Block Diagram

Plug 

P1

 on the back of the Base-24 PCBA plugs into a socket in an enclosure connected to the system

cable, picking up the Page/Party

®

 lines and ac power.  Connector 

J6

 on the Base-24 PCBA connects ac

power to the Bias Power Supply PCBA and re5 V dc and +/-15 V dc in return.

The Base-24 PCBA uses the bias supplies and also passes them (as well as control, monitoring, and line
signals) to the FSK Modem and Handset Amplifier PCBAs via 

J1

, a 24-pin stacking connector.

Connector 

J2

 on the Base-24 PCBA connects the speaker transformer for the station’s speaker, and 

J3

connects optional external devices.

The Handset Amplifier PCBA connects to the handset and the hookswitch via spade terminal connectors

E1

 to 

E7

.

Figure 3.  Remote Subset Amplifier Block Diagram

Содержание Gai-Tronics SmartSeries 723-801

Страница 1: ...egral part of GAI Tronics desktop desk edge and flush mount stations It has been designed to be remotely mounted with the enclosure allowing the associated subsets to be mounted on a desktop on the ed...

Страница 2: ...problems Monitors and reports problems with handset amplifier the speaker amplifier and speaker voice coil to the MCU Supervises the local speaker desk edge and flush mount stations only Monitors and...

Страница 3: ...components are described below ExternalComponents User Level Adjustment This assembly contains a User Level Adjustment that is accessible beneath the nameplate on the front panel See Figure 1 The User...

Страница 4: ...d to the Base 24 PCBA The FSK Modem PCBA enables data to be transferred between the station s CPU and the control unit Handset Amplifier PCBA This assembly is affixed to the FSK Modem PCBA The Handset...

Страница 5: ...s ac power to the Bias Power Supply PCBA and receives 5 V dc and 15 V dc in return The Base 24 PCBA uses the bias supplies and also passes them as well as control monitoring and line signals to the FS...

Страница 6: ...rican Zettler AZ830 4C 12DSEA or Aromat DS4E S DC12V The installation procedure for the Model 723 801 SmartSeries Remote Smart Amplifier is as follows 1 If your enclosure contains an I2 C Module optio...

Страница 7: ...ivot the nameplate clockwise into position then tighten the 2 screws Offset Level setting This setting determines the speaker output level above ambient noise The amplifier automatically adjusts the s...

Страница 8: ...e 2 Pivot the nameplate counterclockwise exposing the access hole A guide behind the access hole helps direct the screwdriver to the USER ADJ control 3 Have an assistant page from a station that meets...

Страница 9: ...tem configuration It is recommended that this address be marked on the enclosure for future reference 4 Plug the amplifier into the enclosure 5 Setting the station address to the correct value and re...

Страница 10: ...adjustments To access the controls perform the following steps 1 Loosen the 4 captive screws that secure the front panel 2 Remove the assembly from the enclosure If the enclosure is equipped with an...

Страница 11: ...ESET on the Base 24 PCBA to reset the central processing unit CPU Other Controls This assembly contains the following additional controls These controls affect system performance therefore only qualif...

Страница 12: ...el as appropriate Refer to the Adjustments section of this document Incoming handset speech level needs adjustment Use the RCVR VOL control to adjust the handset receiver volume Refer to the Adjustmen...

Страница 13: ...on Polled Device Paging Pressbar Depressed Cause The station has been in page mode longer than the configured page limit Effect Station page is cut off When the pressbar is released a restore message...

Страница 14: ...es communication with the station This may occur if there is a fault in the page line if the station is powered down or if there is some fatal malfunction within the station Effect The MCU continues t...

Страница 15: ...Point 35 dB SPL adjustable via configuration Note The measured SPL varies for each speaker type Recommended Environment Greater than 50 dB SPL Data Communications FSK Output to Line 0 7 VRMS 2 Vp p i...

Страница 16: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Отзывы: