 24 V dc power supply positive terminal TB6 2 Power 12 to 24 V dc power supply negative terminal TB6 3 Ground Earth ground TelephoneLineConnection For AMI units equipped with a Telephone Interface board 69501 xxx Models 10959 003 and 10959 004 connections are made to a standard PBX analog station port or directly to a central office CO telephone line For the Models 10959 003 an...

Страница 17: ...y Interface PCBA Refer to Figure 8 for connection locations and to Figure 9 for the terminal block location The connections to the page and party audio lines of the system should be made to the nearest handset or speaker station in the Page Party system For the Model 10959 001 only the page line is connected See Figure 8 For Model 10959 003 the page and five party lines can be connected The party ...

Страница 18: ...B1 10 PARTY 4 L2 Connects to party line 4 of the Page Party system TB1 11 PARTY 5 L1 TB1 12 PARTY 5 L2 Connects to party line 5 of the Page Party system Resistive line balancing is required for the page line If the AMI is installed in an existing or new Page Party system with a Model 305 001 Line Balance no additional line balancing is required However if no resistive line balance exists a 33 ohm ...

Страница 19: ... is installed and connections are made consistent with the Installation section on page 7 Please verify the following DC power connected and polarity is correct Inputs are connected Outputs are connected Phone line is connected if applicable Page and party lines are connected if applicable Paging amplifier is connected if using 600 ohm output Resistive line balance is installed to support the Page...

Страница 20: ... version if Page Party board installed Time Party Line and Page Symbol AMI Main board firmware version Time Party Line and Page Symbol Telephone Interface Mode default is Page Party mode Time Party Line and Page Symbol Telephone Interface Board firmware version if Telephone Interface Board installed Time Party Line and Page Symbol default is no greeting Telephone Interface Greeting file name this ...

Страница 21: ...arts flashing again and LED 6 goes off Party line 1 LED LED 2 will come on Figure 10 69502 xxx Page Party Interface PCBA After the telephone and Page Party system interconnections have been made call the AMI The AMI auto answers after two rings Using the AMI factory default configuration a high low tone is played to let you know to start making your page When the party line is picked up a dual ton...

Страница 22: ... indicates the AMI unit is being accessed via a telephone connection for a page or for a telephone to party conversation Microphone indicates a page from the auxiliary jack Speaker indicates a page is being sent to the page output of the AMI Right Left Arrow Indicators indicate transmit and receive activity on the auxiliary jack Text Display scrolling displays current system status such as the nam...

Страница 23: ... set the desired time ENTER to enter the menu system SELECT to scroll the menu to the Time item ENTER to select the Time item ENTER to confirm selection to select desired hour value SELECT to scroll to minute value to select desired minute value ENTER to accept the new time setting Date This menu selection is used to set the date for the AMI This button sequence allows the user to set the current ...

Страница 24: ...o the Stop item ENTER to select the Stop item ENTER to confirm the selection P P 50KHz VLC Tone This menu item is used to enable or disable a sustained 50 kHz VLC tone on the Page Party board ENTER to enter the menu system SELECT to scroll the menu to the PP 50KHz VLC Tone item ENTER to select the PP 50KHz VLC Tone item Toggle 50KHz VLC Tone scrolls across the display SELECT to scroll to select St...

Страница 25: ...ons This button sequence is used ENTER to enter the menu system SELECT to scroll the menu to the Clear Options item ENTER to select the Clear Options item Clear Hardware Options will show on the display ENTER to confirm the selection Firmware Update This menu item provides the means for updating the firmware of the AMI main board This button sequence is used ENTER to enter the menu system SELECT t...

Страница 26: ...s on page 23 to reboot the system so the memory card will be read by the AMI unit SavingConfigurationstoaSmartMedia Card Custom configurations are created using the ACT software After a custom configuration is created it must be compiled to the local hard drive typically in the C Program Files AMI Configuration Tool AMI Configs folder After the configuration is compiled to the hard drive it must b...

Страница 27: ...programmed with several parameters such as Title containing a brief text description of the input and its use The type of switch contact being used to activate the input normally open closed The action of the switch maintained momentary toggle on off Function of the input activate a message reboot mute etc 4 Output Each output circuit must be enabled or disabled If enabled it must be programmed wi...

Страница 28: ...lephone conversation After entering remote control mode the caller enters a DTMF followed by the single digit party line 1 through 5 The AMI will continue with live page or recorded paging depending upon the configured page mode When the page is answered the caller is connected to the selected party line The Off hook Timeout setting for the Telephone Interface in the ACT tool limits the duration o...

Страница 29: ...cription of Major Components InternalComponents The AMI contains the PCBAs as listed below Refer to Figure 11 and Figure 12 for mounting locations 69500 xxx AMI Main Board contains the SmartMedia memory card reader the four user push buttons and the audio accessory jack 69517 xxx Termination PCBA contains six plug in connectors accessible through the rear panel and an internal power terminal strip...

Страница 30: ...ions The following is a matrix showing the connections for the AMI internal components PCBA Component Connector Matrix AMI Main PCBA P501 P502 P3 P4 P70 P8 TB1 AMI Telephone Main Module P4 P3 Page Party Interface PCBA P4 P5 Display Module CABLE AMI Termination PCBA P8 P1 TB7 NOTE P1 cable connector is not keyed Please ensure the red striped wire in the ribbon cable is adjacent to pin 1 of the ribb...

Страница 31: ...on See Working with SmartMedia on page 24 LCDDisplay The LCD display on the front panel indicates the current day and time along with the AMI status Please refer to the Power Up section on page 18 and the LCD Display and Push button Operation section on page 20 for details regarding display messages Replacement Parts ModelNumber Description 69517 101 Termination PCBA 69501 101 Telephone Interface ...

Страница 32: ...s equipment GAI Tronics telephone for repair or warranty information please contact GAI Tronics Corporation at 800 492 1212 or www gai tronics com If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility com...

Страница 33: ... be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every claim by Buyer alleging a defect in the goods and or services provided hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above ...

Отзывы: