installations must be protected with drip pans and drains just as the codes call for protective 
requirements used in regular hot water tank installations. Buyer hereby accepts the entire 
responsibility for ascertaining whether they have sufficient electrical power to operate our 
Tankless Water heaters as indicated in our specifications which are readily available at our 
website, in our brochures and contained in the shipping box for installers to read before 
installation. If Buyer has purchased without first ascertaining the cost for installation or the 
necessary power available for operation, Hubbell at its sole and complete discretion may 
allow a return and grant a refund less freight and less 30% of the retail price as a restocking 
fee. The refund will be conditioned upon a determination by Hubbell after inspection of the 
Product being returned (either unopened or in the original shipping box and packing) that the 
Product has not been damaged. This request and for this reason only must be made within 30 
calendar days of receipt of the Product. 

 

AFTER 30 CALENDAR DAYS FROM DATE OF PURCHASE THERE WILL BE NO 
RETURNS WHATSOEVER. BUYER ACCEPTS ALL SALES AS FINAL. ANY 
ALTERATION TO THE PRODUCT VOIDS ALL WARRANTIES. HUBBELL IS NOT 
RESPONSIBLE FOR ANY OTHER CHARGE OR EXPENSE INCURRED OTHER 
THAN THE ORIGINAL PURCHASE PRICE OF THE PRODUCT.  Hubbell shall not be 
liable for consequential, special, incidental or contingent expenses or damages arising 
directly or indirectly from any defect in or use of the Product nor will Hubbell be liable for 
any water damage arising directly or indirectly from the use of the Product or from the failure 
of or defect in any component part or connecting plumbing. Hubbell and Buyer agree to  
these and the above terms in their entirety and accept all sales as final without recourse to a 
credit card company and hereby agree that this Manufacturer's Limited Warranty shall be 
governed by the laws of the State of Connecticut any and all actions arising from or relating 
to this Manufacturer’s Limited Warranty and any aspects of the Product shall be brought in a 
court of competent jurisdiction in Fairfield County, Connecticut. 

 

WARRANTY PROCEDURE 

 

4.

 

PARTS REPLACEMENT PROCEDURE (Under Warranty within 1 Year): 

Have 

your licensed electrician determine the exact parts that are defective and require 
replacement. Please note that technical support is available for qualified technicians only 
(licensed electricians and/or plumbers). Technical support that involves potentially 
dangerous electrical conditions is not available to an unqualified person. When contacting 
Hubbell, please be sure that the technician has read the “Operation and Maintenance 

Manual” and has written down all the data from the Advanced Troubleshooting Section. 

 

If, at the sole discretion of Hubbell, a component requires repair or replacement under the 
terms of this Manufacturer’s Limited Warranty, the part must be purchased and paid for 
under our “Bill and Credit” terms and will be shipped via standard ground delivery. All 
shipping charges are not included and are the responsibility of the Buyer. If faster shipping 
service is desired, the Buyer must select and pay for same. 

 

The replacement part purchased under our “Bill and Credit” terms is purchased via credit 
card and upon return of the defective parts Hubbell will determine the cause of failure, and if 
under warranty will issue a full credit less shipping charges. The returned part must be 
received by Hubbell within thirty (30) days of shipment of the replacement part. Hubbell 
will evaluate the returned part within ten (10) days, and if determined to be defective and 
covered under terms of this warranty, full credit for the part will be issued. 

Return warranty parts to: Hubbell Electric Heater 

ATTN: Tankless Warranty 
45 Seymour Street 
Stratford, CT 06615 

Содержание ETXA Series

Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TXA ETXA MTXA TANKLESS WATER HEATER ELECTRICHEATERCOMPANY Edition 2019 ...

Страница 2: ...l localmeans ofdisconnectionofallungrounded conductorsmustbeprovidedthatis within sight oftheapplianceor a circuit breakerlockout mustbeused Ref NEC 422 31 8 If theHubbell TanklessWater Heater is installed in a locationwherewater damage could occur in theevent of a leak it is recommended thata drip panbeinstalled and connected to a suitabledrain Alternatively an activewaterleak detectorandshutoff ...

Страница 3: ...nting Instructions 9 Plumbing Installation Instructions 10 Flushing the Line 10 Checking for Leaks and Purging Air 10 TypicalAccessory Piping 11 ElectricalInstallation Instructions 12 WIRING DIAGRAMS 13 SECTIONIV OPERATIONAND MAINTENANCE 27 Maintenance 27 First Use of your Hubbell Tankless Water Heater 27 Temperature Controller User InterfaceInstructions 28 Configuration Menu 28 Power and Triac Wi...

Страница 4: ...ensor within theheaterrecognizes thedemandandinitiates theheatingprocess This sensor measures thewaterflow ratewhiletwo othersensorsmeasure the incoming and outgoing water temperature This information is transmitted continually to the microprocessor controller which determinesthepreciseamountofpower tosend tothe heatingelements to heat thewater tothedesired temperature TheHubbelltankless water hea...

Страница 5: ... Frequency 50 60 Hz Protection Thermal AutoReset ProductOverview TXA MTXA Notes 1 Transformersareonlyinstalledon 3 phasemodelsover240volts 2 Systemcomponentsandlayoutaresubjecttochangewithoutnotice Hi Limit Switches Heating Elements ElementSwitching Devices Triacs Transformer Flow Meter Control Board Control Fuse GroundLug PowerDistribution Block Magnetic Contactor Heating Chamber VentDrain Cold W...

Страница 6: ...verview ETXA Notes 1 ConstructionofETXA is similar to TXA with theadditionofa mechanicaltempering valve factory set at 85 F 2 System componentsand layoutaresubject to changewithoutnotice Mechanical TemperingValve ...

Страница 7: ...7 TanklessWaterHeater Maximum Flow Rates 1 For alternatepower kW values themaximumflow ratecan becalculatedusingthe formulasonthefollowingpage ...

Страница 8: ...nga 27 kW unit when actualvoltageis 212 V 2122 44 944 0 78 27 000W 21 060 W 212 V 2402 57 600 AmperageFormula Watts Amps SinglePhase Watts 1 73 Amps 3 Phase Volts Volts Flow RateFormulas To determinepower kW requirement GPM F T 0 1465 kW To determinetemperaturerise kW 6 824 GPM F T To determineflowrate kW 6 824 F T GPM ...

Страница 9: ...trical panel this willreducetheamountofwireneeded to install and thatis physically closeto thehot water fixtures By locatingtheheater closeto thepointsofuse this will reducethe amount oftimeit takes for thehot waterto travelfrom thewaterheater to the point ofuse Consideration should alsobegiven to futureservicing Do NOT locate the water heater in a location that is difficult to access or on a hori...

Страница 10: ...th the inlet side and outlet piping of unit WARNING DO NOT SUPPLY WATER TO THE UNIT THAT IS HOTTER THAN 130 F Flushing theLine Before connectingthe copper pipeto thewater heater it is extremely important to flush the lines to eliminateall plumbingpaste residue or debrisin thelines and damagingthe flow meter After completingplumbinginstallation open thehot water faucet and allow water to run throug...

Страница 11: ...onal Temperature and Pressure Gauge Optional Ball Valve Recommended Pressure Relief Valve If requiredbycode TanklessHot Water Valve with Purge valve Connection Optional UnionFittings Strainer Recommended Water Treatment Optional Air Separator Recommended ...

Страница 12: ...rcuit breaker or bya multiplefeed installation with multipledouble polecircuit breakers Wiring to the water heater Connect the power wire from the main panel to the power distribution block or magneticcontactor as applicable Connect themain ground wire to the ground lug in the heater Make surethe connections aresecurely tightened Electrical Specifications Tanklesswaterheatersareconsidered a non co...

Страница 13: ...13 WIRING DIAGRAMS Tankless Wiring Diagram 1B ...

Страница 14: ...14 Tankless Wiring Diagram 1C Delta ...

Страница 15: ...15 Tankless Wiring Diagram 1C Wye ...

Страница 16: ...16 Tankless Wiring Diagram 1F ...

Страница 17: ...17 Tankless Wiring Diagram 1G Delta ...

Страница 18: ...18 Tankless Wiring Diagram 1G Wye ...

Страница 19: ...19 Tankless Wiring Diagram 2C ...

Страница 20: ...20 Tankless Wiring Diagram 2D ...

Страница 21: ...21 Tankless Wiring Diagram 2E Delta ...

Страница 22: ...22 Tankless Wiring Diagram 2E Wye ...

Страница 23: ...23 Tankless Wiring Diagram 2F ...

Страница 24: ...24 Tankless Wiring Diagram 3A Delta ...

Страница 25: ...25 Tankless Wiring Diagram 3A Wye ...

Страница 26: ...26 Tankless Wiring Diagram 3B ...

Страница 27: ...nanceis performed on thewaterheateror theplumbingsystem that may introduceair into thewater supplypipes it is important toturn thepower offto thewater heater and purgetheair out ofthelines beforerestoringpower to theunit See Checkingfor Leaks and PurgingAir in Section III First Use of yourHubbellTanklessWaterHeater Once thewater supplyis on and air hasbeen purged from thesystem powertheunit on at ...

Страница 28: ...s presstheUP or DOWNkey h When the desired settingis displayed simultaneously presstheUP and DOWN buttonsto lock in theselection and returntotheconfigurationmenu i Configuration Menu Items i Power Setting Sets thetotalkW ratingofwaterheater 1 where is adjustable from 001 to 164 Note that thekW selection should equalthekW based upon theactual voltagemeasured totheheater Pleasesee thenameplate on th...

Страница 29: ...iii Low High Flow Sets theunit as either a low flow or high flow unit 1 LF for low flow FactoryDefault 2 HF for high flow ix RemoteControl Setstheoperation oftheremotecontrol function seePriorityandRemoteControlsin this section 1 iPOF disables the remote control Factory Default 2 iPHi 24VDC signal connected to P1 and P2 or closed relay connected to P2 and P3 will allow the heater to operateand los...

Страница 30: ...splaywillcontinueto scrolluntileithertheUP orDOWN button is pressed and willthen returnto normaldisplaymode 5 Power RateDisplay a Thedecimal pointin thedisplay srightmost digit is a visual indicator ofhow muchpoweris required tomeet thedemand A blinkingdecimalpoint indicates thatthetriacis beingsent a signalto energizeand thus turntheelement on The decimal pointlight willblink at a faster rateas t...

Страница 31: ...roverthatdeviceto ensurethatboth do not operateatthesametimeand orthetanklesswaterheatermaybewiredtoa remote switch relay orprovidedwitha 24VDC signal suchasfroma buildingmaintenancesystem to allow thetankless waterheatertoberemotelycontrolled Thediagramanddescription below providedetailson how connectionstothetanklesswaterheatercontrolboardaretobe made 1 PriorityRelay 10A 240VACmax a When theunit...

Страница 32: ...32 Power and Triac Wiring TK2000ControlBoardWiringDetail ...

Страница 33: ...33 TK2250ControlBoardWiringDetail ...

Страница 34: ...er Yes Is control fuse open No Replace Fuse See Advanced Troubleshooting No No Is an anti scald or temperingvalve installed Yes No Does i match the actual inlet temp Yes Does o match the actual outlet temp Yes With water flowing does F show 00 0 No No Yes No See Advanced Troubleshooting Reduce flow Is flow too great for temp setting See Section II Yes Adjust temperatu re setting See Section III Is...

Страница 35: ...contactor asapplicable 5 Verify allconnections aretight Check the Power Supply to theUnit 1 Wearingproper P P E turnon power totheunit by meansofdisconnect 2 Check theincomingvoltagebetween each phaseat thelinesideof thepower distributionblock ormagneticcontactor as applicable 3 If no voltageis present between allphases verifythatthecircuit breakersatthe main paneland ordisconnect meanson havebeen...

Страница 36: ... correct voltageis present at thebottomofthehi limit thermostat butno voltageis present at thetop ofthethermostat then thathi limit thermostatneeds tobereplaced 4 If correct voltageis present on thetop andbottomcontinueto Check theThermistor 5 For three phaseunits ifthemagneticcontactor is pulled in continueto Checkthe Thermistor Otherwise startingat thelower connectionon theleft side hi limit the...

Страница 37: ...ith the settingat OHM or placeoneprobeon theend of onewire and theother probeon theend of the other wire An ohmreadingconsistent with the chart below for theapproximatetemperatureof thewater should beindicated NOTE Alligator clips shouldbeused Holdingthewires in your hands willgivea false reading Reconnect the wires 6 Repeat theabovestep with thelower terminalblock JP1 inlet thermistor 7 If either...

Страница 38: ...voltagereadings areacceptable proceed to Check theTemperatureController Check theTemperatureController TK2000ControlBoard 1 With no flow to the heater 2 At thetop ofthetemperaturecontroller thereare4 sets ofterminal blocksfor the TK2000controlboard verify the wiringis correct as indicatedin thewiringdiagram specificto your heater model 3 Check thevoltageon the2 connectionslabeled A and B on termin...

Страница 39: ...thattheoppositeend is properly connectedto thepower distributionblock magneticcontactor or transformer as applicable Also check the controlfuselocated next to thecontrolboard 4 If voltageis presentwheretheblack wires connect to theterminalsand thereis no display replacethetemperaturecontroller 5 Next check thevoltagebetween JP4andJP7 JP8andJP9 To checkthisvoltage placea probeontheYELLOW terminalof...

Страница 40: ...a clamp onmulti meter clamp themeteraroundone of thewires goingto theheatingelements The reading should beas indicated 5 based on thespecific model listed in theElectrical Specificationtablein the Installation section 4 Repeat foralltheheatingelements 5 If any amp readingis not within therangeas indicated in the chart thatheating element should bereplaced 6 If allreadings arewithinrangecontinueto ...

Страница 41: ...screwtheelementfromtheheatingchamber Installthereplacement heatingelementby screwingit intothe heatingchambercoupling NOTE VerifythattheO ringis installedontotheheatingelement priortoinstallation Re connectthepowerleads to theelementterminals Closedoor Open thecold water inlet andhotwateroutlet valves Bleed air from theunit SeeCheckingfor Leaks andPurgingAir in Section III Turn on power Hi LimitSw...

Страница 42: ...or Screw in new outletthermistorandsecurethe outletthermistorwireto the outletpipewitha new tie strap Connect thenewoutlet thermistorwires toterminals markedJP2onthetemperaturecontroller Closedoor Turn on power Inlet Thermistor TemperatureController Disconnect power Open door Mark thewires goingtothecontrollersothey canbere connectedin thesameplaces upon replacement Disconnect allthewiresfromtheco...

Страница 43: ... Flow Meter Disconnect power Shut offcold water inlet and hotwateroutlet valves Drain unit Open door Disconnect theflow meter wires fromthe controller NOTE Thedisplaymayneed toberemovedto accessthewiresfromtheflowmeter Thedisplay can beremovedby removingthefour 4 screwssecuringthedisplay to thecontrollerstandoffsandthenpullingthedisplayfromthe socket Disconnect thecold water supplypipefromthequick...

Страница 44: ...melocationstheywere previouslydisconnectedfrom Closedoor Turn on power Transformer Disconnect power Open door Mark thewiresgoingtothetransformerso they can bere connectedin thesameplaces upon replacement Disconnect allthewiresfrom the transformer Removethetwo 2 screwssecuringthe transformertothebase Installthereplacement transformerwiththe two 2 screwsremovedin thelaststep Re connectthewiresto the...

Страница 45: ...s removed from thelast step Re connect thewires to theLWCO in thesame locationsthey werepreviously disconnected from Closedoor Turn on power Low Water Cut off LWCO Probe Disconnect powerand shutoffwater Open door LocateLWCO probein thetop oftank 1 Disconnect wirefrom LWCO probe Removeprobefrom tankand installnew probewith thread sealant Reconnect wireto LWCO probe Closedoor Turn on power LWCO Prob...

Страница 46: ...6 8000 Watts 346V 3 phase N1375 8000T6 9000 Watts 346V 3 phase N1375 9000T6 8000 Watts 208V 3 phase N1375 8000R 9000 Watts 208V 3 phase N1375 9000R Extra O Ring O RING SGB Electrical Thermistor USP9509 Thermistor for ETX 1 8 NPT USP12197 Auto Resetting Hi Limit Supplied with Leads set to 140F L60 Auto Resetting Hi Limit Supplied with Leads set to 200F L93 Manual reset high limit 20615L11 C85 Tempe...

Страница 47: ...ROPERTYRIGHT INFRINGEMENT 2 LIMITATION OFREMEDIES ANDDAMAGES Hubbell s liabilityandBuyer s exclusiveremedy hereunder willbelimited solely at Hubbell s option to repair or replacement by theHubbell ServiceCenterwithrespect toanyclaim madewithinthe applicablewarrantyperiodreferred toabove Without limitingthegeneralityofthe foregoing allwarranty itemsshallbereturned by Buyer at its soleexpense to the...

Страница 48: ...les as finalwithoutrecourseto a credit card companyandhereby agreethatthisManufacturer s Limited Warranty shallbe governed by thelaws oftheStateofConnecticut anyandallactionsarisingfrom or relating to this Manufacturer sLimited Warrantyandany aspectsoftheProduct shallbebrought in a court ofcompetent jurisdictionin Fairfield County Connecticut WARRANTYPROCEDURE 4 PARTS REPLACEMENTPROCEDURE UnderWar...

Страница 49: ...49 NOTES ...

Страница 50: ...50 NOTES ...

Страница 51: ...51 NOTES ...

Страница 52: ...52 P O BOX 288 STRATFORD CT 06615 0288 PHONE 203 378 2659 FAX 203 378 3593 INTERNET http www hubbellheaters com ...

Отзывы: