TABLE OF CONTENTS
SECTION TITLE
PAGE
#
I GENERAL
INFORMATION
6
II INSTALLATION
GUIDELINES
8
III
SCHEDULED MAINTENANCE AND OPERATION
14
IV TROUBLESHOOTING
16
V
SERVICING AND REPLACEMENT OF PARTS
17
VI WARRANTY
21
4
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER BASE MODEL CE110 2009 Edition...
Страница 2: ...93 INTERNET http www hubbellheaters com IMPORTANT Always reference the full model number and serial number when calling the factory The following information should be noted at time of installation an...
Страница 3: ...d casualties always turn the power supply safety switch to off turn the charge or ground the circuit before performing any maintenance or adjustment procedure 7 This appliance is designed to store wat...
Страница 4: ...OF CONTENTS SECTION TITLE PAGE I GENERAL INFORMATION 6 II INSTALLATION GUIDELINES 8 III SCHEDULED MAINTENANCE AND OPERATION 14 IV TROUBLESHOOTING 16 V SERVICING AND REPLACEMENT OF PARTS 17 VI WARRANTY...
Страница 5: ...s heavy gauge steel finished with high gloss enamel Insulation consists of high density fiberglass blankets Temperature Pressure Safety Relief Valve Hot Water Outlet Cold water inlet not shown on bott...
Страница 6: ...overflow line should be utilized from the relief valve outlet to a floor drain See drawing for locations and sizes HEATING ELEMENT The water heater is supplied with either a 1000 watt or a 450 watt e...
Страница 7: ...r Relief Valves and Automatic Gas Shutoff for Hot Water Supply Systems ANSI Z21 22 1971 A relief valve is designed to discharge excessively hot water THE CUSTOMER IS RESPONSIBLE TO PROTECT PROPERTY AN...
Страница 8: ...alve and tank or in the drain line FILLING THE HEATER 1 Completely close the drain valve 2 Open the highest hot water faucet to allow all air to escape from piping 3 Open the valve to the cold water i...
Страница 9: ...ld water line f Hot water line connected to hot water outlet on tank g Temperature and pressure relief valve installed h Relief valve overflow line installed i Water heater filled with water j Power l...
Страница 10: ...ION WITHOUT TEMPERING VALVE Piping to Hot Water Piping from Cold Water Air Gap Drain Valve Relief Valve Discharge Pipe Temperature Pressure Relief Valve Support Bracket bottom bracket not shown Floor...
Страница 11: ...TH TEMPERING VALVE Piping to Hot Water Tempering Valve Support Bracket bottom bracket not shown Air Gap Floor Drain Relief Valve Discharge Pipe Temperature Pressure Relief Valve Piping from Cold Water...
Страница 12: ...ly clicks off draw water from heater c Measure the maximum temperature with an accurate thermometer d If the temperature is above the safe limits for your circumstances call a service man to adjust or...
Страница 13: ...mit switch tripped Reset high limit switch Loose wires Tighten wires Torque screws per torque chart included in Section VI Heating element inoperable Check heating element operation by clamping an Amp...
Страница 14: ...screws 5 Replace control and install new high limit switch by performing above steps in reverse order refer to wiring diagram in Section II Torque screws per chart in back HEATING ELEMENT 1 Disconnect...
Страница 15: ...all access cover 13 Fill tank and check around element for any leaks THERMOSTAT 1 Disconnect power from unit 2 Remove access cover and locate thermostat 3 Disconnect the two 2 control wires Wires Capi...
Страница 16: ...e to relieve pressure in tank 4 Disconnect overflow piping 5 Unscrew relief valve remove assembly and replace with new one 6 Connect overflow piping 7 Turn on incoming water supply and check for leaks...
Страница 17: ...the Company TANK REPLACEMENT POLICY TEN YEARS This section outlines the ten year limited replacement policy for tanks that fail due to the corrosive effects of water Duration Ten years from date of or...
Страница 18: ...y term of this agreement and will not extend beyond that one year limitation The parts of this warranty including the incorporated users manual that speaks specifically to terms and condition are deem...
Страница 19: ...NOTES 19...
Страница 20: ...P O BOX 288 STRATFORD CT 06615 0288 PHONE 203 378 2659 FAX 203 378 3593 INTERNET http www hubbellheaters com 20...